To repair a small electrical motor that has been submerged in saltwater, you should _____________. A. wash it with fresh water and apply an external source of heat B. renew the windings C. send it ashore to an approved service facility D. rinse all electrical parts with a carbon tetrachloride cleaning solvent and then blow dry the motor with compressed air

1 Answer

Answer :

Answer: A

Related questions

Description : If a small electric motor has been submerged in saltwater for a short period of time, you should _____________. A. send it ashore for rewinding B. rinse it with warm freshwater and bake it dry ... and bake with internal heat D. clean it with carbon tetrachloride and blow it out with compressed air

Last Answer : Answer: B

Description : Which of the following statements is true concerning the cleaning of electrical contacts? A. Compressed air should be used to blow out metallic dust. B. Magnetic brushes should be used to remove ... contact resistance. D. Delicate parts should be cleaned with a brush and an approved safety solvent.

Last Answer : Answer: D

Description : Which of the following represents the accepted method of cleaning dust and foreign particles from electrical equipment while limiting damage to electric components? A. Carefully wiping off the components ... the components. D. Using carbon tetrachloride as a cleaning solvent to clean the components.

Last Answer : Answer: C

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : Which of the following procedures should be used to maintain a large electric motor during periods of inactivity? A. A thin layer of air-drying varnish should be applied on the windings. B. ... periodically to remove carbon dust. D. Space heaters should be used to prevent condensation of moisture.

Last Answer : Answer: D

Description : Grease coatings on electrical contact surfaces increase contact resistance and should be removed with a/an _______________. A. small wire brush B. compressed air jet C. clean dry cloth D. 10% solution carbon solvent and water

Last Answer : Answer: C

Description : Which of the following statements, concerning the general maintenance of a brushless generator, is correct? A. Paint should be applied to insulating surfaces on an annual basis. B. Alcohol should be used to ... . D. Accessible generator parts should be wiped with a clean dry rag on a periodic basis.

Last Answer : Answer: D

Description : If deck machinery is expected to be idle for an extended period of time you should____________. A. have electrical safety gloves available in case of electrical shock before running B. perform ... run at regular intervals to inusre correct operation and to renew the internal coating of lubrication

Last Answer : Answer: D

Description : Which of the listed precautions should be taken when cleaning the internals of a motor with compressed air? A. Open the machine on both ends so as to allow the air and dust to escape. B. Be certain that the ... panel. C. Be certain that the air is clean and as dry as possible. D. All of the above.

Last Answer : Answer: D

Description : A fuse will 'blow' if _____________. A. an electric motor is stopped suddenly by opening a switch B. the flow of current to the protection device is reversed C. the electrical current exceeds the rated value of the fuse D. unequal resistors are connected in parallel

Last Answer : Answer: C

Description : The energy consumed by an AC motor, as strictly reactive power, is _____________. A. used to do mechanical work B. used to establish the magnetic field of the motor C. lost as heat generated by the windings D. lost in doing work to turn the motor itself

Last Answer : Answer: B

Description : The reactive power drawn by a motor from an AC generator is the power which is _____________. A. used to establish the magnetic field of the motor B. lost in overcoming friction in the ... by current flow through the windings D. transmitted directly through the rotor shaft to perform useful work

Last Answer : Answer: A

Description : Consider the following chemicals: 1. Benzene 2. Carbon tetrachloride 3. Sodium carbonate 4. Trichloroethylene The chemicals used as dry cleaning agent(s) is/are (a) 1 only (b) 2 only (c) 1, 2 and 4 only (d) 1, 2, 3 and 4

Last Answer : Ans:(c)

Description : Motor name plate data includes '°°C rise'. This indicates the _____________. A. actual running temperature of the winding from no load to full load B. permissible temperature rise ... above normal full load operating temperature D. maximum allowable temperature rise for continuous no load service

Last Answer : Answer: B

Description : Which of the listed precautions should be observed before spraying liquid solvent on the insulation of an electric motor? A. Slow the motor down to low speed. B. Disconnect the motor from the power source. C. Secure all ventilation in the area. D. Preheat the insulation to assist in cleaning.

Last Answer : Answer: B

Description : Compressed air should not be used to clean motor controller equipment because ________________. A. it may force metallic particles into coil insulation B. the surrounding area may need additional cleaning C. the air blast dries out insulation quickly D. a mask and respirator would be required

Last Answer : Answer: A

Description : While starting a main propulsion synchronous motor, the ammeter pegs out at maximum and then returns to the proper value after synchronization. This indicates the _____________. A. motor has started ... field windings are grounded C. slip rings are dirty D. power transmission cables are grounded

Last Answer : Answer: A

Description : Moisture absorbed in the windings or condensed on the surface of electrical machinery insulation ________. A. is good for long term preserving since most insulation is organic and contains some amount B. ... D. reduces the amount of current supplied or drawn by the machine so horsepower is limited

Last Answer : Answer: B

Description : In the illustrated test, if the lamp fails to light on any of the three windings then _________. EL-0027 A. all three windings are grounded and the motor should be sent out for repair B. ... the motor controller and the controller should be checked D. the test should be redone at a higher voltage

Last Answer : Answer: C

Description : The commonly used solvent in supercritical extraction is (A) Methyl ethyl ketone (B) Water (C) Carbon tetrachloride (D) Carbon dioxide

Last Answer : (D) Carbon dioxide

Description : . In which solvent are alkenes most soluble? (a) water (b) ethyl alcohol (c) ammonia (d) carbon tetrachloride

