The diameter of main bars in R.C.C. columns, shall not be less than
(A) 6 mm
(B) 8 mm
(C) 10 mm
(D) 12 mm

1 Answer

Answer :

Answer: Option D

Related questions

Description : Select the incorrect statement from the following [ A ] Reinforcing bars in a column should not be less than 12 mm in diameter [ B ] The number of longitudinal bars in a circular column should not ... The minimum percentage of longitudinal steel in columns should be 0.8% [ D ] None of the above

Last Answer : [ B ] The number of longitudinal bars in a circular column should not exceed four

Description : The diameter of longitudinal bars of a column should never be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm

Last Answer : Answer: Option D

Description : The minimum clear cover for R.C.C. columns shall be (A) Greater of 40 mm or diameter (B) Smaller of 40 mm or diameter (C) Greater of 25 mm or diameter (D) Smaller of 25 mm or diameter

Last Answer : Answer: Option C

Description : An R.C.C. column of 30 cm diameter is reinforced with 6 bars 12 mm placed symmetrically along the circumference. If it carries a load of 40, 000 kg axially, the stress is (A) 49.9 kg/cm2 (B) 100 kg/cm2 (C) 250 kg/cm2 (D) 175 kg/cm

Last Answer : Answer: Option A

Description : The diameter of transverse reinforcement of columns should be equal to one-fourth of the diameter of the main steel rods but not less than (A) 4 mm (B) 5 mm (C) 6 mm (D) 7 mm

Last Answer : Answer: Option D

Description : The minimum number of main steel bars provided in R.C.C. (A) Rectangular columns is 4 (B) Circular columns is 6 (C) Octagonal columns is 8 (D) All the above

Last Answer : Answer: Option D

Description : If the diameter of the main reinforcement in a slab is 16 mm, the concrete cover to main bars is (A) 10 mm (B) 12 mm (C) 14 mm (D) 16 mm

Last Answer : Answer: Option D

Description : If the diameter of longitudinal bars of a square column is 16 mm, the diameter of lateral ties should not be less than (A) 4 mm (B) 5 mm (C) 6 mm (D) 8 mm

Last Answer : Answer: Option B

Description : The minimum diameter of longitudinal bars in a column is (A) 6 mm (B) 8 mm (C) 12 mm (D) 16 mm

Last Answer : Answer: Option C

Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four

Last Answer : Answer: Option D

Description : The main reinforcement of a R.C. slab consists of 10 mm bars at 100 mm spacing; if it is desired to replace the 10 mm bars by 12 mm bars, then the spacing of 12mm bars should be (a) 120 mm (b) 140 mm (c ) 144 mm (d) 160mm

Last Answer : (c ) 144 mm

Description : A compound bar consists of two bars of equal length. Steel bar cross-section is 3500 mm2 and that  of brass bar is 3000 mm2 . These are subjected to a compressive load 100,000 N. If Eb = 0.2  MN/mm2  and Eb = 0.1 ... 6 N/mm2 s  = 12 N/mm2 (D) b = 5 N/mm2 s  = 10 N/mm

Last Answer : (A) b = 10 N/mm2 s  = 20 N/mm

Description : For a longitudinal reinforcing bar in a column, the minimum cover shall neither be less than the diameter of bar nor less than (A) 15 mm (B) 25 mm (C) 30 mm (D) 40 mm

Last Answer : Answer: Option D

Description : The purpose of lateral ties in short R.C. columns is to (a) Increase the load carrying capacity of column (b) Facilitate compaction of concrete (c) Facilitate construction (d) Avoid buckling of longitudinal bars

Last Answer : (d) Avoid buckling of longitudinal bars

Description : The Pitch of helixes in circular columns shall not exceed [ A ] 25 mm [ B ] 50 mm [ C ] 60 mm [ D ] 75 mm

Last Answer : [ D ] 75 mm

Description : Lapped splices in tensile reinforcement are generally not used for bars of size larger than (A) 18 mm diameter (B) 24 mm diameter (C) 30 mm diameter (D) 36 mm diameter

Last Answer : Answer: Option D

Description : The diameter of the stirrups according to IS : 456-2000 should not be less than [ A ] 5 mm [ B ] 6 mm [ C ] 8 mm [ D ] 10 mm

