Description : For a longitudinal reinforcing bar in a column, the minimum cover shall neither be less than the diameter of bar nor less than (A) 15 mm (B) 25 mm (C) 30 mm (D) 40 mm
Last Answer : Answer: Option D
Description : The minimum thickness of the cover at the end of a reinforcing bar should not be less than twice the diameter of the bar subject to a minimum of (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm
Description : Minimum clear cover (in mm) to the main steel bars in slab, beam, column and footing respectively, are (a) 10, 15, 20 and 25 (b) 15, 25, 40 and 75 (c ) 20, 25, 30 and 40 (d) 20, 35, 40 and 75
Last Answer : (b) 15, 25, 40 and 75
Description : The difference in the reservoir level and the lowest point of the water mains is 180 m. The expected pressure due to water hammer is 7.5 kg/cm2 in a pressure conduit of diameter 1 m. Assuming the efficiency of the ... , is (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm
Last Answer : (C) 20 mm
Description : Minimum cover to longitudinal steel in a column should be (if the diameter of bar, Ø> 12mm) [ A ] 25 mm [ B ] 30 mm [ C ] 40 mm [ D ] 50 mm
Last Answer : [ C ] 40 mm
Description : The clear cover in a simply supported slab should not be less than the diameter of the reinforcing bar (a) Correct (b) Incorrect’ (c) Not known (d) None of these
Last Answer : (a) Correct
Description : A reinforced concrete slab is 75 mm thick. The maximum size of reinforcement bar that can be used is (a) 6 mm diameter (b) 8 mm diameter (c) 10 mm diameter (d) 12 mm diameter
Last Answer : (b) 8 mm diameter
Description : If the diameter of the main reinforcement in a slab is 16 mm, the concrete cover to main bars is (A) 10 mm (B) 12 mm (C) 14 mm (D) 16 mm
Description : The minimum cover to the ties or spirals should not be less than (A) 15 mm (B) 20 mm (C) 25 mm (D) 50 mm
Last Answer : Answer: Option C
Description : The maximum diameter of a bar used in a ribbed slab, is (A) 12 mm (B) 6 mm (C) 20 mm (D) 22 mm
Description : The minimum clear cover for R.C.C. columns shall be (A) Greater of 40 mm or diameter (B) Smaller of 40 mm or diameter (C) Greater of 25 mm or diameter (D) Smaller of 25 mm or diameter
Description : The Minimum bar spacing should not be less than [ A ] Diameter of the largest bar [ B ] Maximum size of aggregate [ C ] Greater of diameter of the largest bar and maximum size of aggregate [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm
Last Answer : [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm
Description : Minimum cover for fire resistance for a given simply supported beam, when the fire rating is 1 hour--------- [ A ] 15 mm [ B ] 20 mm [ C ] 25 mm [ D ] 30 mm
Last Answer : [ B ] 20 mm
Description : For a continuous slab of 3 m × 3.5 m size, the minimum overall depth of slab to satisfy vertical deflection limits is (A) 50 mm (B) 75 mm (C) 100 mm (D) 120 mm
Last Answer : (B) 75 mm
Description : For a continuous slab of 3 m x 35 m size, the minimum overall depth of slab to satisfy vertical deflection limits is (a) 120 mm (b) 100 mm (c) 75 mm (d) 50 mm
Last Answer : (a) 120 mm
Description : An aggregate which passes through 25 mm I.S. sieve and is retained on 20 mm sieve, is said to be flaky if its least dimension is less than (A) 22.5 mm (B) 18.5 mm (C) 16.5 mm (D) 13.5 mm
Description : The diameter of ties in a column should be (A) More than or equal to one fourth of diameter of main bar (B) More than or equal to 5 mm (C) More than 5 mm but less than one-fourth of diameter of main bar (D) More than 5 mm and also more than one-fourth of diameter of main bar
Description : The Minimum amount of steel for Main reinforcement in slab should be (Fe 415- grade of steel) [ A ] 0.12 percent of gross cross sectional area [ B ] 0.15 percent of gross cross sectional area [ C ] 0.20 percent of gross cross sectional area [ D ] 0.25 percent of gross cross sectional area.
