Description : Pick out the wrong statement. (A) High concentration of oxygen in flue gas means high stack loss (B) Gaseous fuels require the least % excess air for complete combustion (C) The ratio of fixed carbon to ... coal is called its 'fuel ratio' (D) Calorific value of natural gas is more than that of LPG
Last Answer : (D) Calorific value of natural gas is more than that of LPG
Description : A carbonaceous fuel (containing no H2 or hydrocarbons) is burnt and the resulting flue gas contains 21% CO2 . It means that (A) 21% excess air has been used for combustion (B) 21% excess oxygen has ... (C) Complete combustion of fuel has taken place (D) No excess air has been used for combustion
Last Answer : (C) Complete combustion of fuel has taken place
Description : Too much of excess air in combustion results in high (A) Fuel consumption for the same heat load (B) Stack gas temperature (C) Percentage of oxygen in flue gases (D) All (A), (B) and (C)
Last Answer : (D) All (A), (B) and (C)
Description : Volumetric composition of flue gas analysed with the Orsat apparatus is : CO2 = 12%, O2 = 8%, CO = nil, N2 = 80%. This flue gas composition indicates that (A) Pure oxygen has been used for combustion ... very high (C) Excess air has been used for combustion (D) Hydrogen is not present in the fuel
Last Answer : (C) Excess air has been used for combustion
Description : Pure carbon is completely burnt in oxygen. The flue gas analysis is 70%CO2 , 20%CO and 10%O2 . The percent excess oxygen used is (A) 20 (B) 12.5 (C) 0 (D) 10
Last Answer : (C) 0
Description : Oxygen trim control strategy __ a. continuously measures the oxygen content in the flue gas b. adjusts the combustion air flow c. Continually tuning the air-fuel mixture. d. All of above
Last Answer : d. All of above
Description : Ostwald charts are meant for (A) Computing the excess/deficiency of combustion air (B) Calculation of flue gas temperature (C) Computation of flue gas analysis (D) None of these
Last Answer : (A) Computing the excess/deficiency of combustion air
Description : The main drawback of supplying more excess air in the combustion of fuel is the (A) Excessive power requirement of air blower (B) Enhanced sensible heat loss in the flue gas (C) Intermittent and uncontrolled combustion of the fuel (D) High exit flue gas temperature from the furnace
Last Answer : (B) Enhanced sensible heat loss in the flue gas
Description : If oxygen content in the flue gas rises too high, fuel is being wasted by (A) Incomplete combustion (B) Dry gas/stack gas loss (C) Moisture loss (D) None of these
Last Answer : (B) Dry gas/stack gas loss
Description : Incomplete combustion of a fuel is characterised by the high __________ in the flue gas. (A) Smoke (B) Temperature (C) Oxygen (D) Carbon monoxide
Last Answer : (D) Carbon monoxide
Description : A sample of natural gas containing 80% methane (CH4 ) and rest nitrogen (N2 ) is burnt with 20% excess air. With 80% of the combustibles producing CO2 and the remainder going to CO, the Orsat analysis in volume percent is (A) CO2 : 6 ... 96, N2 :72.06 (D) CO2 : 7.60, CO : 1.90, O2 : 4.75, N2 : 85.74
Last Answer : (B) CO2 : 7.42, CO : 1.86, O2 : 4.64, N2 :86.02
Description : Oxygen enrichment of combustion air does not result in increase of the (A) Flame temperature (B) Oxygen in the flue gas (C) Stack loss (D) Heat transfer rate in the furnace
Last Answer : (B) Oxygen in the flue gas
Description : Out of the following fuels used in a furnace exhausting flue gas at a temperature of 600°C, the percentage stack loss will be maximum in case ofcomplete combustion of (A) Furnace oil with air (B) Furnace oil with oxygen (C) Blast furnace gas with air (D) Blast furnace gas with oxygen
Last Answer : (C) Blast furnace gas with air
Description : In practical operation of any furnace, zero oxygen percentage or theoretical CO2 percentage in flue gas is rarely achieved, because of (A) Use of non-preheated combustion air (B) Use of pulverised solid ... of fuel & air and infiltration of air (D) Use of excessive positive draft in the furnace
Last Answer : (C) Imperfect mixing of fuel & air and infiltration of air
