One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

1 Answer

Answer :

One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is 0.8

Related questions

Description : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

Last Answer : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be 13.80 rpm

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : An energy meter has a constant of 600 rev/kWh. If the meter makes 10 revolutions in 20 s, what is the load in kW?  (A) 0.75 kW (B) 1.5 kW (C) 3 kW (D) 6 kW 

Last Answer : 1.5 kW 

Description : A meter whose constant is 600 revolutions/kWh makes 5 revolutions in 20 seconds. Calculate the load in kW. (1) 0.5 kW (2) 1 kW (3) 1.5 kW (4) 2 kW  

Last Answer : 1.5 kW 

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is  (A) 2.43 A (B) 1.65 A (C) 1.22 A (D) 1.0 A

Last Answer : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is 1.0 A

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : What will be the frequency of a three-phase, six pole, AC generator operating at 1800 revolutions per minute? A. 60 hertz B. 90 hertz C. 120 hertz D. 180 hertz

Last Answer : Answer: B

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be

Last Answer : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be 115 V.

Description : a single phase full wave midpoint thyristor converter uses a 230/200V transformer with centre tap on the secondary side. The P.I.V per thyristor is   (A) 100V (B)141.4V (C)200V (D)282.8V

Last Answer : d

Description : The current coil of a single-phase energy meter is wound on (a) One limb of the laminated core (b) Both the limbs of the laminated core with same number of turns (c) Both the limbs of the laminated core with different number of turns (d) The centre of the limb on the laminated core

Last Answer : The current coil of a single-phase energy meter is wound on Both the limbs of the laminated core with same number of turns

Description : A single phase energy meter has a constant of 1200 revolution/kWh. When a load of 200 W is connected, the disc rotates at 4.2 revolutions per min. If the load is on for 10 hours, the meter records an excess of   (a) 0.1 kWh (b) 0.2 kWh (c) 1.0 kWh (d) 2.0 kWh 

Last Answer : 2

Last Answer : The series magnet of a single phase Energy meter consists of coil of thick wire of few turns.

Description : What is the frequency of an alternator which has 2 poles and makes 3600 revolutions per minute? A) 3600 HZ B) 60 Hz C) 120 Hz D) None of these

Last Answer : What is the frequency of an alternator which has 2 poles and makes 3600 revolutions per minute? A) 3600 HZ B) 60 Hz C) 120 Hz D) None of these

Description : Three 60 W bulbs are in parallel across the 230 V power line. If one bulb burns out

Last Answer : Three 60 W bulbs are in parallel across the 230 V power line. If one bulb burns out the other two bulbs will remain glowing

Description : A d.c. voltage of 230 V is imposed on an unloaded 230 V, 50 Hz transformer, it will (A) give high secondary voltage (B) burn out (C) give secondary voltage as per k (D) None of these

Last Answer : A d.c. voltage of 230 V is imposed on an unloaded 230 V, 50 Hz transformer, it will burn out

Last Answer : The resistance of a 230 V, 100 W lamp is 529 Ω.

Last Answer : A heater is rated as 230 V, 10 kW, A.C. The value 230 V refers to r.m.s. voltage.

Description : The torque of 50 Nm is applied on the wheel operating a valve. If the wheel is rotated through two revolutions, work done in Newton-metres is given by a.628 b.107 dynes c.314 d.25 e.100

Last Answer : a. 628

Description : The difference between the synchronous speed of an induction machine and its operating speed (slip) may be correctly expressed _____________. A. as a percent of synchronous speed B. as a decimal fraction of synchronous speed C. directly in revolutions per minute D. as all of the above

Last Answer : Answer: A

Description : Explain the calibration of single phase electronic energy meter using direct loading.

Last Answer : Calibration of Single-phase Electronic Energy Meter by Direct Loading Method: The following figure shows the arrangement of calibration for single phase electronic energy meter. A phase shifter is connected for ... are taken for different values of current at different power factors. 

Description : Describe with block diagram; the construction of single phase electronic energy meter. 

Last Answer : Construction of Single Phase Electronic Energy Meter: 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the ... The ADC converts the square wave frequency analog output to display the energy in Watt-hour.

Description : List the errors occuring in single phase electronic energy meter.

Last Answer : Errors in Single Phase Electronic Energy Meter: 1) Error due to wrong sensor opeartion. 2) Error due to temperature. 3) Error due to wrong CT opeartion. 4) Error due to wrong PT opeartion. 5 ... of scaling network. 6) Error due to wrong ADC opeartion. 7) Error due to wrong Display. 

Description : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by   (a) 90o (b) 0o (c) 45o (d) 60o

Last Answer : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by 90o

Description : How much distance (in cm) will the bicycle shown below travel, if the pedal makes 1.5 revolutions? (Assume π = 22/7). 

