Why should a mercury cell NOT be shorted?

1 Answer

Answer :

The danger of explosion.

Related questions

Description : Why should a mercury cell NOT be shorted?

Last Answer : The danger of explosion.

Description : When you are using an ohmmeter to test a transistor for leakage, what is indicated by a low, but not shorted, reverse resistance reading?

Last Answer : A leaking transistor

Description : When you zero a synchro with a synchro tester, what is indicated by a jump in the synchro tester's dial when the S1 and S3 leads are momentarily shorted?

Last Answer : The synchro under test is not on electrical zero.

Description : If one branch of a parallel network is shorted, what portion of circuit current flows through the remaining branches?

Last Answer : None.

Description : When testing an SCR with an ohmmeter, the SCR will conduct if what two elements are shorted together?

Last Answer : Gate and anode.

Description : You have just checked a fuse with an ohmmeter and find that the fuse is shorted. What should you

Last Answer : Put it back in the circuit. A good fuse will have zero ohms of resistance.

Description : A lead-acid battery may become hotter than normal during a charge if the _________. A. battery has a shorted cell B. charging voltage is too low C. specific gravity is too high D. battery room door is secured

Last Answer : Answer: A

Description : What precautions should be exercised when using mercury-vapor thyratrons?

Last Answer : . The filament’s voltage should be applied to the tube at least 30 seconds before attempting to operate the tube.

Description : What is the purpose of rotating the gimbal assembly in a gyro using a mercury erection system?

Last Answer : Applies torque at the proper point for correct precession.

Description : Have you ever experienced a situation where a store or restaurant gave you the wrong change (shorted you) and what did you do about it?

Last Answer : answer:If they “decided to stick” with the original, despite my insistence that I gave them $40, I’d demand the manager and have them count the drawer. I have absolutely no patience for shysters, and $10 is not “no big deal” to me.

Description : Has anyone else had their dashboard lights shorted out by motor oil?

Last Answer : No, but…I had a new battery installed a couple years ago that flipped my gas gage needle backwards and while it has been spun around again, several times with a magnet, it still flips back into the dead zone every so often. haha Car stuff…PITA!

Description : Why is the side-side shorted during the short circuit test in the transformer ?

Last Answer : During this test, any side of the transformer can be shorted, but for the following reasons, the side-side is shorted and 1. Lay-range instruments have the advantage of being connected to the high side ... both windings below 3% of the rated output , so it is convenient to measure on the high side.

Description : How do you repair driver side airbag circuit low resistance or shorted Ford F150?

Last Answer : It might be a problem with the "clock spring".

Description : When using the test set-up shown in the illustration, the lighted lamp indicates the winding is ____________. EL-0027 A. grounded B. good C. open D. shorted

Last Answer : Answer: A

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the main winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica

Last Answer : Answer: A

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the run winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : When a megohmmeter is being used on a alternating current machine, the meter pointer will dip toward 'zero' and then gradually rise to the true resistance value if the motor insulation is _____________. A. grounded B. good C. shorted D. dirty

Last Answer : Answer: B

Description : A three-phase, squirrel cage, induction motor will run hot due to a/an ______________. A. improper brush position B. reversed commutating pole C. shorted stator D. high power factor

Last Answer : Answer: C

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : If all three ground-detection lamps continue to burn at equal intensity after the test button is depressed and released, which of the listed conditions is indicated? A. No grounds exist B. All three phases are grounded C. The test switch is faulty D. The current transformers are shorted out

Last Answer : Answer: A

Description : A capacitor is to be tested with a megohmmeter. If the meter is connected to a shorted capacitor, the meter pointer should _____________. A. immediately swing to the maximum resistance value ... and gradually decrease D. swing to zero then gradually increase with slight pointer movements down scale

Last Answer : Answer: B

Description : The leads from a megohmmeter are attached to the leads of an AC motor field coil. A reading of infinity is obtained indicating a/an ____________. A. open field coil B. shorted field coil C. grounded field coil D. shunted field coil

Last Answer : Answer: A

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : A megohmmeter can be used to test for _____________. A. an open field coil B. a shorted field pole C. undercut mica D. reversed polarity

Last Answer : Answer: A

Description : While testing a semi-conductor diode with an ohmmeter, both the forward and reverse readings are almost in the infinity range. This would indicate that the unit is _____________. A. good B. open C. grounded D. shorted

