An instrument thAn instrumAn instrument that must be calibrated in place requires  what type of calibration label?

1 Answer

Answer :

SPECIAL CALIBRATION label.

Related questions

Description : What calibration label is used when actual measurement values must be known to use the test equipment?

Last Answer : CALIBRATED—REFER TO REPORT.

Description : When using a multimeter for resistance measurements, it should be calibrated by clipping the loose ends of the leads together and _____________. A. setting the instrument pointer at 'zero' ohms B. ... the plus and minus terminals D. using a special purpose resistance measuring instrument (a bridge)

Last Answer : Answer: A

Description : What equipment uses a calibrated resonant circuit to measure frequency?

Last Answer : Wavemeter.

Description : State necessity of instrument calibration.

Last Answer : Necessity of instrument calibration: - ➢ To ensure reading from an instrument are consistent with other measurements. ➢ To determine the accuracy of the instrument reading. ➢ To ... Calibration Keeps Processes Safe ➢ Calibration Maintains Certification ➢ Reduce Costs from Manufacturing Errors

Description : need of calibration and explain the procedure to calibrate the instrument.

Last Answer : Need of calibration: Every measuring device degrades over time due to normal wear and tear. These changes can be caused by various reasons such as electric or mechanical shock or a hazardous manufacturing ... different magnitude are used to calculate the resistance based on ohm's law.

Description : Explain need of calibration of any instrument.

Last Answer : Calibration is the comparison between measurements: between a standard known value and the unknown value.  There are three main reasons for having instruments calibrated: 1. To ensure readings from an instrument ... . 3. To establish the reliability of the instrument i.e. that it can be trusted.

Description : What are some examples when the word calibrated is used in a lay person's life?

Last Answer : TV screen – to make the picture display correctly. Printer – to make the different colours align. Oven with an oven thermometer – to make sure it’s at the temperature you think it’s at. Laptop battery – so that the display gives an accurate readout of how much powered left. A cars wheel alignment.

Description : What's the process by which the line of sight from a scope and the path of a bullet from a rifle is calibrated?

Last Answer : In mechanics, I studied this. Trajectory or path of the bullet is parabolic. You may read Rifle Bullet Trajectory. Rifle shooting tips Rifle Trajectory Table Parts of a trajectory

Description : How a thermometer is calibrated?

Last Answer : How a thermometer is calibrated?

Description : Can I use eurometer calibrated in RMS to measure HWDC in peak?

Last Answer : No

Description : What calibrated tool was the standard tool for engineers and scientists prior to the invention of the hand-held calculator?

Last Answer : Slide rule

Description : The most effective method of locating a loose commutator bar in a D.C. motor is by _____________. A. visual inspection B. jiggling each by hand C. sounding each bar with a light weight hammer D. checking with a calibrated torque wrench

Last Answer : Answer: C

Description : A capacitor discolored due to excessive heat should be _____________. A. calibrated using a capactance wheatstone bridge B. replaced and the reason for the overheating found C. cooled with a spray ... purpose D. resoldered with care taken to insure that the origional cold solder joint is repaired

Last Answer : Answer: B

Description : Most AC voltmeters are calibrated to indicate __________. A. peak-to-peak voltage B. root-mean-square voltage C. average voltage D. peak voltage only

Last Answer : Answer: B

Description : AC voltmeters are generally calibrated to read the ________. A. instantaneous voltage B. average voltage C. RMS voltage D. peak voltage

Last Answer : Answer: C

Description : When troubleshooting a lead-acid storage battery, a weak or dead cell is best detected by _________________. A. measuring and comparing all cells' specific gravity B. taking an open circuit ... electrolyte levels of each cell D. taking each cell's temperature with a calibrated mercury thermometer

Last Answer : Answer: A

Description : A capacitor discolored due to excessive heat should be _____________. A. calibrated B. replaced C. cooled D. soldered

Last Answer : Answer: B

Description : Explain How Can A D.p. Transmitter Be Calibrated?

Last Answer : D.P. transmitter can be calibrated using following steps: 1. Adjust zero of Xmtrs. 2. Perform static pressure test: Give equal pressure on both sides of transmitter. Zero should not shift either ... Apply required pressure to the high pressure side and adjust the span. Adjust zero gain if necessary.

Description : How Can A D.p. Transmitter Be Calibrated?

Last Answer : D.P. transmitter can be calibrated using following steps: 1. Adjust zero of Transmitter. 2. Perform static pressure test: Give equal pressure on both sides of transmitter. Zero should not ... Apply required pressure to the high pressure side and adjust the span. Adjust zero gain if necessary.

