Small pressure differences in liquids is measured using a/an
(A) U-tube manometer
(B) Inclined tube manometer
(C) Pitot tube
(D) None of these

1 Answer

Answer :

(B) Inclined tube manometer

Related questions

Description : Very small pressure difference (< 5 mm water column) can be most conveniently measured by a/an __________ manometer. (A) U-tube water (B) U-tube mercury (C) Inclined tube mercury (D) Inclined tube water

Last Answer : (D) Inclined tube water

Description : Working principle of manometer comprises of balancing a coloumn of liquid against the pressure to be measured. Inclined tube manometer is especially used for the measurement of __________ pressure. (A) Small differential (B) Atmospheric (C) Absolute (D) Gage

Last Answer : (A) Small differential

Description : Air velocity in ducts can be measured by using and manometer a) Orifice meter b) Borden gauge c) Pitot tube d) Anemometer

Last Answer : Pitot tube

Description : Flow rate of high velocity flue gas discharged through a stack to the atmosphere can be most conveniently measured by a (A) Pitot tube (B) Manometer (C) Rotameter (D) None of these

Last Answer : (A) Pitot tube

Description : Two liquids manometer is used for measuring small pressure differences in (A) Liquids (B) Gases (C) Mixture of hydrocarbons (D) None of these

Last Answer : (A) Liquids

Description : What instrument is used to measure atmospheric pressure?  A. Pitot tube  B. Wind vane  C. Barometer  D. Manometer

Last Answer : Barometer

Description : Which of the following is NOT an instrument used to measure pressure?  A. Bourdon tube  B. Pitot tube  C. Aneroid  D. Manometer

Last Answer : Pitot tube

Description : A Pitot tube indicates 5 cm of water (manometer) when it is being used for measuring velocity of air. The velocity of air in m/sec is (A) 5 (B) 14.1 (C) 56.22 (D) 28.2

Last Answer : (D) 28.2

Description : Which of the following manometer has highest sensitivity? (A) U-tube with water (B) Inclined U-tube (C) U-tube with mercury (D) Micro-manometer with water

Last Answer : Answer: Option D

Description : In order to increase sensitivity of U-tube manometer, one leg is usually inclined by angle . Sensitivity of inclined tube to sensitivity of U-tube is equal to (A) Sin (B) 1/Sin (C) Cos (D) 1/Cos

Last Answer : Answer: Option B

Description : Choose the wrong statement. Alcohol is used in manometer, because (A) Its vapour pressure is low (B) It provides suitable meniscus for the inclined tube (C) Its density is less (D) It provides longer length for a given pressure difference

Last Answer : Answer: Option A

Description : Pressure of the order of 10" torr can be measured by (A) Bourdon tube (B) Pirani Gauge (C) Micro-manometer (D) Lonisation gauge

Last Answer : Answer: Option D

Description : Water flow rate in a pipe of 3.5 metres diameter can be most economically and conveniently measured by a/an (A) Pitot tube (B) Venturimeter (C) Orificemeter (D) Rotameter

Last Answer : (A) Pitot tube

Description : Speed of a submarine in deep sea & that of an aeroplane is measured by a/an (A) Pitot tube (B) Hot wire anemometer (C) Rotameter (D) Stroboscope

Last Answer : (A) Pitot tube

Description : Flow of water in a pipe about 3 metres in diameter can be measured by (A) Orifice plate (B) Venturimeter (C) Rotameter (D) Pitot tube

Last Answer : Answer: Option D

Description : __________ is used for measuring the static pressure exerted on the wall by a fluid flowing parallel to the wall in a pipeline. (A) Venturimeter (B) Pressure gauge (C) Pitot tube (D) Orificemeter

Last Answer : (C) Pitot tube

Description : The simple Pitot tube measures the __________ pressure. (A) static (B) Dynamic (C) Total (D) None of these

Last Answer : (C) Total

Description : The simple Pitot tube does not measure the (A) Static pressure (B) Dynamic pressure (C) Velocity at the stagnation point (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The pressure head of a flow meter remains constant for (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : The Prandtl Pitot tube measures the (A) Velocity at a point in the flow (B) Pressure at a point (C) Average flow velocity (D) Pressure difference in pipe flow

Last Answer : (A) Velocity at a point in the flow

Description : The pitot static tube does not measure the __________ pressure. (A) Static (B) Total (C) Difference in static & dynamic (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : In a/an __________, the flow rate of fluids is obtained by measuring the difference between the impact and the static pressure. (A) Rotameter (B) Pitot tube (C) Venturimeter (D) Flow nozzle

Last Answer : (B) Pitot tube

Description : Compare U tube manometer and well type manometer

Last Answer : U-tube and well type manometer Sr.No. U-tube manometer well type manometer 1 Both legs are having same cross section area Both legs are having different cross section area ... cross section area. 5 Difference in heights in measured. Single height is measured.

Description : Pressure difference between two points in vessels, pipelines or in two different pipelines can be measured by a differential manometer. The pressure difference measured as the mm of water column in case of mercury-water, differential manometer is ... mm). (A) H (B) 12.6 H (C) 13.6 H (D) 14.6 H

Last Answer : (B) 12.6 H

Description : Correction for capillary effect in manometers (used for pressure measurement) need not be applied, if diameter of the manometer tube is __________ mm. (A) < 4 (B) > 4 (C) > 12.5 (D) < 10

Last Answer : (C) > 12.5

Description : Why is an inclined manometer used ?

