The minimum clear cover for R.C.C. columns shall be
(A) Greater of 40 mm or diameter
(B) Smaller of 40 mm or diameter
(C) Greater of 25 mm or diameter
(D) Smaller of 25 mm or diameter

1 Answer

Answer :

Answer: Option C

Related questions

Description : For a longitudinal reinforcing bar in a column, the minimum cover shall neither be less than the diameter of bar nor less than (A) 15 mm (B) 25 mm (C) 30 mm (D) 40 mm

Last Answer : Answer: Option D

Description : Minimum clear cover (in mm) to the main steel bars in slab, beam, column and footing respectively, are (a) 10, 15, 20 and 25 (b) 15, 25, 40 and 75 (c ) 20, 25, 30 and 40 (d) 20, 35, 40 and 75

Last Answer : (b) 15, 25, 40 and 75

Description : The diameter of main bars in R.C.C. columns, shall not be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm

Last Answer : Answer: Option D

Description : Minimum cover to longitudinal steel in a column should be (if the diameter of bar, Ø> 12mm) [ A ] 25 mm [ B ] 30 mm [ C ] 40 mm [ D ] 50 mm

Last Answer : [ C ] 40 mm

Description : The Minimum pitch of the helical reinforcement in circular columns should be [ A ] 25 mm [ B ] 40 mm [ C ] 50 mm [ D ] 60 mm

Last Answer : [ A ] 25 mm

Description : The difference in the reservoir level and the lowest point of the water mains is 180 m. The  expected pressure due to water hammer is 7.5 kg/cm2  in a pressure conduit of diameter 1 m.  Assuming the efficiency of the ... , is  (A) 10 mm  (B) 15 mm  (C) 20 mm  (D) 25 mm 

Last Answer : (C) 20 mm

Description : The minimum thickness of the cover at the end of a reinforcing bar should not be less than twice the diameter of the bar subject to a minimum of (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm

Last Answer : Answer: Option D

Description : The minimum cover in a slab should neither be less than the diameter of bar nor less than (A) 10 mm (B) 15 mm (C) 25 mm (D) 13 mm

Last Answer : Answer: Option B

Description : The Pitch of helixes in circular columns shall not exceed [ A ] 25 mm [ B ] 50 mm [ C ] 60 mm [ D ] 75 mm

Last Answer : [ D ] 75 mm

Description : Select the incorrect statement from the following [ A ] Reinforcing bars in a column should not be less than 12 mm in diameter [ B ] The number of longitudinal bars in a circular column should not ... The minimum percentage of longitudinal steel in columns should be 0.8% [ D ] None of the above

Last Answer : [ B ] The number of longitudinal bars in a circular column should not exceed four

Description : A spring of mean radius 40 mm contains 8 action coils of steel (N = 80000 N/mm2 ), 4 mm in  diameter. The clearance between the coils being 1 mm when unloaded, the minimum compressive  load to remove the clearance, is  (A) 25 N  (B) 30 N  (C) 35 N  (D) 40 N 

Last Answer : (C) 35 N 

Description : For Unbraced column, the ratio of the clear height of the column to the minimum dimension of the column shall not exceed [ A ] 30 [ B ] 40 [ C ] 50 [ D ] 60

Last Answer : [ A ] 30

Description : The Minimum bar spacing should not be less than [ A ] Diameter of the largest bar [ B ] Maximum size of aggregate [ C ] Greater of diameter of the largest bar and maximum size of aggregate [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm

Last Answer : [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm

Description : The minimum cover to the ties or spirals should not be less than (A) 15 mm (B) 20 mm (C) 25 mm (D) 50 mm

Last Answer : Answer: Option C

Description : Minimum cover for fire resistance for a given simply supported beam, when the fire rating is 1 hour--------- [ A ] 15 mm [ B ] 20 mm [ C ] 25 mm [ D ] 30 mm

Last Answer : [ B ] 20 mm

Description : Minimum cover for fire resistance for a given simply supported beam, when the fire rating is 1 hour--------- [ A ] 15 mm [ B ] 20 mm [ C ] 25 mm [ D ] 30 mm