Last Answer : [ A ] 0.12 percent of gross cross sectional area
Description : Maximum heat dissipation occurs from a steel wire (k = 0.5 W/m. k) of 15 mm diameter exposed to air (h = 20W/m2.k), when the insulation thickness is __________ mm. (A) 15 (B) 25 (C) 10 (D) 30
Last Answer : (B) 25
Description : The maximum permissible size of aggregates to be used in casting the ribs of a slab, is (A) 5 mm (B) 7.5 mm (C) 10 mm (D) 15 mm
Description : A spring of mean radius 40 mm contains 8 action coils of steel (N = 80000 N/mm2 ), 4 mm in diameter. The clearance between the coils being 1 mm when unloaded, the minimum compressive load to remove the clearance, is (A) 25 N (B) 30 N (C) 35 N (D) 40 N
Last Answer : (C) 35 N
Description : A 600 mm square bearing plate settles by 15 mm in plate load test on a cohesion-less soil under an intensity of loading of 0.2 N/ram². The settlement of a prototype shallow footing 1 m square under the same intensity of ... (A) 15 mm (B) Between 15 mm and 25 mm (C) 25 mm (D) Greater than 25 mm
Last Answer : Answer: Option B
Description : If the width of a pavement slab is 7.5 m, thickness 20 cm and working stress 1400 kg/cm2 , spacing of 10 mm tie bars for the longitudinal joint, is (A) 10 cm (B) 20 cm (C) 30 cm (D) 40 cm
Description : I.S. Sieve Nos. 10 mm and 4.75 mm are generally used for grading of (A) Coarse aggregates (B) Fine aggregates (C) Neither (a) nor (b) (D) Both (a) and (b)
Description : For determining the ultimate bearing capacity of soil, the recommended size of a square bearing plate to be used in load plate test should be 30 to 75 cm square with a minimum thickness of (A) 5 mm (B) 10 mm (C) 15 mm (D) 25 mm
Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four
Description : Select the incorrect statement from the following [ A ] Reinforcing bars in a column should not be less than 12 mm in diameter [ B ] The number of longitudinal bars in a circular column should not ... The minimum percentage of longitudinal steel in columns should be 0.8% [ D ] None of the above
Last Answer : [ B ] The number of longitudinal bars in a circular column should not exceed four
Description : If W is total load per unit area on a panel, D is the diameter of the column head, L is the span in two directions, then the sum of the maximum positive bending moment and average of the negative bending moment for the design of the span ... (L + 2D/3)² (C) WL/10 (L - 2D/3)² (D) WL/12 (L - D/3)²
Description : Minimum spacing between horizontal parallel reinforcement of different sizes, should not be less than (A) One diameter of thinner bar (B) One diameter of thicker bar (C) Twice the diameter of thinner bar (D) None of these
Description : A steel bar 5 m × 50 mm is loaded with 250,000 N. If the modulus of elasticity of the material is 0.2 MN/mm2 and Poisson's ratio is 0.25, the change in the volume of the bar is: (A) 1.125 cm3 (B) 2.125 cm3 (C) 3.125 cm3 (D) 4.125 cm
Last Answer : (C) 3.125 cm
Description : The diameter of the column head support a flat slab, is generally kept (A) 0.25 times the span length (B) 0.25 times the diameter of the column (C) 4.0 cm larger than the diameter of the column (D) 5.0 cm larger than the diameter of the column
Last Answer : Option A
Description : The minimum range for sliding the focusing lens in the internal focusing telescope for focusing at all distances beyond 4 m is (A) 5 mm (B) 10 mm (C) 15 mm (D) 20 mm
Last Answer : (D) 20 mm
Description : Hydraulic mean depth (Dm) for a circular pipe of diameter 'D' flowing full is 0.25 D. For a circular channel, at Dm = 0.3 D, gives the condition for the maximum (A) Flow rate (B) Mean velocity (C) Both 'a' & 'b' (D) Neither 'a' nor 'b
