Lap splicing are not usually allowed for bars more than
[ A ] 25 mm
[ B ] 32 mm
[ C ] 36 mm
[ D ] None of the above

1 Answer

Answer :

[ C ] 36 mm

Related questions

Description : Lap splicing are not usually allowed for bars more than [ A ] 25 mm [ B ] 32 mm [ C ] 36 mm [ D ] None of the above

Last Answer : [ C ] 36 mm

Description : Lapped splices in tensile reinforcement are generally not used for bars of size larger than (A) 18 mm diameter (B) 24 mm diameter (C) 30 mm diameter (D) 36 mm diameter

Last Answer : Answer: Option D

Description : Minimum clear cover (in mm) to the main steel bars in slab, beam, column and footing respectively, are (a) 10, 15, 20 and 25 (b) 15, 25, 40 and 75 (c ) 20, 25, 30 and 40 (d) 20, 35, 40 and 75

Last Answer : (b) 15, 25, 40 and 75

Description : If the size of a column is reduced above the floor, the main bars of the columns, are (A) Continued up (B) Bent inward at the floor level (C) Stopped just below the floor level and separate lap bars provided (D) All the above

Last Answer : Answer: Option D

Description : The length of lap in tension reinforcement should not be less than the bar diameter × (actual tension / four times the permissible average bond stress) if it is more than (A) 18 bar diameters (B) 24 bar diameters (C) 30 bar diameters (D) 36 bar diameters

Last Answer : Answer: Option C

Description : Number of commutator bars for a 4-pole, 2-layer, DC lap winding with 24 slots and one conductor per layer is (A) 48 (B) 24 (C) 192 (D) 96

Last Answer : Number of commutator bars for a 4-pole, 2-layer, DC lap winding with 24 slots and one conductor per layer is 24

Description : The diameter of longitudinal bars of a column should never be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm

Last Answer : Answer: Option D

Description : If the diameter of longitudinal bars of a square column is 16 mm, the diameter of lateral ties should not be less than (A) 4 mm (B) 5 mm (C) 6 mm (D) 8 mm

Last Answer : Answer: Option B

Description : The diameter of main bars in R.C.C. columns, shall not be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm

Last Answer : Answer: Option D

Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four

Last Answer : Answer: Option D

Description : Select the incorrect statement from the following [ A ] Reinforcing bars in a column should not be less than 12 mm in diameter [ B ] The number of longitudinal bars in a circular column should not ... The minimum percentage of longitudinal steel in columns should be 0.8% [ D ] None of the above

Last Answer : [ B ] The number of longitudinal bars in a circular column should not exceed four

Description : In case of foundations on sandy soil, maximum permissible differential settlement, is usually limited to (A) 15 mm (B) 25 mm (C) 35 mm (D) 45 mm

Last Answer : Answer: Option B

Description : If a concrete column 200 200 mm in cross-section is reinforced with four steel bars of 1200  mm2  total cross-sectional area. Calculate the safe load for the column if permissible stress in  concrete is 5 N/mm2 ... 15 Ec (A) 264 MN  (B) 274 MN  (C) 284 MN  (D) 294 MN 

Last Answer : (C) 284 MN 

Description : A compound bar consists of two bars of equal length. Steel bar cross-section is 3500 mm2 and that  of brass bar is 3000 mm2 . These are subjected to a compressive load 100,000 N. If Eb = 0.2  MN/mm2  and Eb = 0.1 ... 6 N/mm2 s  = 12 N/mm2 (D) b = 5 N/mm2 s  = 10 N/mm

Last Answer : (A) b = 10 N/mm2 s  = 20 N/mm

Description : An R.C.C. column of 30 cm diameter is reinforced with 6 bars 12 mm placed symmetrically along the circumference. If it carries a load of 40, 000 kg axially, the stress is (A) 49.9 kg/cm2 (B) 100 kg/cm2 (C) 250 kg/cm2 (D) 175 kg/cm

Last Answer : Answer: Option A

Description : If the diameter of the main reinforcement in a slab is 16 mm, the concrete cover to main bars is (A) 10 mm (B) 12 mm (C) 14 mm (D) 16 mm

