Dynamometer type moving coil instruments are provided with pneumatic damping

Related questions

Description : Which of the following instruments have least torque/weight ratio: a) Dynamometer type b) PMMC c) Attraction type moving iron d) Repulsion type moving iron

Last Answer : Ans: A

Description : Moving coil in dynamometer wattmeter connected a) In series with fixed coil b) Across supply c) In series with load d) Across load

Last Answer : Ans: Across supply

Description :  Moving coil in dynamometer wattmeter connected : - a) in series with fixed coil b) across supply c) in series with load d) across load

Last Answer : Moving coil in dynamometer wattmeter connected : - across supply

Last Answer : The resistance in the circuit of the moving coil of a dynamometer wattmeter should be high.

Description : State the material used for moving coil and former for PMMC instruments. 

Last Answer : Material Used for Moving Coil and Former for PMMC Instruments:  Material used for moving coil: Copper  Material used for Former: Aluminium

Description :  In dynamometer type of wattmeter, which of the coil is split up into two parts?

Last Answer :  In dynamometer type of wattmeter, which of the coil is split up into two parts?  current coil

Description : The pressure coil of a dynamometer type wattmeter is  A) Highly inductive B) Highly resistive C) Purely resistive D) Purely inductive

Last Answer : highly resistive

Description : Which of the instruments listed is used to check insulation resistance? A. Magneto B. Megohmmeter C. Dynamometer D. Rheostat

Last Answer : Answer: B

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : Current range extension in moving coil instruments can be achieved by placing a ___ in shunt with the instrument.

Last Answer : low resistance resistor

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Last Answer : In a dynamo-meter type of moving coil instrument a swamping resistance is provided inorder to: Provide equal time constant for moving coil and fixed coil, when used for ac measurement

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Description : To limit the current flow through a DC voltmeter to as low a value as possible, the moving coil circuit is provided with a/an _____________. A. high series resistance B. high parallel resistance C. series inductor D. external shunt

Last Answer : Answer: A

Last Answer : In moving coil meters, damping is provided by eddy current disk.

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : State the effects of errors in dynamometer type wattmeter due to i) pc- inductance ii) pc- capacitance iii) mutual inductance iv) Connection.

Last Answer : Errors in wattmeter:  i) pc - inductance: Pressure coil inductance causes wattmeter to read more power than actual .  ii) pc-capacitance: The wattmeter reads less power.  iii) ... iv) Connection: In uncompensated wattmeter , the reading of wattmeter includes the powerloss in coils. 

Description : State any four errors that occur in dynamometer type wattmeter

Last Answer : Errors that occur in dynamometer type wattmeter: 1. Errors due to method of connection. 2. Error due to pressure coil inductance. 3. Error due to pressure coil Capacitance. 4. Error due to mutual ... Error due to eddy currents. 7. Temperature error. 8. Error due to vibration of moving system

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Description : With neat diagram explain constructional details of dynamometer type wattmeter.

Last Answer : Working Principle of Wattmeter: It consists of two stationary coils, called current coils and one moving coil, called voltage or potential coil. The moving coil is mounted on the spindle, in the gap ... experiences a force and tends to move in the direction as per Fleming's left hand rule. 

Description : Consider the following statements with regard to Moving Iron (MI) instruments :  1. These instruments possess high operating torque.  2. These instruments can be used in ac and dc circuits.  3. Power consumption in these instruments ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Last Answer : Consider the following statements with regard to Moving Iron (MI) instruments :  1. These instruments possess high operating torque.  2. These instruments can be used in ac and dc circuits.  3. Power consumption in these ... 1 and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Description : In moving iron instruments, eddy current damping cannot be used as  (a) They have a strong operating magnetic, field (b) They are not normally used in vertical position (c) They ... of a permanent magnet required for eddy current damping would distort the existing weak operating magnetic field

Last Answer : In moving iron instruments, eddy current damping cannot be used as The introduction of a permanent magnet required for eddy current damping would distort the existing weak operating magnetic field

Description : Moving iron instruments can be used for measuring (1) Direct currents and voltages (2) Radio frequency currents (3) A.C currents and voltages (4) Both (a) and (c)

