Which is not a variable head meter?
(A) Venturimeter
(B) Pitot tube
(C) Rotameter
(D) None of these

1 Answer

Answer :

(C) Rotameter

Related questions

Description : The pressure head of a flow meter remains constant for (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Which of the following may be termed as a variable orifice flow-meter? (A) Rotameter (B) Pitot tube (C) V-notch (D) All (A), (B) and (C)

Last Answer : (A) Rotameter

Description : Water flow rate in a pipe of 3.5 metres diameter can be most economically and conveniently measured by a/an (A) Pitot tube (B) Venturimeter (C) Orificemeter (D) Rotameter

Last Answer : (A) Pitot tube

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : In a/an __________, the flow rate of fluids is obtained by measuring the difference between the impact and the static pressure. (A) Rotameter (B) Pitot tube (C) Venturimeter (D) Flow nozzle

Last Answer : (B) Pitot tube

Description : Which of the following instrument can be used for measuring speed of an aeroplane? (A) Venturimeter (B) Orifice plate (C) Pitot tube (D) Rotameter

Last Answer : Answer: Option C

Description : Flow of water in a pipe about 3 metres in diameter can be measured by (A) Orifice plate (B) Venturimeter (C) Rotameter (D) Pitot tube

Last Answer : Answer: Option D

Description : Bernoulli's equation is applied to (A) Venturimeter (B) Orifice meter (C) Pitot tube (D) All of these

Last Answer : Answer: Option D

Description : Flow rate of high velocity flue gas discharged through a stack to the atmosphere can be most conveniently measured by a (A) Pitot tube (B) Manometer (C) Rotameter (D) None of these

Last Answer : (A) Pitot tube

Description : Which of the following is used for very accurate measurement of flow of gas at low velocity? (A) Pitot tube (B) Rotameter (C) Segmental orificemeter (D) Hot wire anemometer

Last Answer : (D) Hot wire anemometer

Description : Speed of a submarine in deep sea & that of an aeroplane is measured by a/an (A) Pitot tube (B) Hot wire anemometer (C) Rotameter (D) Stroboscope

Last Answer : (A) Pitot tube

Description : Which of the following flow measuring devices is an area meter? (A) Venturimeter (B) Orificemeter (C) Anemometer (D) Rotameter

Last Answer : (D) Rotameter

Description : __________ is used for measuring the static pressure exerted on the wall by a fluid flowing parallel to the wall in a pipeline. (A) Venturimeter (B) Pressure gauge (C) Pitot tube (D) Orificemeter

Last Answer : (C) Pitot tube

Description : Bernoulli’s equation does not apply to the functioning of a/an (A) Venturimeter (B) Orificemeter (C) pitot tube (D) None of these

Last Answer : (D) None of these

Description : Which of the following instrument can be used for measuring speed of a submarine moving in deep sea? (A) Venturimeter (B) Orifice plate (C) Hot wire anemometer (D) Pitot tube

Last Answer : Answer: Option D

Description : Which of the following statement is wrong? (A) A flow whose streamline is represented by a curve is called two dimensional flow. (B) The total energy of a liquid particle is the sum of potential energy, ... (D) A pitot tube is used to measure the velocity of flow at the required point in a pipe.

Last Answer : Answer: Option C

Description : Flow measurement in an open channel is done by a/an (A) Venturimeter (B) Orificemeter (C) Weir (D) Rotameter

Last Answer : (C) Weir

Description : . It is possible to integrate an automatic flow controller to a (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : Out of the following flow measuring devices, which one incurs themaximum installation cost as well as pressure loss? (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) Orificemeter

Last Answer : (B) Venturimeter

Description : Which is the most efficient and best for measuring very small flow rate of gases? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Flow nozzle

Last Answer : (C) Rotameter

Description : The best instrument for measuring the velocity of a stream flow is (A) Pitot tube (B) Price's current meter (C) Surface float (D) Sub-surface float

Last Answer : Answer: Option B

Description : Air velocity in ducts can be measured by using and manometer a) Orifice meter b) Borden gauge c) Pitot tube d) Anemometer

Last Answer : Pitot tube

Description : . A Rotameter works on the principle of __________ pressure drop. (A) Constant (B) Variable (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (A) Constant

Description : In area meter (e.g., Rotameter), with increase in the fluid flow rate, the (A) Pressure drop increases linearly (B) Pressure drop is almost constant (C) Area through which fluid flows does not vary (D) None of these

Last Answer : (B) Pressure drop is almost constant

Description : The simple Pitot tube measures the __________ pressure. (A) static (B) Dynamic (C) Total (D) None of these

Last Answer : (C) Total

Description : The simple Pitot tube does not measure the (A) Static pressure (B) Dynamic pressure (C) Velocity at the stagnation point (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Small pressure differences in liquids is measured using a/an (A) U-tube manometer (B) Inclined tube manometer (C) Pitot tube (D) None of these