Last Answer : carbon tetrachloride

Description : In an alternating current electrical system, a low system power factor is a direct sign of _____________. A. wasted energy B. efficient operation C. a short in the exciter field windings D. an excessive number of minor system grounds

Last Answer : Answer: A

Description : The greatest detrimental effect on idle electrical equipment, such as cargo pump motors, is the _____________. A. loss of residual magnetism B. absorption of moisture in the insulation C. insulation varnish flaking D. dirt collecting on the windings

Last Answer : Answer: B

Description : Unnecessary and frequent applications of varnish to the generator windings to repair defective insulation will result in ____________. A. heavy coatings of varnish interfering with heat dissipation B. ... of the rectifier assembly D. a built-up of varnish without changing generator operation

Last Answer : Answer: A

Description : Do pearls wash ashore?

Last Answer : Pearls are delicate things. Any pearls rolling around loose on the ocean floor will be scuffed and marred to the point they have no value.

Description : The proper way to apply plastic electrical tape to an electric cable splice is to _____________. A. apply tape to the braided cover, but avoid touching it B. wind the tape so that each turn overlaps ... tape in one non-overlapping layer only D. heat the tape with a soldering iron for good bonding

Last Answer : Answer: B

Description : The first step in decontamination is a. Removal of the patient's clothing and jewelry and then rinsing the patient with water. To be effective, decontamination must include a minimum of two steps. The ... the patient with water. The second step consists of a thorough soap and water wash and rinse.

Last Answer : a. Removal of the patient's clothing and jewelry and then rinsing the patient with water. To be effective, decontamination must include a minimum of two steps. The first step is removal of the patient ... the patient with water. The second step consists of a thorough soap and water wash and rinse.

Description : The speed of a multi-speed, squirrel-cage, induction motor operating in a fixed frequency system can be changed by _____________. A. reconnecting stator windings for different numbers of poles B. ... sequence of the applied voltage D. reconnecting the stator so that no poles have the same polarity

Last Answer : Answer: A

Description : In a series wound motor, the current passing through the field windings is also passing through the _____________. A. armature B. shunt field C. reactance comparator D. laminations

Last Answer : Answer: A

Description : The speed of a squirrel-cage motor is usually changed by _____________. A. varying the frequency to the machine B. adding resistance in series with the stator windings C. adding resistance in parallel with the stator windings D. changing the number of connected poles in the stator

Last Answer : Answer: D

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : The function of amortisseur, or damper windings in a synchronous motor is to _____________. A. eliminate slippage B. provide excitation C. provide starting torque D. increase efficiency

Last Answer : Answer: C

Description : The function of damper windings in a synchronous motor is to _____________. A. eliminate slippage B. provide excitation C. provide starting torque D. increase efficiency

Last Answer : Answer: C

Description : Amortisseur windings are installed in a synchronous motor to _____________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : In an AC generator, direct current from a separate source is passed through the windings of the rotor _____________. A. by means of slip rings and brushes B. by means of a commutator C. by means of rotating bar magnet D. to minimize the danger of arc over

Last Answer : Answer: A

Description : Chemistry question. Can you wash your clothes with bleach and then use vinegar in the rinse cycle safely?

Last Answer : I can’t imagine you could without smelling like something awful…..

Description : Before reassembling any machinery, you should _____________. A. replace all bearings regardless of length of service B. apply a heavy coat of oil to all mating surfaces C. clean any corroded surfaces and file all burrs smooth D. coat all parts with alemite grease

Last Answer : Answer: C

Description : The illustrated motor fails to start and gives a loud hum when the start button is depressed, your first action should be to __________. EL-0007 A. disassemble the motor to fix the centrifical ... D. hold the 'M' contactor closed by hand while wearing electrical safety gloves to get motor started

Last Answer : Answer: B

Description : A capacitor discolored due to excessive heat should be _____________. A. calibrated using a capactance wheatstone bridge B. replaced and the reason for the overheating found C. cooled with a spray ... purpose D. resoldered with care taken to insure that the origional cold solder joint is repaired

Last Answer : Answer: B

Description : The electrical energy necessary to transmit a person's voice over a sound-powered telephone circuit is obtained from _____________. A. dry cell batteries B. the ship's service switchboard C. the emergency switchboard D. the speaker's voice

Last Answer : Answer: D

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : For routine cleaning of a commutator, you should apply _____________. A. course sandpaper in a slow back and forth motion across the commutator slots B. an emery cloth parallel to the axis of the machine C. a canvas wiper to the machine while running D. cotton swabs between the commutator bars

Last Answer : Answer: C

Description : Before working on an electric cargo winch master switch or controller, you should _____________. A. spray the gasket surface with a solvent B. drain condensate from the box C. open the circuit breaker in the power supply and tag D. heat the switch box to remove any moisture

Last Answer : Answer: C

Description : After swimming in a pool, lake or ocean, do you wash your bathing suit in the washing machine or just rinse it out in the sink?

Last Answer : Machine and dryer. I get my bikinis at Target – no need to treat them special.

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : Cleaning of electrical insulation should be _____________. A. done every six months B. accomplished every 12 months C. determined by need and not the calendar D. performed whenever the electrician is not otherwise busy

Last Answer : Answer: C

Description : If you have a solution of saltwater. In this solution what is the solvent and what is the solute?

Last Answer : Water is a solvent and salt is a solute and the solution with that is ocean water (salt water).