Last Answer : moving iron instruments areused to measure A.C curents &  voltages

Description : Which of the instruments listed could be use to locate a grounded field coil in a synchronous motor? A. Ammeter B. Voltmeter C. Megohmmeter D. Frequency meter

Last Answer : Answer: C

Description : Which of the listed instruments can be best used to locate a grounded field coil in a synchronous motor? A. Frequency meter B. Megohmmeter C. Voltmeter D. Multimeter

Last Answer : Answer: B

Description : Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

Last Answer : (i) Material used for Moving coil: Copper, Aluminum( some times)  (ii) Permanent magnets are made of special alloys such as :  Aluminum-Nickel-Cobalt (Alnicos)  Strontium-Iron  Neodymium-Iron-Boron  Samarium-Cobalt.

Description : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is

Last Answer : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is 2.5 milliOhm

Last Answer : The coil of a moving coil meter is would on An aluminium frame.

Description : The draft of a trailed type implement can be measured using a) Brake dynamometer b) Torque meter c) Tension dynamometer d) Dial gauge Ans. c

Last Answer : Ans. c

Description : Dynamometer type instrument can be used for

Last Answer : both dc and ac works

Description : power of absorbing type hydraulic dynamometer varies as a) cube of rpm b) fifth power of the diameter c) none of the above d) both (a) and (b)

Last Answer : d) both (a) and (b)

Description :  In an energymeter which coil carries the current proportional to supply voltage _____. 

Last Answer :  In an energymeter which coil carries the current proportional to supply voltage Pressure coil. 

Last Answer : The series magnet of a single phase Energy meter consists of coil of thick wire of few turns.

Last Answer : In the majority of instruments, damping is provided by eddy currents.

Description : What does a dynamometer measure?

Last Answer : A dynamometer is used to measure force, torque or power of a engine. A dynamometer also can measure the torque and power needed to power a given driven machine.

Description : Do I need any special training to use a dynamometer?

Last Answer : Yoy may be able to figure it out but I would not trust it. I would begin looking online or asking someone who knows about dynamometers for help. If you can do these two options you might just need to as your boss for assistance before next week.

Description : Soil strength is determined by (a) Penetrometer (b) Micrometer (c) Hydrometer (d) Dynamometer

Last Answer : (a) Penetrometer

Description : A dynamometer instrument is mainly used as a/an

Last Answer : wattmeter

Description : Where can we used the dynamometer?

Last Answer : dc and ac

Description : For a dynamometer to be able to measure high current, a ___ should be used.

Last Answer : current transformer

Description : Soil strength is determined by: A. penetrometer B. micrometer C. hydrometer D. dynamometer

Last Answer : D. dynamometer

Description : Which one is a transmission dynamometer a) Torsion dynamometer b) Froues hydraulic dynamometer c) Belr dynamometer d) Proney brake dynamometer

Last Answer : a) Torsion dynamometer

Description : Explain the working principle of the following dynamometers with suitable sketches, if necessary: (i) Hydraulic Dynamometer. (ii) Eddy Current Dynamometer.

Last Answer : (i) Hydraulic Dynamometer: In principle, hydraulic dynamometer construction is similar to that of a fluid flywheel. Hydraulic dynamometer consists of an impeller or inner rotating member coupled to the output shaft ... Eddy current oppose the rotor motion thus loading the engine.

Description : Describe the working of electrical dynamometer

Last Answer : Electric Dynamometer:- These may be either the i) Swinging field type  ii) Eddy current type. Working principle of eddy current dynamometer:  Figure: Working principle of Eddy ... the help of a movement arm. The load is controlled by regulating the current in the electromagnets. 

Last Answer : A dynamometer wattmeter can be used for both D.C. and A.C.

Description : A moving system force in an analog instruments which causes the moving system to deflect from its zero position.

Last Answer : deflecting force

Description : A moving system force in analog instruments which ensures that the deflection of the pointer for a given value of measured quantity always has the same value

Last Answer : controlling force

Description : Which of the following forces does not act on the moving systems of analog instruments?

Last Answer : an electrostatic force

Description : Horizontally mounted moving iron instruments use   (a) Eddy current damping (b) Electromagnetic damping (c) Fluid friction damping (d) Air friction damping

Last Answer : Horizontally mounted moving iron instruments use Air friction damping

Last Answer : Moving iron and PMMC instruments can be distinguished from each other by looking at: Scale