Last Answer : It is used to extend the scale of the instrument. Because the manometer is at an angle to the vertical.

Description : Pitot tube is used for measurement of (A) Pressure (B) Flow (C) Velocity (D) Discharge

Last Answer : Answer: Option C

Description : Which of the following statement is wrong? (A) A flow whose streamline is represented by a curve is called two dimensional flow. (B) The total energy of a liquid particle is the sum of potential energy, ... (D) A pitot tube is used to measure the velocity of flow at the required point in a pipe.

Last Answer : Answer: Option C

Description : A pitot tube is used to measure the (A) Velocity of flow at the required point in a pipe (B) Pressure difference between two points in a pipe (C) Total pressure of liquid flowing in a pipe (D) Discharge through a pipe

Last Answer : Answer: Option A

Description : Pressure is measured with the help of A. Manometer. C) Thermocouple. B. Ammeter. D) Orifice plate.

Last Answer : manometer

Description : Root pressure is measured by (1) Barometer (2) Atmometer (3) Manometer (4) Auxanometer

Last Answer : Auxanometer

Description : What pressure measuring device consists of a coiled hollow tube that tends to straighten out when the tube is subjected to an internal pressure?  A. Aneroid  B. Manometer  C. Bourdon pressure gage  D. Barometer

Last Answer : Bourdon pressure gage

Description : Which of the following may be termed as a variable orifice flow-meter? (A) Rotameter (B) Pitot tube (C) V-notch (D) All (A), (B) and (C)

Last Answer : (A) Rotameter

Description : Which is not a variable head meter? (A) Venturimeter (B) Pitot tube (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : Bernoulli’s equation does not apply to the functioning of a/an (A) Venturimeter (B) Orificemeter (C) pitot tube (D) None of these

Last Answer : (D) None of these

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Which of the following is used for very accurate measurement of flow of gas at low velocity? (A) Pitot tube (B) Rotameter (C) Segmental orificemeter (D) Hot wire anemometer

Last Answer : (D) Hot wire anemometer

Description : The best instrument for measuring the velocity of a stream flow is (A) Pitot tube (B) Price's current meter (C) Surface float (D) Sub-surface float

Last Answer : Answer: Option B

Description : Bernoulli's equation is applied to (A) Venturimeter (B) Orifice meter (C) Pitot tube (D) All of these

Last Answer : Answer: Option D

Description : Which of the following instrument can be used for measuring speed of a submarine moving in deep sea? (A) Venturimeter (B) Orifice plate (C) Hot wire anemometer (D) Pitot tube

Last Answer : Answer: Option D

Description : Which of the following instrument can be used for measuring speed of an aeroplane? (A) Venturimeter (B) Orifice plate (C) Pitot tube (D) Rotameter

Last Answer : Answer: Option C

Description : Explain the working of a Pitot tube. 

Last Answer : The pitot tube measures the velocity at point in the conduct. If quantity rate measurement is desired, it must be calculated from the ratio of average velocity to the velocity at the point of measurement. ... will be a measure of the impact pressure and therefore of the velocity of the stream oil.  

Description : Explain with reason through which side of shell and tube heat exchanges, the following liquids are directed. (i) viscous liquid (ii) high pressure liquid (iii) corrosive liquid

Last Answer : Viscous liquid : Viscous liquid is passed through shell side Reason: because of the presence of baffles in the shell induce turbulence and hence increases heat transfer rate. High pressure liquid: High ... To avoid expensive alloy shells (in order to save the cost of expensive material for shell).

Description : How will you calibrate an absolute pressure transmitter using vacuum manometer. Range 0-400mm abs ?

Last Answer : The procedure for calibration is as follows : Connect air supply to the transmitter. Connect a test gauge of 0-1.4 Kg/cm2 to the output. Connect Vacuum pump with tee off to the manometer. Apply 760 ... nearest ) and adjust zero. Apply 360 mm Vacuum adjust span. ( 760 - 360 = 400 mm abs. )

Description : The suitable evaporator for concentration of foaming liquids is a __________ evaporator. (A) Long tube (B) Short tube (C) Vacuum (D) Falling film

Last Answer : (A) Long tube

Description : Viscous & heat sensitive liquids are concentrated in __________ evaporators. (A) Open pan (B) Long tube (C) Agitated film (D) None of these

Last Answer : (C) Agitated film

Description : Bed pressure drop in an air fluidised bed of catalyst particles (ρp = 200 kg/m3, Dp = 0.05 cm) of 60 cm bed depth and bed porosity of 0.5 expressed in cm of water (manometer) is (A) 90 (B) 60 (C) 45 (D) 30

Last Answer : (B) 60

Description : Differential manometer measures the (A) Atmospheric pressure (B) Sub-atmospheric pressure (C) Pressure difference between two points (D) None of these

Last Answer : (C) Pressure difference between two points

Description : 2. Differential manometer measures the (A) Absolute pressure (B) Gauge pressure (C) Pressure difference (D) Pressure gradien

Last Answer : (C) Pressure difference