Economizer is provided to utilize the flue gas heat for ___
a) preheating the boiler feed water
b) preheating the stock
c) preheating the combustion air
d) preheating fuel

1 Answer

Answer :

preheating the boiler feed water

Related questions

Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Recovery of heat from dryer exhaust air is a typical application of: a) Waste heat recovery boiler b) Heat pump c) Heat wheel d) Economizer

Last Answer : Heat wheel

Description : Recovery of waste heat from hot fluid to fluid is called: a) thermo compressor b) waste heat recovery boiler c) heat Pump d) economizer

Last Answer : heat Pump

Description : Fuel economy in furnaces can be achieved by (A) Using oxygen enriched combustion air (B) Preheating the combustion air (C) Reducing the heat loss through furnace openings & doors (D) All (A), (B) and (C

Last Answer : (D) All (A), (B) and (C

Description : In case of pulverised coal fired steam boiler, the secondary air serves the main purpose of (A) Transportation of coal (B) Drying of coal (C) Combustion of coal by supplying it around the burner (D) Preheating the primary air

Last Answer : (C) Combustion of coal by supplying it around the burner

Description : In case of pulverised coal fired steam boiler, the secondary air serves the main purpose of (A) Transportation of coal (B) Drying of coal (C) Combustion of coal by supplying it around the burner (D) Preheating the primary air

Last Answer : (C) Combustion of coal by supplying it around the burner

Description : Which of the following accounts for maximum energy loss in a boiler? (A) Flue gases (B) Ash content in the fuel (C) Incomplete combustion (D) Unburnt carbon in flue gases

Last Answer : (A) Flue gases

Description : Preheating of a gaseous fuel results in increased (A) Flame length (B) Flame temperature (C) Quantity of flue gas

Last Answer : (B) Flame temperature

Description : Too much of excess air in combustion results in high (A) Fuel consumption for the same heat load (B) Stack gas temperature (C) Percentage of oxygen in flue gases (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The main drawback of supplying more excess air in the combustion of fuel is the (A) Excessive power requirement of air blower (B) Enhanced sensible heat loss in the flue gas (C) Intermittent and uncontrolled combustion of the fuel (D) High exit flue gas temperature from the furnace

Last Answer : (B) Enhanced sensible heat loss in the flue gas

Description : Through what is feed water from hot-well is passed through, before entering steam and water drum in Lamont boiler? a. Evaporator tubes b. Economizer c. Distributor header d. Circulating pump

Last Answer : b. Economizer

Description : Higher furnace temperature cannot be achieved by use of a lean fuel gas in the furnace by (A) Increasing the draft in the furnace (B) Preheating the fuel gas (C) Oxygen enrichment of combustion air (D) Preheating the combustion air

Last Answer : (A) Increasing the draft in the furnace

Description : Temperature of a furnace fired with low calorific value fuel gas (i.e. lean gas) can be increased by (A) Preheating the combustion air (B) Oxygen enrichment of combustion air (C) Preheating the fuel gas (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : In general, the limit of inflammability/explosion limit of fuel gases is widened by the (A) Increase in gas pressure (B) Increase in temperature (i.e. preheating) (C) Use of pure oxygen for combustion instead of air (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : measures oxygen and temperature of the flue gas. a) Fuel efficiency monitor. b) Combustion analyzer. c) Contact thermometer. d) Infrared thermometer.

Last Answer : Combustion analyzer

Description : The economiser is used in boilers to........ A]Increase thermal efficiency of boiler B]Economise on fuel C]Extract heat from the exhaust the gases D]Increase flue gas temperature

Last Answer : A]Increase thermal efficiency of boiler

Description : Scale formation in boiler is controlled by (A) Preheating of feed water (B) Reduction in hardness, silica & alumina in feed water (C) Keeping the pH value of feed water just below 7 (D) Eliminating H2S in feed water

Last Answer : (B) Reduction in hardness, silica & alumina in feed water

Description : Soluble silica present in boiler feed water can be removed by (A) Coagulation (B) Filtration (C) Anion exchanger (D) Preheating it