Last Answer : [ B ] 6 mm

Description : A reinforced concrete slab is 75 mm thick. The maximum size of reinforcement bar that can be used is (a) 6 mm diameter (b) 8 mm diameter (c) 10 mm diameter (d) 12 mm diameter

Last Answer : (b) 8 mm diameter

Description : If the size of a column is reduced above the floor, the main bars of the columns, are (A) Continued up (B) Bent inward at the floor level (C) Stopped just below the floor level and separate lap bars provided (D) All the above

Last Answer : Answer: Option D

Description : Minimum clear cover (in mm) to the main steel bars in slab, beam, column and footing respectively, are (a) 10, 15, 20 and 25 (b) 15, 25, 40 and 75 (c ) 20, 25, 30 and 40 (d) 20, 35, 40 and 75

Last Answer : (b) 15, 25, 40 and 75

Description : The diameter of bars for main reinforcement in slabs, may be (a) 2 to 4mm (b) 4 to 8mm (c) 8 to 14mm (d) 14 to 18mm

Last Answer : (c) 8 to 14mm

Description : The diameter of ties in a column should be (A) More than or equal to one fourth of diameter of main bar (B) More than or equal to 5 mm (C) More than 5 mm but less than one-fourth of diameter of main bar (D) More than 5 mm and also more than one-fourth of diameter of main bar

Last Answer : Answer: Option D

Description : The ratio of the diameter of reinforcing bars and the slab thickness is (A) 1/4 (B) 1/5 (C) 1/6 (D) 1/8

Last Answer : (D) 1/8

Description : Bottom bars under the columns are extended into the interior of the footing slab to a distance greater than (A) 42 diameters from the centre of the column (B) 42 diameters from the inner edge of ... ) 42 diameters from the outer edge of the column (D) 24 diameters from the centre of the column

Last Answer : Answer: Option C

Description : An R.C.C. beam of 6 m span is 30 cm wide and has a lever arm of 55 cm. If it carries a U.D.L. of 12 t per m and allowable shear stress is 5 kg/cm2 , the beam (A) Is safe in shear (B) Is safe with stirrups (C) Is safe with stirrups and inclined bars (D) Needs revision of section

Last Answer : Answer: Option D

Description : The development length of bars in compression is taken as [ A ] 30 times bar diameter [ B ] 40 times bar diameter [ C ] 50 times bar diameter [ D ] 12 times bar diameter

Last Answer : [ A ] 30 times bar diameter

Description : End anchorage of bars is taken as the greater of [ A ] Effective depth or 12 times the diameter of bar [ B ] Effective depth or 16 times the diameter of bar [ C ] Effective depth of 24 times the diameter of bar [ D ] Effective depth of 48 times the diameter of bar

Last Answer : [ A ] Effective depth or 12 times the diameter of bar

Description : The development length of bars in compression is taken as [ A ] 30 times bar diameter [ B ] 40 times bar diameter [ C ] 50 times bar diameter [ D ] 12 times bar diameter

Last Answer : [ A ] 30 times bar diameter

Description : End anchorage of bars is taken as the greater of [ A ] Effective depth or 12 times the diameter of bar [ B ] Effective depth or 16 times the diameter of bar [ C ] Effective depth of 24 times the diameter of bar [ D ] Effective depth of 48 times the diameter of bar

Last Answer : [ A ] Effective depth or 12 times the diameter of bar

Description : Top bars are extended to the projecting parts of the combined footing of two columns Ldistance apart for a distance of (A) 0.1 L from the outer edge of column (B) 0.1 L from the centre edge of column (C) Half the distance of projection (D) One-fourth the distance of projection

Last Answer : Answer: Option B

Description : The purpose of lateral ties in short reinforced concrete columns is to [ A ] Facilitate construction [ B ] Facilitate compaction of concrete [ C ] Increase the load carrying capacity of the columns [ D ] Avoid buckling of longitudinal bars

Last Answer : [ D ] Avoid buckling of longitudinal bars

Description : The breadth of a ribbed slab containing two bars must be between (A) 6 cm to 7.5 cm (B) 8 cm to 10 cm (C) 10 cm to 12 cm (D) 12 cm to 15 cm