Last Answer : 330

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter would then read ____________. A. 181.4 KW B. 186.8 KW C. 194.2 KW D. 201.4 KW

Last Answer : Answer: B

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter reading would increase by ___ A. 17.8 KW B. 23.2 KW C. 30.6 KW D. 37.8 KW

Last Answer : Answer: B

Description : Draw a neat sketch of 1-ph induction type energy meter and write operating principle of it. 

Last Answer : Operating Principal:- The disc is placed between the two-flux due to pressure coil and flux due to current coil, which will set up torque on the disc which is proportional to power causing the ... is proportional to voltage, the second carries a current coil so its flux is proportional to current.

Description : In a hydrogen atom, the electron makes about `0.6xx10^(16)` revolutions per second around the nucleus. Determine the average current at any point on t

Last Answer : In a hydrogen atom, the electron makes about `0.6xx10^(16)` revolutions per second around the nucleus. ... at any point on the orbit of the electron.

Description : A wheel has a diameter of 21 inches. How far does it travel if it makes 30 complete revolutions?

Last Answer : I need help

Description : Current in a 60 W light bulb when it is connected to a 230 V power supply is A. 0.26 A B. 1.5 A C. 2.6 A D. 3.9 A

Last Answer : 0.26 A

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Description : Two taps M and N can alone fill a tank in 80 minutes and 120 minutes respectively. But due to a leakage of tank, it took 12 more minutes to fill the tank. In how many hours, the leak can alone empty the full tank? A) 240 B) 230 C) 248 D) 256

Last Answer : A A and B can fill tank in (1/80 + 1/120) = 1/48 so 48minutes But it took 12 more minutes, this means the tank got full in 48+12= 60 minutes So (1/80 + 1/120 – 1/x) = 1/60 1/X=1/80+1/120-1/60 Solve, x = 240

Description : A process electric heater is taking an hour to reach the desired temperature while operating at 440 V. It will take ------- hours to reach the same temperature if the supply voltage is reduced to 220 V. a) 2 b) 3 c) 4 d) 5

Last Answer : c) 4

Description : A filament bulb `(500 W, 100 V)` is to be used in a `230 V` main supply. When a resistance `R` is connected in series, it works perfectly and the bulb

Last Answer : A filament bulb `(500 W, 100 V)` is to be used in a `230 V` main supply. When a resistance `R` is ... Omega` B. `46 Omega` C. `26Omega` D. `13 Omega`

Description : Ionisation potential applied across the electrodes of electrostatic tar precipitator is around (A) 230 V AC (B) 60 KV AC (C) 230 V DC (D) 60 KV DC

Last Answer : (D) 60 KV DC

Description : Ionisation potential employed in the industrial electrostatic precipitator is of the order of (A) 30 to 70 kV DC (B) 30 to 70 kV AC (C) 230 V AC (D) 230 V DC

Last Answer : (A) 30 to 70 kV DC

Description : A series combination of resistance 100 ohm and capacitance 50µf is connected in series to a 230 V, 50HZ supply. Calculate (i) Capacitive reactance (ii) Current (iii) Power factor (iv) Power consumed 

Last Answer : For RC series circuit

Description : An AC supply of 230 V is applied to half wave rectifier circuit. A transformer turns ratio is 20 : 1. Find i) Output DC voltage (ii) Peak Inverse Voltage (PIV)

Last Answer : Solution:

Description :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Last Answer :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Description : What size motor overloads to put on a 3 phase motor.i how to go about to calculate this. its a 5 HP Motor208-230 volt12.9amp at 208SF1.25 SFA 16.1. the motor is a outdoor motor replacing and old o?

Last Answer : 5 HP is equal to 3.7 KW. 415 Volts 3 phase 50 hz system takes 6.29 amps. Same 3.7 KW motor with 230 volts, single phase 50 hz takes 18.9 amps. Same 3.7 kw motor with 230 volts three phase ... 0.85 assumed power factor. To arrive at over load, you may 5 to10% over load and set the over load setting.

Description : The primary turns of a 444 V/222 V, 50 Hz single-phase transformer with a core cross-sectional area of 100 cm2, and a maximum flux density of 1.0 T is (A) 100 (B) 200 (C) 222 (D) 400

Last Answer : The primary turns of a 444 V/222 V, 50 Hz single-phase transformer with a core cross-sectional area of 100 cm2, and a maximum flux density of 1.0 T is 200

Description : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ?  (a) 100 VAR (b) 200 VAR (c) 300 VAR (d) 400 VAR

Last Answer : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ? 400 VAR