Please Log in or Register for more.


87 views

1 Answer

Answer :

In a D.C. shunt motor, speed is independent of armature current.

Like 0 like

Please log in or register to answer this question.

Related Questions


A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be
Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Show More

483 views 1 answer








Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Show More

135 views 1 answer








Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Show More

142 views 1 answer







Why does the speed of a DC shunt motor decrease as the load increases?
Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Show More

2.7k views 1 answer








Last Answer : If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.

Show More

203 views 1 answer








Last Answer : The speed of a D.C. shunt motor more than its full-load speed can be obtained by decreasing the field current.

Show More

148 views 1 answer








Last Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Show More

250 views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

332 views 1 answer








Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Show More

168 views 1 answer








Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Show More

210 views 1 answer








Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Show More

367 views 1 answer








Last Answer : If the field of a D.C. shunt motor gets opened while motor is running the motor will attain dangerously high speed.

Show More

135 views 1 answer







If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.
Last Answer : increases

Show More

2.8k views 4 answers







DC shunt motor
Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Show More

140 views 2 answers







State any four applications of DC shunt motor.
Last Answer : Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans

Show More

115 views 2 answers








Last Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Show More

158 views 1 answer







The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above
Last Answer : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Show More

390 views 1 answer








Last Answer : The speed of a D.C. series motor is inversely proportional to the armature current.

Show More

114 views 1 answer







What are the speed control methods of dc motor?
Last Answer : Field control of DC motor Armature control of DC motor

Show More

254 views 2 answers








Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Show More

324 views 1 answer








Last Answer : In D.C. shunt motors as load is reduced the speed will remain almost constant.

Show More

145 views 1 answer







The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α
Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Show More

150 views 1 answer








Last Answer : In a manual shunt motor starter over load relay is connected in series and no volt relay in parallel with the load.

Show More

76 views 1 answer








Last Answer : In a differentially compounded D.C. motor, if shunt field suddenly opens the motor will first stop and then run in opposite direction as series motor.

Show More

94 views 1 answer








Last Answer : If a D.C. shunt motor is working at no load and if shunt field circuit suddenly opens this will result in excessive speed, possibly destroying armature due to excessive centrifugal stresses.

Show More

122 views 1 answer








Last Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.

Show More

75 views 1 answer








Last Answer : D.C. shunt motors are used for driving machine tools.

Show More

85 views 1 answer







The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above
Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Show More

235 views 1 answer







The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm
Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

Show More

152 views 1 answer








Last Answer : In variable speed motor a weaker commutating field is needed at low speed than at high speed.

Show More

62 views 1 answer








Last Answer : Series motor has the poorest speed control.

Show More

103 views 1 answer








Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Show More

164 views 1 answer








Last Answer : The speed of a universal motor is usually reduced by using gearing.

Show More

115 views 1 answer








Last Answer : Speed control of a universal motor is achieved by varying field flux with tapped field windings, connecting rheostat in series, applying variable voltage by means of silicon controlled rectifier, applying variable voltage by means of variable auto-transformer.

Show More

100 views 1 answer








Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Show More

111 views 1 answer








Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Show More

222 views 1 answer








Last Answer : The speed/load characteristics of a universal motor is same as that of D.C. series motor.

Show More

175 views 1 answer








Last Answer : Speed torque characteristic of a repulsion induction motor is similar to that of a D.C. compound motor.

Show More

165 views 1 answer








Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Show More

130 views 1 answer








Last Answer : The speed control of universal motor used for sewing machines is by varying the resistance.

Show More

105 views 1 answer







Why the speed of synchronous motor is constant?

Show More

67 views 0 answers







speed control methods of three phase induction motor?
Last Answer : Speed control of three phase induction motor

Show More

364 views 2 answers








Last Answer : In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed by the motor will remain unchanged.

Show More

228 views 1 answer







The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover
Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Show More

355 views 2 answers








Last Answer : When two D.C. series motors are connected in parallel, the resultant speed is normal speed.

Show More

379 views 1 answer







Describe the reason of using dc series motor for electric trains.
Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

Show More

142 views 1 answer







In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :
Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

Show More

109 views 1 answer







The function of a brush and commutator arrangement in a dc motor is to  (1) produce unidirectional torque (2) produce unidirectional current in the armature (3) help in changing the direction of rotation of the armature (4) reduce sparking
Last Answer : The function of a brush and commutator arrangement in a dc motor is to produce unidirectional torque

Show More

2.5k views 1 answer








Last Answer : If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient temperature, then the motor is to be derated by a factor recommended by manufacturer and select the next higher H.P. motor.

Show More

97 views 1 answer








Last Answer : At the instant of starting when a D.C. motor is put on supply, it behaves like a low resistance circuit.

Show More

130 views 1 answer






Show More⇦ PreviousNext ⇨