Last Answer : Answer: Option B

Description : In any case, the minimum diameter of the link in a column, according to IS:456-2000 is [ A ] 5 mm [ B ] 6 mm [ C ] 8 mm [ D ] 10 mm

Last Answer : [ B ] 6 mm

Description : The diameter of pipes in bath rooms and lavatories in domestic water supply, is (A) 6 mm (B) 12 mm (C) 18 mm (D) 24 mm

Last Answer : (B) 12 mm

Description : The maximum diameter of a bar used in a ribbed slab, is (A) 12 mm (B) 6 mm (C) 20 mm (D) 22 mm

Last Answer : Answer: Option D

Description : The minimum thickness of the cover at the end of a reinforcing bar should not be less than twice the diameter of the bar subject to a minimum of (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm

Last Answer : Answer: Option D

Description : The minimum cover in a slab should neither be less than the diameter of bar nor less than (A) 10 mm (B) 15 mm (C) 25 mm (D) 13 mm

Last Answer : Answer: Option B

Description : The minimum diameter of longitudinal steel should be [ A ] 10 mm [ B ] 12 mm [ C ] 16 mm [ D ] 20 mm

Last Answer : [ B ] 12 mm

Description : If the width of a pavement slab is 7.5 m, thickness 20 cm and working stress 1400 kg/cm2 , spacing of 10 mm tie bars for the longitudinal joint, is (A) 10 cm (B) 20 cm (C) 30 cm (D) 40 cm

Last Answer : Answer: Option C

Description : The diameter of bars used for distribution reinforcement in slabs, may vary from (a) 2 to 4mm (b) 4 to 6mm (c) 6mm to 8mm (d) 8 to 12mm

Last Answer : (c) 6mm to 8mm

Description : The spacing of bars of perforations of fine screens used for the treatment of sewage, is A. 2 to 3 mm B. 3 to 5 mm C. 5 to 8 mm D. 8 to 10 mm

Last Answer : ANS: A

Description : Lap splicing are not usually allowed for bars more than [ A ] 25 mm [ B ] 32 mm [ C ] 36 mm [ D ] None of the above

Last Answer : [ C ] 36 mm

Description : Lap splicing are not usually allowed for bars more than [ A ] 25 mm [ B ] 32 mm [ C ] 36 mm [ D ] None of the above

Last Answer : [ C ] 36 mm

Description : A bed of spherical particles (specific gravity 2.5) of uniform size 1500 μm is 0.5 m in diameter and 0.5 m high. In packed bed state, the porosity may be taken as 0.4. Ergun's equation for the above fluid-particle ... fluidisation velocity, VOM is (A) 12 mm/s (B) 16 mm/s (C) 24 mm/s (D) 28 mm/s

Last Answer : (B) 16 mm/s

Description : The percentage of reinforcement in case of slabs, when high strength deformed bars are used is not less than (A) 0.15 (B) 0.12 (C) 0.30 (D) 1.00

Last Answer : Answer: Option B

Description : The Minimum bar spacing should not be less than [ A ] Diameter of the largest bar [ B ] Maximum size of aggregate [ C ] Greater of diameter of the largest bar and maximum size of aggregate [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm

Last Answer : [ D ] Greater of diameter of the largest bar and maximum size of aggregate plus 5 mm

Description : The diameter of hole for 20 dia rivet shall be a) 23 mm b) 18 mm c) 21.5 mm* d) 22 mm

Last Answer : c) 21.5 mm*

Description : The difference in the reservoir level and the lowest point of the water mains is 180 m. The  expected pressure due to water hammer is 7.5 kg/cm2  in a pressure conduit of diameter 1 m.  Assuming the efficiency of the ... , is  (A) 10 mm  (B) 15 mm  (C) 20 mm  (D) 25 mm 

Last Answer : (C) 20 mm

Description : The tensile force required to cause an elongation of 0.045 mm in a steel rod of 1000 mm length and 12 mm diameter, is (where E = 2 × 106 kg/cm2 ) (A) 166 kg (B) 102 kg (C) 204 kg (D) 74 kg

Last Answer : (B) 102 kg

Description : The concrete slump recommended for columns, is (A) 25 to 50 mm (B) 25 to 75 mm (C) 75 to 125 mm (D) 50 to 100 mm

Last Answer : Answer: Option C