Last Answer : Answer: Option D

Description : If the width of a pavement slab is 7.5 m, thickness 20 cm and working stress 1400 kg/cm2 , spacing of 10 mm tie bars for the longitudinal joint, is (A) 10 cm (B) 20 cm (C) 30 cm (D) 40 cm

Last Answer : Answer: Option C

Description : The minimum diameter of longitudinal bars in a column is (A) 6 mm (B) 8 mm (C) 12 mm (D) 16 mm

Last Answer : Answer: Option C

Description : The main reinforcement of a R.C. slab consists of 10 mm bars at 100 mm spacing; if it is desired to replace the 10 mm bars by 12 mm bars, then the spacing of 12mm bars should be (a) 120 mm (b) 140 mm (c ) 144 mm (d) 160mm

Last Answer : (c ) 144 mm

Description : The Maximum spacing of the longitudinal bars measured long the periphery of the column should be [ A ] 250 mm [ B ] 300 mm [ C ] 400 mm [ D ] 450 mm

Last Answer : [ B ] 300 mm

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50'. What number is missing? -Riddles

Last Answer : 22

Description : The mean of 25 observations is 36. Out of these observations, if the mean of first 13 observations is 32 and that of the last 13 observations is 40, the 13th observation is -Maths 9th

Last Answer : NEED ANSWER

Description : The mean of 25 observations is 36. Out of these observations, if the mean of first 13 observations is 32 and that of the last 13 observations is 40, the 13th observation is -Maths 9th

Last Answer : (b) Given, mean of 25 observations = 36 ∴ Sum of 25 observations = 36 x 25 = 900 Now, the mean of first 13 observations = 32 ∴ Sum of first 13 observations = 13 x 32 = 416 and the mean of last 13 ... - (Sum of 25 observations) = (520 + 416)-900 = 936 - 900 = 36 Hence, the 13th observation is 36.

Description : The spacing between the discs in the gang bolt ranges cm for lighy duty and cm heavy -duty harrows i. 15-25 and 25-30 c) 40-45 and 45-50 ii. 20-30 and 30-40. d) 15-25 and 32-36

Last Answer : 15-25 and 25-30

Description : 1:1, 8:4, 9:27, 64:16, 25:125, ?:?, 49:343, a) 36:316 b) 216:36 c) 316:16 d) 32:316 e) None of these

Last Answer : Its alternatively ratio of n2 and n3 Now, after 25:125, it would be 63 : 62  216:36 Answer: b)

Description : A square object of 4 mm is subjected to a force of 3000 N. What is the maximum allowable shear stress acting on it? a. 250.14 mm2 b. 281.25 mm2 c. 400.32 mm2 d. 500 mm2

Last Answer : b. 281.25 mm2

Description : For high level flush the nominal dia of flush pipe shall be (a) 32 mm* (b) 40 mm (c) 25 mm (d) None of these

Last Answer : a) 32 mm*

Description : The length of bar necessary to develop the full strength of the bar is called [ A ] Bond [ B ] Development length [ C ] End anchorage [ D ] Splicing

Last Answer : [ B ] Development length

Description : The length of bar necessary to develop the full strength of the bar is called [ A ] Bond [ B ] Development length [ C ] End anchorage [ D ] Splicing

Last Answer : [ B ] Development length

Description : If 20 kg of coarse aggregate is sieved through 80 mm, 40 mm, 20 mm, 10 mm, 4.75 mm, 2.36 mm, 1.18 mm, 600 micron, 300 micron and 150 micron standard sieves and the weights retained are 0 kg, 2 kg, 8 kg, ... , the fineness modulus of the aggregate, is (A) 7.30 (B) 7.35 (C) 7.40 (D) 7.45

Last Answer : Answer: Option C

Description : Which of the following ranges identifies the amount of pressure within the endotracheal tube cuff that is believed to prevent both injury and aspiration? a) 20-25 mm Hg water pressure. Usually the ... pressure A measure of 0-5 mm Hg water pressure would indicate that the cuff is underinflated.

Last Answer : a) 20-25 mm Hg water pressure. Usually the pressure is maintained at less than 25 cm water pressure to prevent injury and at more than 20 cm water pressure to prevent aspiration.