Description : For amplitude measurements, ___ scale is calibrated in either volts per centimeter (V/cm), or millivolts per centimeter (mV/cm)

Last Answer : vertical

Description : Optical cable testers are used for ∙ a. Checking refractive index ∙ b. Light power out of a fiber ∙ c. Non-calibrated light into a fiber

Last Answer : b. Light power out of a fiber

Description : Optical cable testers are used for ∙ a. Checking refractive index ∙ b. Light power out of a fiber ∙ c. Non-calibrated light into a fiber

Last Answer : ∙ b. Light power out of a fiber

Description : For ultrasonic testing, which of the following statements is true? a) It is easy to identify all defects b) The equipment shall be calibrated before use c) The equipment cannot be automated d) Sound waves will not travel through copper

Last Answer : b) The equipment shall be calibrated before use

Description : How can a periodontal pocket be recognised:** A. X-Ray B. Periodontal probe / Calibrated probe C. Periodontal marker D. Bitewing radiograph E. Sharp explorer F. Study cast

Last Answer : B. Periodontal probe / Calibrated probe

Description : If digital DRT is calibrated for 300 mm longitudinal wave using 00 double crystal probe then 60kg rail ---------peak will appear at (i) 5.2 (ii) 5.7* (iii) 7.8 (iv) 8.6

Last Answer : ii) 5.7*

Description : What type of data transfer requires the most time?

Last Answer : Serial.

Description : What type of ranging circuit is most often used with a radar that requires extremely accurate range data?

Last Answer : Range gate or range step.

Description : What type of bias requires constant current flow through the cathode

Last Answer : Cathode biasing.

Description : What type of switch should be used to control a circuit that requires a temporary actuation signal?

Last Answer : A momentary switch.

Description : What type of prime mover requires a specially designed high-speed alternator?

Last Answer : Steam turbine.

Description : Explain calibration of capacitive type level measurement.

Last Answer : ➢ Calibration of capacitance type level transmitter 1. Remove the level transmitter from the system(tank). 2. check whether transmitter shows zero reading by connecting with multimeter otherwise release the ... rotate the span screw to 20ma. 3. Repeat these steps and check all readings

Description : Explain the calibration of series type ohmmeter.

Last Answer : Series Ohmmeter If the resistor's value is unknown and has to be measured by placing it in series with the ohmmeter, then that ohmmeter is called series ohmmeter. The circuit diagram of ... hand of the scale respectively. Series ohmmeter is useful for measuring high values of resistances.

Description : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is

Last Answer : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is 2.5 milliOhm

Description : Trade-offs between competing effects are necessary for high speed response. Which competing effect (fast transit time, low capacitance, or high quantum efficiency) requires a thin active area?

Last Answer : Fast transit time.

Description : If the load in question 50 requires a voltage of +90 V, what should be the value of the bleeder resistor?

Last Answer : 2 kΩ

Description : Pulse-code modulation requires the use of approximations of value that are obtained by what process?

Last Answer : Quantization.

Description : What characteristic of sound enables a person to distinguish one musical instrument from another, if they are all playing the same note?

Last Answer : Quality.

Description : Sound waves transmitted from a source are sometimes weak when they reach the detector. What instrument is needed to boost the weak signal?

Last Answer : An amplifier.

Description : How should a delicate instrument be protected from a magnetic field?

Last Answer : By shielding or surrounding the instrument with a soft iron case, called a magnetic shield or screen.

Description : What instrument is used for measuring the insulation resistance of cables?

Last Answer : Megohmmeter (megger).

Description : what- A sign in the grocery store states:All items in aisle 1 r organic.You choose a banana from aisle 1 and you conclude that it must b organic. However the label on the banana says that its conventionally grown (not organic).Whats the error in logic?

Last Answer : The conditional statement was false.

Description : For whom is it a necessity?

Last Answer : http://www.pohodna.cz/?qa=11885/kdo-musi-mit-energeticky-stitek http://www.primabuilding.cz/energeticky-stitek/

Last Answer : Household appliances manufactured after 2001. Energy labels for buildings were abolished on 1,1,2013 and are being replaced by energy performance certificates for buildings

Description : What sae standards must be referred to on label of approved hfc-134a refrigerant recycling machines?

Last Answer : SAE J2210 or SAE J2788

Description : Could the calibration of my speedometer be wrong?

Last Answer : Yes. There are a whole number of reasons a speedo could be reporting the wrong speed. The most common cause of errors is when the tyres (or wheels) have been changed to ones with different diameters to ... so in the worst case scenario it could be out by 20%. Probably worth getting it checked out.

Description : What is Best Buy "Calibration."?

Last Answer : answer:It’s not worth it. I talked with a Best Buy salesrep before I bought my TV and even he admitted it wasn’t worth it. Basically, they’ll look at where your windows are and where you couch is, then ‘calibrate’ the video settings on your TV to ‘maximize’ the image.

Description : What Monitor Calibration Solution do you recommend?

Last Answer : Get a spyder—the cheapest will do fine for what you’re doing. Anyone who doesn’t have a calibrated monitor won’t care that your colors are off, anyone who does, will be happy with it. http://www.bhphotovideo.com/c/product/649202-REG/Datacolor_DC_S3X100_Spyder3Express_Color_Calibration_System.html

Description : Macbook colour calibration....colour on my screen doesn't match my pantone swatch?

Last Answer : You need one of these: http://www.bhphotovideo.com/c/product/649202-REG/Datacolor_S3E100_Spyder3Express_Color_Calibration_System.html (If you need to match a pantone swatch reliably, you can’t just eyeball the calibration)

Description : I just picked up a Dell E198WFP display to use with my MacBook Pro. Any colour calibration tips?

Last Answer : I can’t find it, but if you search lifehacker you’ll find the article that they had maybe a month ago about color calibration. They had some great program (windows and mac compatible) to calibrate all the screens perfectly. Search around and hopefully you’ll find it!