Last Answer : [ B ] 20 mm

Description : An R.C.C. column of 30 cm diameter is reinforced with 6 bars 12 mm placed symmetrically along the circumference. If it carries a load of 40, 000 kg axially, the stress is (A) 49.9 kg/cm2 (B) 100 kg/cm2 (C) 250 kg/cm2 (D) 175 kg/cm

Last Answer : Answer: Option A

Description : The diameter of transverse reinforcement of columns should be equal to one-fourth of the diameter of the main steel rods but not less than (A) 4 mm (B) 5 mm (C) 6 mm (D) 7 mm

Last Answer : Answer: Option D

Description : When the center of a blind flange is raised, how much smaller in diameter shall the raised portion be in relation to the ID of the fitting? a) 1/2". b) 3/4". c) 1" d) 1.25"

Last Answer : c) 1"

Description : The clear cover in a simply supported slab should not be less than the diameter of the reinforcing bar (a) Correct (b) Incorrect’ (c) Not known (d) None of these

Last Answer : (a) Correct

Description : The concrete slump recommended for columns, is (A) 25 to 50 mm (B) 25 to 75 mm (C) 75 to 125 mm (D) 50 to 100 mm

Last Answer : Answer: Option C

Description : Pick up the correct statement from the following: (A) Lateral reinforcement in R.C.C. columns is provided to prevent the longitudinal reinforcement from buckling (B) Lateral reinforcement prevents ... Lateral reinforcement stops breaking away of concrete cover, due to buckling (D) All the above

Last Answer : Answer: Option D

Description : For a ribbed slab (A) Clear spacing between ribs shall not be greater than 4.5 cm (B) Width of the rib shall not be less than 7.5 cm (C) Overall depth of the slab shall not exceed four times the breadth of the rib (D) All the above

Last Answer : Answer: Option D

Description : The minimum vertical clearance above R.L. to bottom of ROB near the yard shall be a) 6525 mm* b) 5870 mm c) 2360 mm d) 6250 mm

Last Answer : a) 6525 mm*

Description : For high level flush the nominal dia of flush pipe shall be (a) 32 mm* (b) 40 mm (c) 25 mm (d) None of these

Last Answer : a) 32 mm*

Description : The Maximum spacing of Main reinforcement „m‟ slabs shall be [ A ] Less than three times of the effective depth [ B ] Less than 300mm [ C ] Smaller of (a) and (b) [ D ] Greater of (a) and (b)

Last Answer : [ C ] Smaller of (a) and (b)

Description : If the diameter of the main reinforcement in a slab is 16 mm, the concrete cover to main bars is (A) 10 mm (B) 12 mm (C) 14 mm (D) 16 mm

Last Answer : Answer: Option D

Description : The maximum of spacing of side face reinforcement shall not exceed [ A ] 300 mm [ B ] Web thickness [ C ] Lesser of (a) and (b) [ D ] Greater of (a) and (b)

Last Answer : [ C ] Lesser of (a) and (b)

Description : The minimum number of main steel bars provided in R.C.C. (A) Rectangular columns is 4 (B) Circular columns is 6 (C) Octagonal columns is 8 (D) All the above

Last Answer : Answer: Option D

Description : In order to avoid the material failure in a braced column, the clear distance between restraints should never exceed [ A ] 30 times the minimum dimensions of the column [ B ] 40 times the minimum ... 50 times the minimum dimensions of the column [ D ] 60 times the minimum dimensions of the column

Last Answer : [ D ] 60 times the minimum dimensions of the column

Description : A steel bar 20 mm in diameter simply-supported at its ends over a total span of 40 cm carries a  load at its centre. If the maximum stress induced in the bar is limited to N/mm2, the bending  strain energy stored in the ... (A) 411 N mm  (B) 511 N mm  (C) 611 N mm  (D) 711 N mm 

Last Answer : (C) 611 N mm 

Description : A jet of water discharging from a 40 mm diameter orifice has a diameter of 32 mm at its vena contracta. The coefficient of contraction is (A) 0.46 (B) 0.64 (C) 0.78 (D) 0.87

Last Answer : Answer: Option B

Description : The diameter of the Vicat plunger is 10 mm and its length varies from (A) 20 mm to 30 mm (B) 30 mm to 40 mm (C) 40 mm to 50 mm (D) 50 mm to 60 mm