Description : Combustion of fuel in a furnace with oxygen enriched air results in higher (A) Flue gas volume (B) Flame temperature (C) Fuel consumption (D) Stack loss
Last Answer : (B) Flame temperature
Description : A liquid/gaseous fuel containing hydrocarbons and high amount of sulphur is burnt with 40% excess air. The flue gas still contains large amount of carbon monoxide. This may be due to the (A) Presence of large ... fuel (C) High sulphur content in the fuel (D) Lack of thorough mixing of fuel with air
Last Answer : (D) Lack of thorough mixing of fuel with air
Description : Oxygen percentage in the flue gas coming out of a gaseous fuel fired furnace should be ideally about __________ percent. (A) < 2 (B) < 5 (C) < 8 (D) < 10
Last Answer : (A) < 2
Description : The excess air required for the combustion of pulverised coal is of the order of about __________ percent. (A) 5 (B) 15 (C) 30 (D) 45
Last Answer : (B) 15
Description : Incomplete combustion of fuel in the furnace is judged by high __________ of the flue gases. (A) CO content (B) Dew point (C) CO2 content (D) O2 content
Last Answer : (A) CO content
Description : High sulphur content in a fuel __________ of the flue gases. (A) Decreases the dew point (B) Increases the dew point (C) Reduces the combustion efficiency by limiting the permissible temperature reduction (D) Both (B) and (C)
Last Answer : (D) Both (B) and (C)
Description : Alcohol content in freshly prepared natural and fortified wine may be respectively around __________ percent. (A) 7-14 and 14-30 (B) 7-14 and 40-50 (C) 14 - 30 and 40-50 (D) 10 - 20 and 40 - 50
Last Answer : (A) 7-14 and 14-30
Description : During combustion of a gaseous fuel, the presence of a non-luminous flame is an indication of the (A) Incomplete combustion (B) Complete combustion (C) High oxygen in flue gas (D) None of these
Last Answer : (B) Complete combustion
Description : measures oxygen and temperature of the flue gas. a) Fuel efficiency monitor. b) Combustion analyzer. c) Contact thermometer. d) Infrared thermometer.
Last Answer : Combustion analyzer
Description : Acid dew point temperature (ADT) of a flue gas produced by the combustion of a fuel containing 1% sulphur may be about __________ °C. (A) 80 (B) 130 (C) 180 (D) 250
Last Answer : (B) 130
Description : Efficiency of the combustion of a fuel is judged by the __________ the flue gas. (A) % of CO2 in (B) % of O2 in (C) Temperature of (D) Colour of
Last Answer : (B) % of O2 in
Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)
Description : Higher efficiency in the combustion of solid fuel cannot be achieved by (A) Proper fuel preparation (B) Keeping the flue gas exhaust temperature very high (C) Adopting efficient-fuel firing technique & equipment (D) Supplying correct quantity of combustion air
Last Answer : (B) Keeping the flue gas exhaust temperature very high
Description : Presence of nitrogen in combustion air does not reduce the (A) Amount of heat liberated (B) Flame temperature (C) Flue gas temperature (D) Any of the above
Last Answer : (A) Amount of heat liberated
Description : Which of the following accounts for maximum energy loss in a boiler? (A) Flue gases (B) Ash content in the fuel (C) Incomplete combustion (D) Unburnt carbon in flue gases
Last Answer : (A) Flue gases
Description : In order to maintain an oxidising atmosphere in a furnace, it should have (A) More of excess air (B) Less of excess air (C) More of CO in flue gas (D) More of CO2 in flue gas
Last Answer : (A) More of excess air
Description : In order to maintain a reducing atmosphere in a furnace, it should have (A) No O2 in flue gas (B) CO in flue gas (C) High excess air (D) None of these
Last Answer : (B) CO in flue gas
Description : Amount of coal lost in ash particle, which is carried through the boiler system, depends upon the (A) Physical nature, ash content and fineness of the coal (B) Amount of excess air supplied and load on the boiler (C) Type of burner and combustion chamber (D) All (A), (B) and (C)