Last Answer : (B) Mean velocity
Description : The raft slab is projected beyond the outer walls of the structure by (A) 5 to 10 cm (B) 15 to 20 cm (C) 25 to 30 cm (D) 30 to 45 cm
Description : Nominal Pipe Size (NPS) of a pipe less than 12 inches in diameter indicates its (A) Inner diameter (B) Outer diameter (C) Thickness (D) Neither inner nor outer diameter
Last Answer : (D) Neither inner nor outer diameter
Description : A bed of spherical particles (specific gravity 2.5) of uniform size 1500 μm is 0.5 m in diameter and 0.5 m high. In packed bed state, the porosity may be taken as 0.4. Ergun's equation for the above fluid-particle ... fluidisation velocity, VOM is (A) 12 mm/s (B) 16 mm/s (C) 24 mm/s (D) 28 mm/s
Last Answer : (B) 16 mm/s
Description : A steel bar 20 mm in diameter simply-supported at its ends over a total span of 40 cm carries a load at its centre. If the maximum stress induced in the bar is limited to N/mm2, the bending strain energy stored in the ... (A) 411 N mm (B) 511 N mm (C) 611 N mm (D) 711 N mm
Last Answer : (C) 611 N mm
Description : For a simply supported beam of span 15 m, the minimum effective depth to satisfy the vertical deflection limits should be (A) 600 mm (B) 750 mm (C) 900 mm (D) More than 1 m
Description : In any case, the minimum diameter of the link in a column, according to IS:456-2000 is [ A ] 5 mm [ B ] 6 mm [ C ] 8 mm [ D ] 10 mm
Last Answer : [ B ] 6 mm
Description : The minimum diameter of longitudinal steel should be [ A ] 10 mm [ B ] 12 mm [ C ] 16 mm [ D ] 20 mm
Last Answer : [ B ] 12 mm
Description : A cylinder is said to be thin if the ratio of its thickness and diameter, is less than (A) 1/25 (B) 1/20 (C) 1/15 (D) 1/10
Last Answer : (D) 1/10
Description : In Girder and Slab Bridges Danger level should be marked below bottom of girders/slabs for water way is > 6.10 < 12.2 m a) 300 mm b) 600 mm c) 450 mm* d) 500 mm
Last Answer : c) 450 mm*
Description : In general, the depth of slab should be ---------------- the minimum depth required for balanced section. [ A ] Equal to [ B ] Less than [ C ] Greater than [ D ] Half of
Last Answer : [ C ] Greater than
Description : Minimum vertical clearance (VC) for a slab/ girder bridges with discharge of 0-30 cumecs is a) 300 mm b) 1500 mm c) 1800 mm d) 600 mm*
Last Answer : d) 600 mm*
Description : In screen analysis, the notation +5 mm/-10 mm means particles passing through (A) 10 mm screen and retained on 5 mm screen (B) 5 mm screen and retained on 10 mm screen (C) Both 5 mm and 10 mm screens (D) Neither 5 mm nor 10 mm screen
Last Answer : (A) 10 mm screen and retained on 5 mm screen
Description : The main reinforcement of a R.C. slab consists of 10 mm bars at 100 mm spacing; if it is desired to replace the 10 mm bars by 12 mm bars, then the spacing of 12mm bars should be (a) 120 mm (b) 140 mm (c ) 144 mm (d) 160mm
Last Answer : (c ) 144 mm
Description : The expected discharge to be obtained from an open well sunk in coarse sand is 0.0059 cumec. If the working depression head of the well is 3 m, the minimum diameter of the well, is (A) 2 m (B) 2.25 m (C) 2.50 m (D) 3.00 m
Last Answer : (D) 3.00 m
Description : For efficient working of a sewer, it must be ensured that A. Minimum velocity of 0.45 m/sec, is maintained at its minimum flow B. A maximum velocity of 0.90 m/sec, is maintained at its maximum flow C. Both A. and B. D. Neither A. nor B.
Last Answer : ANS: C
Description : In case of foundations on sandy soil, maximum permissible differential settlement, is usually limited to (A) 15 mm (B) 25 mm (C) 35 mm (D) 45 mm