Which of the following is a boiler accessory i.e., not a boiler mounting? (A) Blow off cock
(B) Feed check valve
(C) Feed water pump
(D) Stop valve

1 Answer

Answer :

(C) Feed water pump

Related questions

Description : . Name the safety device used to protect the boiler, when the water level falls below a minimum level. (A) Blow down valve (B) Blow off cock (C) Fusible plug (D) Safety valve

Last Answer : (C) Fusible plug

Description : Blow off cock is provided in steam boiler to (A) Guard the boiler in case of abnormal rise in steam pressure (B) Drain out water and sludge during its repair (C) Regulate the supply of water in boiler (D) Put out the fire in the furnace when the water level in the boiler falls to unsafe limit

Last Answer : (B) Drain out water and sludge during its repair

Description : The valve commonly used in pipes larger than 2" dia is a (A) Globe valve (B) Plug-cock (C) Gate valve (D) Check valve

Last Answer : (C) Gate valve

Description : Check in a centrifugal pump is (A) Provided in the discharge line (B) Generally a globe valve (C) Provided to prevent liquid from backing up through the pump when the pump is turned off or accidently stops running (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Can I blow horse cock I m just wondering?

Last Answer : 380 to 550 kilograms

Description : Boiler feed water pump is usually a __________ pump. (A) Reciprocating (B) Gear (C) Multistage centrifugal (D) Diaphragm

Last Answer : (C) Multistage centrifugal

Description : The delivery pressure of boiler feed water pump compared to the boiler steam pressure is (A) Same (B) Slightly less (C) Slightly more (D) Much more

Last Answer : (C) Slightly more

Description : Where is water steam separator drum located in Lamont boiler ? a. Inside of the boiler b. Right above the furnace c. Before the feed water pump d. Outside the boiler

Last Answer : d. Outside the boiler

Description : Through which does the even circulation of water is possible in Lamont boiler ? a. Nozzles b. Water trough c. Feed pump d. Hose

Last Answer : a. Nozzles

Description : Through what is feed water from hot-well is passed through, before entering steam and water drum in Lamont boiler? a. Evaporator tubes b. Economizer c. Distributor header d. Circulating pump

Last Answer : b. Economizer

Description : Which of the following options will facilitate the achievement of a very high head (say 30 metres) in case of a centrifugal pump? (A) Increasing the impeller speed and the volute area (B) Increasing the number of vanes ... or more impellers in series on a single shaft (D) Either of (A), (B) or (C)

Last Answer : (C) Mounting of two or more impellers in series on a single shaft

Description : Check valve provided in the discharge line of a centrifugal pump serves the purpose of controlling the (A) Back flow of fluid in the event of stoppage of pump (B) Discharge pressure (C) Flow of liquid during operation of the pump (D) All (A), (B) and (C)

Last Answer : (A) Back flow of fluid in the event of stoppage of pump

Description : Which of the following is the combustion accessory of a boiler? • Fuel oil system • Gas system • Coal system • All of the above

Last Answer : • All of the above

Description : 1998 Volkswagen jetta VR6, where is my blow off valve stock?

Last Answer : Is it the 1.9, 2.0 , or 2.8?

Description : What are blow off valve?

Last Answer : Answer: It is a variety of globe valve confirming with boiler code requirements and specially designed for boiler blowoff service. WYE pattern and angle type, used to remove air and other gases from boilers etc.

Description : Why Does The Safety Valve On My Tank Blow Off?

Last Answer : This is caused by a pressure switch improperly installed, set too high or malfunctioning. Safety valves do not normally fail on their own.

Description : Erosion and pits formation on the impeller of a centrifugal pump may be due to (A) Cavitation (B) Low speed of impeller (C) Its operation with delivery valve closed for considerable time after starting the pump (D) Off centering of pump with motor

Last Answer : (A) Cavitation

Description : What is the function of a stop cock?

Last Answer : If you suffer a burst water pipe, you would use the stop cock to shut off the water until you can have the burst pipe repaired. The stop cock is simply a valve that you can manually turn on or ... When things go wrong with your water supply inside your home, you can't have too many water stop cocks!

Description : Which of the following option is incorrect about the sludges? a) Sludges are soft, loose and slimy precipitate b) They are non-adherent deposits and can be easily removed c) Formed generally at heated portions of the boiler d) Can be removed by blow down operation

Last Answer : c) Formed generally at heated portions of the boiler

Description : Pick up the correct statement from the following: (A) At a particular speed of operation, the head produced decreases with the increase of discharge (B) At zero discharge, discharge valve remaining closed ... which efficiency of a pump is maximum, is known as normal discharge (D) All the above

Last Answer : (D) All the above

Description : When does the engine High Pressure fuel shut off valve close? a. After a booster pump failure b. When the engine fuel switch is selected ‘ON’ during engine start c. When flight idle is selected d. When the engine fuel switch is selected ‘OFF’ during engine shut-down

Last Answer : d. When the engine fuel switch is selected ‘OFF’ during engine shut-down

Description : When does the engine High Pressure fuel shut off valve close? a. After a booster pump failure b. When the engine fuel switch is selected ‘ON’ during engine start c. When flight idle is selected d. When the engine fuel switch is selected ‘OFF’ during engine shut-down

Last Answer : d. When the engine fuel switch is selected ‘OFF’ during engine shut-down

Description : Why we never disconnect the tubing from the gas cock without first turning the gas off?

Last Answer : If the gas is not turned off first, on removing the tubing, gas will escape - very dangerous.

Description : Why we never disconnect the tubing from the gas cock without first turning the gas off?

Last Answer : If the gas is not turned off first, on removing the tubing, gas will escape - very dangerous.