Description : The optimum percentage of excess air for combustion depends upon the__________ of the fuel. (A) Type (solid, liquid or gaseous) (B) Calorific value (C) Sulphur content (D) Ignition temperature
Last Answer : (A) Type (solid, liquid or gaseous)
Description : Furnace oil consumption in a furnace for a given duty employing preheated combination air (at 300°) may be reduced by about __________ percent as compared to the use of atmospheric combustion air. (A) 5 (B) 10 (C) 20 (D) 35
Last Answer : (C) 20
Description : Stack heat losses can be minimised by (A) Controlling the excess air (B) Oxygen enrichment of combustion air (C) Using low c.v. fuels (D) Maintaining proper draft in the furnace
Last Answer : (A) Controlling the excess air
Description : Economizer is provided to utilize the flue gas heat for ___ a) preheating the boiler feed water b) preheating the stock c) preheating the combustion air d) preheating fuel
Last Answer : preheating the boiler feed water
Description : Iron content in Indian iron ore is about __________ percent. (A) 80-85 (B) 60-65 (C) 40-45 (D) 20-25
Last Answer : (B) 60-65
Description : Combustion of furnace oil in a furnace (soaking pit) with preheated combustion air at 400°C results in saving of about __________ percentfurnace oil as compared to its combustion with atmospheric air, if the flue gas outlet temperature from the soaking pit is 1200°C. (A) 5 (B) 60 (C) 20 (D) 40
Description : 150. Nitrogen content in ammonium sulphate (a fertiliser) is around __________ percent. (A) 5 (B) 20 (C) 50 (D) 65
Last Answer : (B) 20
Description : Orsat apparatus is meant for (A) Gravimetric analysis of flue gas (B) Finding out combustion efficiency (C) Direct determination of nitrogen in flue gas by absorbing it in ammoniacal cuprous chloride (D) None of these
Last Answer : (D) None of these
Description : When incomplete combustion loss is high, the flue gas analysis shows large amount of (A) CO2 (B) CO (C) O2 (D) C
Last Answer : (B) CO
Description : Flue gas obtained on complete combustion of pure acetylene (a hydrocarbon fuel) will contain (A) CO (B) CO2 (C) H2O (D) Both (B) & (C)
Last Answer : (D) Both (B) & (C)
Description : Advantages of fluidised bed combustion are (A) Reduced NOx formation in flue gas (B) Lower furnace operating temperature (C) High heat transfer rate (D) All (A), (B) & (C)
Last Answer : (D) All (A), (B) & (C)
Description : Pick out the wrong statement. (A) A slight haze at the top of chimney indicates good combustion in the furnace (B) A bag filter incurs very small pressure drop and is very efficient for ... dust collection equipment for removal of submicronic dust particles present in flue gas (D) None of these
Last Answer : (B) A bag filter incurs very small pressure drop and is very efficient for removal of submicronic dust particles from flue gases at very high temperature
Description : It is easy to detect and monitor excess air a. As oxygen not used for combustion is heated and discharged with the exhaust gases. b. Oxygen is discharged without heating c. Both a. & b. d. None of above
Last Answer : a. As oxygen not used for combustion is heated and discharged with the exhaust gases.
Description : Thermal efficiency of a limestone calcination rotary kiln may be around __________ percent. (A) 20 (B) 40 (C) 65 (D) 80
Last Answer : (B) 40
Description : . Thermal efficiency of an internal combustion engine is around __________ percent. (A) 8 (B) 35 (C) 65 (D) 80
Last Answer : Option B
Description : Thermal efficiency of an internal combustion engine is around __________ percent. (A) 8 (B) 35 (C) 65
Description : As the C/H ratio of the fuel increases, the amount of CO2 formed on combustion __________ for the same percentage of excess air. (A) Decreases (B) Increases (C) Remain same (D) May increase or decrease depending on the type of fuel
Last Answer : (B) Increases
Description : Black smoke coming out of the chimney of a furnace is an indication of the use of __________ in the furnace. (A) Low amount of excess combustion air (B) Large quantity of excess combustion air (C) Hydrocarbon fuel (D) Pulverised coal as fuel
Last Answer : (A) Low amount of excess combustion air