Last Answer : (C) Anion exchanger

Description : Preheating of combustion air is done to (A) Increase the adiabatic flame temperature (B) Increase the calorific value of the fuel (C) Complete the combustion of fuel (D) Reduce its requirement for effecting the complete combustion

Last Answer : (A) Increase the adiabatic flame temperature

Description : Preheating of __________ the flame temperature. (A) The gaseous fuel before combustion decreases (B) Combustion air decreases (C) Either the fuel or the air or both, increases (D) Either the fuel or the air does not affect

Last Answer : (C) Either the fuel or the air or both, increases

Description : Higher fuel combustion efficiency cannot be achieved by (A) Preheating of fuel gases & combustion air (B) Reducing sulphur content in the fuel (C) Adopting proper fuel firing technique & fuel preparation (D) Supplying correct amount of combustion air

Last Answer : (B) Reducing sulphur content in the fuel

Description : Flue gases coming out from furnace is first going through a) Turbine b) Economizer c) Air pre-heater d) Chimney

Last Answer : Ans: Economizer

Description : In practical operation of any furnace, zero oxygen percentage or theoretical CO2 percentage in flue gas is rarely achieved, because of (A) Use of non-preheated combustion air (B) Use of pulverised solid ... of fuel & air and infiltration of air (D) Use of excessive positive draft in the furnace

Last Answer : (C) Imperfect mixing of fuel & air and infiltration of air

Description : Combustion of fuel in a furnace with oxygen enriched air results in higher (A) Flue gas volume (B) Flame temperature (C) Fuel consumption (D) Stack loss

Last Answer : (B) Flame temperature

Description : Pick out the wrong statement. (A) High concentration of oxygen in flue gas means high stack loss (B) Gaseous fuels require the least % excess air for complete combustion (C) The ratio of fixed carbon to ... coal is called its 'fuel ratio' (D) Calorific value of natural gas is more than that of LPG

Last Answer : (D) Calorific value of natural gas is more than that of LPG

Description : Higher efficiency in the combustion of solid fuel cannot be achieved by (A) Proper fuel preparation (B) Keeping the flue gas exhaust temperature very high (C) Adopting efficient-fuel firing technique & equipment (D) Supplying correct quantity of combustion air

Last Answer : (B) Keeping the flue gas exhaust temperature very high

Description : A carbonaceous fuel (containing no H2 or hydrocarbons) is burnt and the resulting flue gas contains 21% CO2 . It means that (A) 21% excess air has been used for combustion (B) 21% excess oxygen has ... (C) Complete combustion of fuel has taken place (D) No excess air has been used for combustion

Last Answer : (C) Complete combustion of fuel has taken place

Description : Volumetric composition of flue gas analysed with the Orsat apparatus is : CO2 = 12%, O2 = 8%, CO = nil, N2 = 80%. This flue gas composition indicates that (A) Pure oxygen has been used for combustion ... very high (C) Excess air has been used for combustion (D) Hydrogen is not present in the fuel

Last Answer : (C) Excess air has been used for combustion

Description : Oxygen trim control strategy __ a. continuously measures the oxygen content in the flue gas b. adjusts the combustion air flow c. Continually tuning the air-fuel mixture. d. All of above

Last Answer : d. All of above

Description : In which of the waste heat recovery equipment, the flow of flue gas and air is alternately reversed after a fixed interval of time? (A) Recuperator (B) Regenerator (C) Waste heat boiler (D) None of these

Last Answer : (B) Regenerator

Description : Nellore to medium temperature waste heat recovery system the most suitable device is ------ a) Economizer b) Heat wheels c) Air preheater d) Recuperate d) Carbonate

Last Answer : Heat wheels

Description : What is the function of boiler? • To burn the fuel in a confined closed system With the supply of air • To generate steam in varying pressure • To generate steam at constant pressure • To produce flue gases by burning fuel at a given pressure

Last Answer : • To generate steam at constant pressure

Description : White flue gas (resembling steam) coming out of the chimney of a thermal power plant indicates that the fuel used in the boiler furnace is (A) Tar (B) Coke oven gas (C) Pitch (D) Pulverised coke