Description : A short masonry pillar is 60 cm x 60 cm in cross-section, the core of the pillar is a square whose side is (A) 17.32 cm (B) 14.14 cm (C) 20.00 cm (D) 22.36 cm

Last Answer : (B) 14.14 cm

Description : The minimum thickness of a flat slab is taken (A) L/32 for end panels without drops (B) L/36 for end panels without drops (C) L/36 for interior panels without drop (D) All the above

Last Answer : Answer: Option D

Description : A jet of water discharging from a 40 mm diameter orifice has a diameter of 32 mm at its vena contracta. The coefficient of contraction is (A) 0.46 (B) 0.64 (C) 0.78 (D) 0.87

Last Answer : Answer: Option B

Description : For constructing a terrazzo floor, Pick up the incorrect statement from the following: (A) A base course is prepared as in cement concrete flooring (B) A 32 mm thick layer of cement concrete ... final grinding is over, oxalic acid mixed with water is spread over and rubbed hard with soft material

Last Answer : Answer: Option B

Description : When smoking was allowed in bars would the beer or hard alcohol chatch on fire?

Last Answer : They didn't catch from smoking, but very aromatic liquors can be lit with a high temperature flame. That's how flambé desserts work, pour brandy and light on fire. There are known cases of ... spontaneously combusting from a flame or a cigarette. The alcohol ignites and the fat burns like a candle.

Description : Should bars be allowed to ”boot” vehicles of those too inebriated to drive?

Last Answer : answer:No. They should not be serving someone that visibly drunk. But putting a boot on the car means a designated driver can't drive the car home. It's not the tavern's car, and not tavern ... to drive again. If someone is threatening to drive drunk, the bartender can threaten to call the police.

Description : The spacing of bars of perforations of fine screens used for the treatment of sewage, is A. 2 to 3 mm B. 3 to 5 mm C. 5 to 8 mm D. 8 to 10 mm

Last Answer : ANS: A

Description : The spacing of bars for perforations in coarse screens used for the treatment of sewage, is A. 20 mm B. 30 mm C. 40 mm D. 50 mm

Last Answer : ANS: D

Description : The unit of pressure in S.I. units is  (a) kg/cm2  (b) mm of water column  (c) pascal  (d) dynes per square cm  (e) bars

Last Answer : Answer : c

Description : safety belts usually consist of a lap belt and __________. -General Knowledge

Last Answer : Safety belts usually consist of a lap belt and a Shoulder Belt.

Description : The detention period for plain sedimentation water tanks, is usually  (A) 4 to 8 hours  (B) 8 to 16 hours  (C) 16 to 24 hours  (D) 24 to 36 hours

Last Answer : (D) 24 to 36 hours

Description : The maximum permissible differential settlement, in case of foundations in clayey soil, is usually limited to (A) 10 mm (B) 20 mm (C) 30 mm (D) 40 mm

Last Answer : Answer: Option D

Description : A 600 mm square bearing plate settles by 15 mm in plate load test on a cohesion-less soil under an intensity of loading of 0.2 N/ram². The settlement of a prototype shallow footing 1 m square under the same intensity of ... (A) 15 mm (B) Between 15 mm and 25 mm (C) 25 mm (D) Greater than 25 mm

Last Answer : Answer: Option B

Description : The minimum thickness of the cover at the end of a reinforcing bar should not be less than twice the diameter of the bar subject to a minimum of (A) 10 mm (B) 15 mm (C) 20 mm (D) 25 mm

Last Answer : Answer: Option D

Description : An aggregate which passes through 25 mm I.S. sieve and is retained on 20 mm sieve, is said to be flaky if its least dimension is less than (A) 22.5 mm (B) 18.5 mm (C) 16.5 mm (D) 13.5 mm

Last Answer : Answer: Option D

Description : The minimum cover to the ties or spirals should not be less than (A) 15 mm (B) 20 mm (C) 25 mm (D) 50 mm

Last Answer : Answer: Option C

Description : For a longitudinal reinforcing bar in a column, the minimum cover shall neither be less than the diameter of bar nor less than (A) 15 mm (B) 25 mm (C) 30 mm (D) 40 mm

Last Answer : Answer: Option D

Description : The minimum cover in a slab should neither be less than the diameter of bar nor less than (A) 10 mm (B) 15 mm (C) 25 mm (D) 13 mm

Last Answer : Answer: Option B