If we change the excitation of synchronous machine will it affect on motor speed?

105 views

1 Answer

Answer :

No, If we change the excitation of synchronous machine it will not affect on motor speed.

Like 0 like

Please log in or register to answer this question.

Related Questions


If we change the excitation of synchronous machine will it affect on power factor?
Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Show More

123 views 1 answer








Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Show More

196 views 1 answer







what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?
Last Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

Show More

367 views 1 answer








Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Show More

110 views 1 answer







The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.
Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Show More

550 views 1 answer








Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

Show More

122 views 1 answer







Synchronous motor always runs at which speed?
Last Answer : Synchronous motor always runs at synchronous speed.

Show More

90 views 1 answer








Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Show More

111 views 1 answer








Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Show More

222 views 1 answer








Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Show More

130 views 1 answer







Why the speed of synchronous motor is constant?

Show More

67 views 0 answers







The synchronous speed of an 8 pole induction motor supplied power from a 50 Hz source will be ?
Last Answer : Ns         equals        f/pair pole 50/4      - 12.5

Show More

202 views 2 answers







In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading
Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Show More

130 views 1 answer








Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Show More

95 views 1 answer








Last Answer : A synchronous machine with low value of short-circuit ratio has lower stability limit.

Show More

103 views 1 answer







V - curve of synchronous machine shows the relation between?
Last Answer : V - curve of synchronous machine shows the relation between AC armature current and DC field current.

Show More

80 views 1 answer







Why synchronous machine is called doubly excited machine?
Last Answer : Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

Show More

3.3k views 2 answers







Which machine is the exciter of synchronous machine?
Last Answer : DC shunt machine is the exciter of synchronous machine.

Show More

70 views 1 answer








Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Show More

168 views 1 answer







How can we reverse the direction of rotation of synchronous motor?
Last Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

Show More

305 views 1 answer







Can we use the synchronous motor as the synchronous capacitor?
Last Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

Show More

91 views 1 answer








Last Answer : Slip-rings in a synchronous motor carry direct current.

Show More

99 views 1 answer








Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Show More

73 views 1 answer







A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?
Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Show More

169 views 1 answer








Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

Show More

114 views 1 answer








Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

Show More

254 views 1 answer








Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

Show More

138 views 1 answer








Last Answer :  The size of a synchronous motor decreases with the increase in flux density.

Show More

196 views 1 answer








Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Show More

151 views 1 answer







The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?
Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Show More

302 views 1 answer








Last Answer : The construction of a synchronous motor resembles an alternator.

Show More

83 views 1 answer








Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Show More

258 views 1 answer







The maximum torque which a synchronous motor will develop at rest for any angular position of the rotor, at rated stator supply voltage and frequency, is known as?

Show More

106 views 0 answers








Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

Show More

218 views 1 answer








Last Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Show More

116 views 1 answer








Last Answer : The armature current of the synchronous motor has large values for low and high excitation.

Show More

107 views 1 answer







Which motor have more efficiency, synchronous motor or induction motor?
Last Answer : Synchronous motor has more efficiency.

Show More

93 views 1 answer







What is the maximum value of torque angle in synchronous motor?
Last Answer : The maximum value of torque angle in synchronous motor is 90 degrees electrical.

Show More

1.5k views 1 answer







If the load of the normally excited synchronous motor is increased the power factor will?
Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Show More

150 views 1 answer







Hunting in synchronous motor cannot be due to?
Last Answer : Hunting in synchronous motor cannot be due to windage friction.

Show More

97 views 1 answer







The synchronous motor which works on leading power factor and does not drive any mechanical load is called?
Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Show More

163 views 1 answer







The damping winding in synchronous motor is generally used to?
Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Show More

157 views 1 answer







If the field of synchronous motor is under excited, power factor will be?
Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Show More

483 views 1 answer







An unexcited single phase synchronous motor is ?
Last Answer : An unexcited single-phase synchronous motor is reluctance motor.

Show More

160 views 1 answer







A synchronous motor can be made self starting by providing?
Last Answer : A synchronous motor can be made self-starting by providing damper bar.

Show More

131 views 1 answer







In a synchronous motor which losses varies with load?
Last Answer : In a synchronous motor, copper losses varies with load.

Show More

102 views 1 answer







The back emf of synchronous motor depends on?
Last Answer : The back emf of synchronous motor depends on load angle.

Show More

65 views 1 answer







The synchronous motor will develop maximum power when the load angle is?
Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Show More

226 views 1 answer







Three phase synchronous motor will have how many sliprings?
Last Answer : Three phase synchronous motor will have two sliprings.

Show More

95 views 1 answer







In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator
Last Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Show More

603 views 1 answer






Show More⇦ PreviousNext ⇨