Last Answer : (B) Coke oven gas

Description : Oxygen enrichment of combustion air does not result in increase of the (A) Flame temperature (B) Oxygen in the flue gas (C) Stack loss (D) Heat transfer rate in the furnace

Last Answer : (B) Oxygen in the flue gas

Description : Presence of nitrogen in combustion air does not reduce the (A) Amount of heat liberated (B) Flame temperature (C) Flue gas temperature (D) Any of the above

Last Answer : (A) Amount of heat liberated

Description : Acid dew point temperature (ADT) of a flue gas produced by the combustion of a fuel containing 1% sulphur may be about __________ °C. (A) 80 (B) 130 (C) 180 (D) 250

Last Answer : (B) 130

Description : If oxygen content in the flue gas rises too high, fuel is being wasted by (A) Incomplete combustion (B) Dry gas/stack gas loss (C) Moisture loss (D) None of these

Last Answer : (B) Dry gas/stack gas loss

Description : During combustion of a gaseous fuel, the presence of a non-luminous flame is an indication of the (A) Incomplete combustion (B) Complete combustion (C) High oxygen in flue gas (D) None of these

Last Answer : (B) Complete combustion

Description : Efficiency of the combustion of a fuel is judged by the __________ the flue gas. (A) % of CO2 in (B) % of O2 in (C) Temperature of (D) Colour of

Last Answer : (B) % of O2 in

Description : Flue gas obtained on complete combustion of pure acetylene (a hydrocarbon fuel) will contain (A) CO (B) CO2 (C) H2O (D) Both (B) & (C)

Last Answer : (D) Both (B) & (C)

Description : Incomplete combustion of a fuel is characterised by the high __________ in the flue gas. (A) Smoke (B) Temperature (C) Oxygen (D) Carbon monoxide

Last Answer : (D) Carbon monoxide

Description : Which among the following has the highest flue gas loss on combustion due to Hydrogen in the fuel? a) natural gas b) furnace oil c) coal d) light diesel oil

Last Answer : a) natural gas

Description : Which instrument is used to monitor O2, CO in flue gas? (EA) a) Combustion analyser b) Power analyser c) Pyrometer d) Fyrite

Last Answer : Combustion analyser

Description : instrument is used to monitor O2, CO in flue gas (EA) a) Combustion analyzer b) Power analyzer c) Pyrometer d) Fyrite

Last Answer : Combustion analyzer

Description : Which instrument is used to monitor O2, CO in flue gas? c)Combustion analyzer c) Pyrometer d)Power analyzer d) Fyrite

Last Answer : Combustion analyzer

Description : 115. Which instrument is used to monitor O2, CO in flue gas? a) Combustion analyzer c) Pyrometer b) Power analyzer d) Fyrite

Last Answer : Combustion analyzer

Description : A __________ is a type of heat exchange system where water is heated to its' boiling point via combustion of a fuel blown through a tube submerged in water. a. Condensate loop b. Hyperbolic cooling tower c. Steam boiler d. All of above

Last Answer : c. Steam boiler

Description : In a boiler enthalpy of water supplied was 2000 kJ/kg. Enthalpy being added by fuel combustion is 3200 kJ/kg. Using first law of thermodynamics, find amount of heat supplied if steam generation rate is 10 tons per hour.

Last Answer : Heat supplied Q = m (h2-h1) …….(Steady flow energy equation for boiler) ; h2=3200 KJ/kg h1=2000 KJ/kg m = 10 Tons /hour = (10 x 1000)/3600 kg/sec = 2.77 Kg/sec Q = 2.77(3200-2000) = 3324 KJ/sec heat supplied for 10 Tons/hr steam generation

Description : Which of the following is not increased by using preheated combustion air in place of ordinary air at room temperature? (A) Calorific value of the fuel (B) Flame temperature achieved (C) Speed of combustion of fuel (D) Heat transfer rate to the stock in the furnace

Last Answer : (A) Calorific value of the fuel

Description : The biggest loss in the boiler is a) Moisture in fuel b) Dry flue gases c) Steam formation d) Unburnt carbon

Last Answer : b) Dry flue gases