Last Answer : (B) Inclined tube manometer

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : The Prandtl Pitot tube measures the (A) Velocity at a point in the flow (B) Pressure at a point (C) Average flow velocity (D) Pressure difference in pipe flow

Last Answer : (A) Velocity at a point in the flow

Description : The pitot static tube does not measure the __________ pressure. (A) Static (B) Total (C) Difference in static & dynamic (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : A Pitot tube indicates 5 cm of water (manometer) when it is being used for measuring velocity of air. The velocity of air in m/sec is (A) 5 (B) 14.1 (C) 56.22 (D) 28.2

Last Answer : (D) 28.2

Description : the fluid flow rate increases, the float of the Rotameter (A) Rises in the tube (B) Rotates at higher speed (C) Rotates at lower speed (D) Drops down in the tube

Last Answer : Option A

Description : Select the wrong statement pertaining to flow of an incompressible fluid through a Venturimeter. (A) For frictionless flow, the fluid pressure entering the venturi meter will be exactly equal ... than an orificemeter (D) Venturimeter incurs less power loss compared to an equivalent orificemeter

Last Answer : (C) Venturimeter occupies less space than an orificemeter

Description : Sele(A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement. (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement

Description : Select the correct statement. (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter

Description : Related to ultrasonic flow meter: (i) Give any two types of it. (ii) Write any two specifications. (iii) Write two advantages over rotameter. 

Last Answer : (i) Two types of ultrasonic flow meter:  ➢ Transit time flow meters (time differences) ➢ Doppler type. (ii) Write any two specifications: - 1. Accuracy 2. Linearity 3. Repeatability 4. ... for bidirectional flow 8. Excellent dynamic response 9. Good accuracy +-2% 10. o/p is electrical

Description : Pitot tube is used for measurement of (A) Pressure (B) Flow (C) Velocity (D) Discharge

Last Answer : Answer: Option C

Description : A pitot tube is used to measure the (A) Velocity of flow at the required point in a pipe (B) Pressure difference between two points in a pipe (C) Total pressure of liquid flowing in a pipe (D) Discharge through a pipe

Last Answer : Answer: Option A

Description : What instrument is used to measure atmospheric pressure?  A. Pitot tube  B. Wind vane  C. Barometer  D. Manometer

Last Answer : Barometer

Description : Which of the following is NOT an instrument used to measure pressure?  A. Bourdon tube  B. Pitot tube  C. Aneroid  D. Manometer

Last Answer : Pitot tube

Description : Explain the working of a Pitot tube. 

Last Answer : The pitot tube measures the velocity at point in the conduct. If quantity rate measurement is desired, it must be calculated from the ratio of average velocity to the velocity at the point of measurement. ... will be a measure of the impact pressure and therefore of the velocity of the stream oil.  

Description : Vane anemometer (A) Is an area meter (B) Is a variable head meter (C) Rotates an element at a speed determined by the velocity of the fluid inwhich the meter is immersed (D) None of these

Last Answer : (C) Rotates an element at a speed determined by the velocity of the fluid inwhich the meter is immersed

Description : In case of Venturimeter, friction losses are about __________ percent of maximum velocity head. (A) 2 (B) 8 (C) 12 (D) 20

Last Answer : (A) 2

Description : A Venturimeter measures the (A) Velocity head (B) Pressure (C) Point velocity (D) None of these

Last Answer : (D) None of these

Description : For a given fluid flow rate, which of the following incurs maximum head loss? (A) Orificemeter (B) Venturimeter (C) Flow nozzle (D) All of them incur the same head loss

Last Answer : (A) Orificemeter

Description : Compare variable head flow meter with variable area flow meter.

Last Answer : Parameter Variable head flowmeter Variable area flowmeter Working principle Restriction or obstacle is placed in the path of flow to create a differential Pressure. The pressure ... viscous fluid slurries and dirty fluids. In laboratories and testing and production lines.

Description : Open channel liquid flow is most conveniently measured by a (A) Hot wire anemometer (B) Notch (C) Rotameter (D) Segmental orifice

Last Answer : (B) Notch

Description : In case of a Rotameter, the density of the float material is __________ that of the liquid it replaces. (A) More than (B) Less than (C) Equal to (D) Either (A) or (B)

Last Answer : (A) More than

Description : A Rotameter through which air at room temperature and atmospheric pressure is flowing gives a certain reading for a flow rate of 100 cc/sec. If helium (molecular weight 4) is used and Rotameter shows the same reading, the flow rate (cc/sec) is (A) 26 (B) 42 (C) 269 (D) 325

Last Answer : (C) 269

Description : The range of a particular Rotameter can be increased by (A) Use of floats of different densities (B) No means (C) Increasing the diameter of the float (D) Decreasing the diameter of the float

Last Answer : (A) Use of floats of different densities