Description : The hammer blow in pipes occurs when (A) There is excessive leakage in the pipe (B) The pipe bursts under high pressure of fluid (C) The flow of fluid through the pipe is suddenly brought to ... valve (D) The flow of fluid through the pipe is gradually brought to rest by closing of the valve

Last Answer : Answer: Option C

Description : Where stop check valve is used?

Last Answer : Answer: In stem generation by multiple boilers, where a valve is inserted between each boiler and the main steam header. It can be optionally closed automatically or normally.

Description : Steam condensate is recovered by steam traps and recycled for use as boiler feed water, because of its low (A) Hardness (B) Dissolved solids content (C) Suspended solids content (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Scale formation in boiler is controlled by (A) Preheating of feed water (B) Reduction in hardness, silica & alumina in feed water (C) Keeping the pH value of feed water just below 7 (D) Eliminating H2S in feed water

Last Answer : (B) Reduction in hardness, silica & alumina in feed water

Description : Pick out the wrong statement. (A) Caustic embrittlement of boiler's metallic parts is caused by highconcentration of caustic soda in boiler feed water (B) Cooling and freezing of water kills the ... goes on decreasing (D) Dissolved oxygen content in high pressure boiler feed water should be nil

Last Answer : (B) Cooling and freezing of water kills the bacteria present in it

Description : Foaming and priming in boiler operation can be reduced by reduction in __________ in feed water. (A) Turbidity (B) Color (Hazen) (C) Total solids (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : In the context of the chemical process industries, the term BOD is normally associated with the (A) Characterisation of solid wastes (B) Organic concentration in gaseous effluents (C) Characterisation of liquid effluents (D) Characterisation of boiler feed water

Last Answer : (C) Characterisation of liquid effluents

Description : Deaeration of high pressure boiler feed water is done to reduce (A) Foaming from boilers (B) Its dissolved oxygen content (C) Its silica content (D) Caustic embrittlement

Last Answer : (B) Its dissolved oxygen content

Description : Soluble silica present in boiler feed water can be removed by (A) Coagulation (B) Filtration (C) Anion exchanger (D) Preheating it

Last Answer : (C) Anion exchanger

Description : Widely used method for the conditioning of boiler feed water is the (A) Cold lime process (B) Coagulation (C) Hot-lime soda process (D) Sequestration

Last Answer : (C) Hot-lime soda process

Description : Which of the following impurities in feed water for high pressure boiler is the most detrimental? (A) Silica (B) Dissolved oxygen (C) Suspended salt (D) Dissolved salt

Last Answer : (A) Silica

Description : The most prominent single cause of corrosion in boiler-tubes, drums, economisers and steam superheaters in a thermal power plant boiler is the (A) Water alkalinity & leakage (B) Hydrazine addition during ... treatment (C) Release of non-condensable gas from water in the boiler (D) Scale formation

Last Answer : (C) Release of non-condensable gas from water in the boiler

Description : The most detrimental impurity in high pressure boiler feed water is (A) Suspended salt (B) Dissolved salt (C) Silica (D) Turbidity

Last Answer : Option C

Description : A device known as a _______ is used to release condensate from the pipework whilst preventing the steam from escaping from the system. a. Steam traps b. Steam pipes c. Boiler nose d. Release valve

Last Answer : a. Steam traps

Description : A spring of stiffness 100 N/mm used in a spring-loaded safety valve of diameter 20 mm on a boiler with the pressure inside the boiler equal to 1 MPa should be initially compressed by a. 5mm b. 3.14 mm c. 2mm d. 6.28 mm

Last Answer : b. 3.14 mm

Description : Foot valve provided in the pump is a __________ valve. (A) Direction control (B) Back pressure (C) Relief (D) Pressure reduction

Last Answer : (B) Back pressure

Description : While starting a centrifugal pump, its delivery valve should be kept (A) Opened (B) Closed (C) Either opened or closed; it does not make any difference (D) Either opened or closed; depending on the fluid viscosity

Last Answer : (B) Closed

Description : Gear pump (A) Is a positive displacement pump (B) Is a centrifugal pump (C) Is a non-positive displacement pump (D) Can be started with delivery valve closed

Last Answer : (A) Is a positive displacement pump

Description : While starting an axial flow pump, its delivery valve should be kept (A) Open (B) Closed (C) Either open or closed (D) None of these

Last Answer : (A) Open

Description : The vent valve provided in a liquid handling centrifugal pump is (A) Generally a needle valve (B) Used to release any gases that might be vapour locking the pump (C) Helpful in easy removal of samples (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : A relief valve (A) Provides back pressure for a cylinder (B) Unloads a pump (C) Is a directional control valve (D) None of these

Last Answer : (C) Is a directional control valve

Description : A hydraulic accumulator comprises of (A) A storage device and a control valve (B) A cylinder and a plunger (C) Two pistons and two cylinders (D) A storage tank and a ram pump

Last Answer : (B) A cylinder and a plunger

Description : Purpose of relief valve in a reciprocating pump is to (A) Protect the pump against developing excessive pressure (B) Facilitate unidirectional flow of liquid (C) Reduce the discharge pressure (D) Control the rate of discharge

Last Answer : (A) Protect the pump against developing excessive pressure

Description : What is called as the heart of the Lamont boiler? a. Water drum b. Centrifugal pump c. Furnace d. Blower

Last Answer : b. Centrifugal pump

Description : Water that is fed back to the boiler by the pump is called? a. Absorber b. Absolute c. Compressor d. Condensate

Last Answer : d. Condensate

Description : Recovery of waste heat from hot fluid to fluid is called: a) thermo compressor b) waste heat recovery boiler c) heat Pump d) economizer

Last Answer : heat Pump