Last Answer : Answer: B

Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage

Last Answer : Answer: C

Description : One diode of a full-wave rectifier has burned out in a shorted condition. Therefore, the output will be ____________. A. zero B. a rectified half-wave C. a rectified full-wave D. equal to the AC input

Last Answer : Answer: D

Description : You have installed a Zener diode in parallel with a load. While measuring the voltage across the Zener diode it is found that it does not change as the current through the load increases. This means that the ... is working as it should B. is shorted C. is open D. does not regulate as it should

Last Answer : Answer: A

Description : Prior to using an analog type ohmmeter, the leads are purposely shorted together. Which of the following actions should be taken if, when adjusting to 'zero' ohms, the indicating needle can not be ... be added to each final reading. D. The test reading should be subtracted from each final reading.

Last Answer : Answer: B

Description : When troubleshooting AC motors, a portable growler can be used for locating ____________. A. open field coils B. grounded field coils C. grounded stator coils D. shorted stator coils

Last Answer : Answer: D

Description : A testing device called a 'growler' is being used to locate a shorted coil in the stator of an AC electrical machine. When the 'feeler' is moved over a slot containing the shorted coil _____________. ... . the meter needle will be deflected to zero D. the meter needle will be deflected to full-scale

Last Answer : Answer: A

Description : On a switchboard, if all three ground detection lamps remain burning at half intensity when the test button is depressed, which of the listed conditions is indicated? A. No grounds exist. B. All three phases are grounded. C. The test switch is grounded. D. The current transformers are shorted.

Last Answer : Answer: A

Description : A capacitor can be tested using a megohmmeter or an ohmmeter. If the meter is connected to a shorted capacitor, the meter pointer should _____________. A. immediately swing to the maximum resistance ... deflect to and remain at zero D. immediately swing to a high reading and then gradually decrease

Last Answer : Answer: C

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : What is the reactance property at the input of a shorted quarter wavelength line? A. A parallel LC circuit B. A pure inductive reactance C. A series LC circuit D. A pure capacitive reactance

Last Answer : A. A parallel LC circuit

Description : Characteristics impedance of a transmission line is the impedance measured at the ___________ when its length is infinite. A. input B. shorted end of the line C. output D. midsection

Last Answer : A. input

Description : When a switch capacity is full, calls coming into that switch are said to be____. (A) open (B) shorted (C) blocked (D) shunted

Last Answer : (C) blocked

Description : In an amplifier the collector voltage equals the full V+ of 28 V instead of the normal 12 V which of the following can be the trouble? A) RL is open B) Cc is open C) RE is open D) CE is shorted.

Last Answer : B) Cc is open

Description : Draw waveform for standing waves on an open and shorted line. Prove that impedance is inverted at every quarter wavelength interval.

Last Answer : Waveform- Explanation When the transmission line is short circuited voltage is zero and current is maximum.The variation is according to the wavelength. When the ... The pattern repeats for every half wavelength. Thus impedance is inverted at every quarter wavelength interval.

Description : A cylindrical rotor synchronous motor is switched on to the supply with its field windings shorted on themselves, the motor will .  A) Not start B) Start but will not run at synchronous speed C) Start as an induction motor and then run as a synchronous motor D) Start and run as a synchronous motor

Last Answer : A cylindrical rotor synchronous motor is switched on to the supply with its field windings shorted on themselves, the motor will Start but will not run at synchronous speed

Last Answer : In a power supply a shorted input capacitor is likely to result in No voltage output.

Description : The cell which is used as standard cell is: a) Dry cell b) Solar cell c) Mercury-Cadmium cell d) Zinc-Carbon cell

Last Answer : Ans: C

Description : When troubleshooting an alkaline storage battery a weak or dead cell is best located by ____________. A. checking the specific gravity of each cell B. visually inspecting each cell's ... testing each cell with a voltmeter D. measuring the electrolyte temperature with an accurate mercury thermometer

Last Answer : Answer: C

Description : When troubleshooting a lead-acid storage battery, a weak or dead cell is best detected by _________________. A. measuring and comparing all cells' specific gravity B. taking an open circuit ... electrolyte levels of each cell D. taking each cell's temperature with a calibrated mercury thermometer

Last Answer : Answer: A

Description : Caustic soda is produced in a mercury cell having anode and cathode made respectively of moving mercury and (A) Moving mercury and graphite (B) Graphite and moving mercury (C) Moving mercury and carbon (D) Moving mercury and crimped steel wire

Last Answer : (B) Graphite and moving mercury