Last Answer : Answer: Option C

Description : The diameter of the Vicat plunger is 10 mm and its length varies form [ A ] 40 mm [ B ] 50 mm [ C ] 55 mm [ D ] 60 mm

Last Answer : [ B ] 50 mm

Description : A load of 1960 N is raised at the end of a steel wire. The minimum diameter of the wire so that  stress in the wire does not exceed 100 N/mm2  is:  (A) 4.0 mm  (B) 4.5 mm  (C) 5.0 mm  (D) 5.5 mm

Last Answer : (C) 5.0 mm 

Description : The minimum water content at which the soil just begins to crumble when rolled into threads 3 mm in diameter, is known (A) Liquid limit (B) Plastic limit (C) Shrinkage limit (D) Permeability limit

Last Answer : (B) Plastic limit

Description : The minimum diameter of longitudinal bars in a column is (A) 6 mm (B) 8 mm (C) 12 mm (D) 16 mm

Last Answer : Answer: Option C

Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four

Last Answer : Answer: Option D

Description : In any case, the minimum diameter of the link in a column, according to IS:456-2000 is [ A ] 5 mm [ B ] 6 mm [ C ] 8 mm [ D ] 10 mm

Last Answer : [ B ] 6 mm

Description : The minimum diameter of longitudinal steel should be [ A ] 10 mm [ B ] 12 mm [ C ] 16 mm [ D ] 20 mm

Last Answer : [ B ] 12 mm

Description : In slump test, each layer of concrete is compacted by a steel rod 60 cm long and of 16 mm diameter for (A) 20 times (B) 25 times (C) 30 times (D) 50 time

Last Answer : Answer: Option B

Description : An R.C.C. beam of 25 cm width and 50 cm effective depth has a clear span of 6 metres and carries a U.D.L. of 3000 kg/m inclusive of its self weight. If the lever arm constant for the section is 0.865, the maximum intensity ... , is (A) 8.3 kg/cm2 (B) 7.6 kg/cm2 (C) 21.5 kg/cm2 (D) 11.4 kg/cm2

Last Answer : Answer: Option A

Description : An R.C.C beam of 25 cm width has a clear span of 5 metres and carries a U.D.L. of 2000 kg/m inclusive of its self weight. If the lever arm of the section is 45 cm., the beam is ( ... shear (B) Is safe with stirrups (C) Is safe with stirrups and inclined members (D) Needs revision of the section

Last Answer : Answer: Option A

Description : According to IS:456-2000, the minimum eccentricity in no case [ A ] Shall be not less than 20mm [ B ] Shall be not greater than 30mm [ C ] Shall be 20mm-30mm [ D ] None of the above

Last Answer : [ A ] Shall be not less than 20mm

Description : If aggregates completely pass through a sieve of size 75 mm and are retained on a sieve of size 60 mm, the particular aggregate will be flaky if its minimum dimension is less than (A) 20.5 mm (B) 30.5 mm (C) 40.5 mm (D) 50.5 mm

Last Answer : Answer: Option C

Description : The diameter of hole for 20 dia rivet shall be a) 23 mm b) 18 mm c) 21.5 mm* d) 22 mm

Last Answer : c) 21.5 mm*

Description : A 600 mm square bearing plate settles by 15 mm in plate load test on a cohesion-less soil under an intensity of loading of 0.2 N/ram². The settlement of a prototype shallow footing 1 m square under the same intensity of ... (A) 15 mm (B) Between 15 mm and 25 mm (C) 25 mm (D) Greater than 25 mm

Last Answer : Answer: Option B

Description : The peak of a 4 hour flood hydrograph is 240 m3 /sec. If the rainfall excess is 80 mm and base flow which is constant is 40 m3 /sec, peak of 4hours unit hydrograph will be (A) 20 m3 /sec (B) 25 m3 /sec (C) 30 m3 /sec (D) 35 m3 /sec

Last Answer : Answer: Option B

Description : The maximum total settlement for raft foundation on clayey soils should be limited to (A) 25 mm (B) 25 to 40 mm (C) 40 to 65 mm (D) 65 to 100 mm

Last Answer : Answer: Option D