Which of the following is used for very accurate measurement of flow
of gas at low velocity?
(A) Pitot tube
(B) Rotameter
(C) Segmental orificemeter
(D) Hot wire anemometer

1 Answer

Answer :

(D) Hot wire anemometer

Related questions

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Open channel liquid flow is most conveniently measured by a (A) Hot wire anemometer (B) Notch (C) Rotameter (D) Segmental orifice

Last Answer : (B) Notch

Description : Speed of a submarine in deep sea & that of an aeroplane is measured by a/an (A) Pitot tube (B) Hot wire anemometer (C) Rotameter (D) Stroboscope

Last Answer : (A) Pitot tube

Description : Water flow rate in a pipe of 3.5 metres diameter can be most economically and conveniently measured by a/an (A) Pitot tube (B) Venturimeter (C) Orificemeter (D) Rotameter

Last Answer : (A) Pitot tube

Description : The pressure head of a flow meter remains constant for (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Which of the following flow measuring devices is an area meter? (A) Venturimeter (B) Orificemeter (C) Anemometer (D) Rotameter

Last Answer : (D) Rotameter

Description : Flow rate of high velocity flue gas discharged through a stack to the atmosphere can be most conveniently measured by a (A) Pitot tube (B) Manometer (C) Rotameter (D) None of these

Last Answer : (A) Pitot tube

Description : Which of the following instrument can be used for measuring speed of a submarine moving in deep sea? (A) Venturimeter (B) Orifice plate (C) Hot wire anemometer (D) Pitot tube

Last Answer : Answer: Option D

Description : Flow measurement in an open channel is done by a/an (A) Venturimeter (B) Orificemeter (C) Weir (D) Rotameter

Last Answer : (C) Weir

Description : In hot wire anemometer used for gas flow measurement, the wire is normally made of (A) Copper (B) Platinum (C) Constantan (D) Chromium

Last Answer : (B) Platinum

Description : Which of the following may be termed as a variable orifice flow-meter? (A) Rotameter (B) Pitot tube (C) V-notch (D) All (A), (B) and (C)

Last Answer : (A) Rotameter

Description : In a/an __________, the flow rate of fluids is obtained by measuring the difference between the impact and the static pressure. (A) Rotameter (B) Pitot tube (C) Venturimeter (D) Flow nozzle

Last Answer : (B) Pitot tube

Description : Air velocity in ducts can be measured by using and manometer a) Orifice meter b) Borden gauge c) Pitot tube d) Anemometer

Last Answer : Pitot tube

Description : Flow of water in a pipe about 3 metres in diameter can be measured by (A) Orifice plate (B) Venturimeter (C) Rotameter (D) Pitot tube

Last Answer : Answer: Option D

Description : Which is the most efficient and best for measuring very small flow rate of gases? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Flow nozzle

Last Answer : (C) Rotameter

Description : Pitot tube is used for measurement of (A) Pressure (B) Flow (C) Velocity (D) Discharge

Last Answer : Answer: Option C

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : __________ is used for measuring the static pressure exerted on the wall by a fluid flowing parallel to the wall in a pipeline. (A) Venturimeter (B) Pressure gauge (C) Pitot tube (D) Orificemeter

Last Answer : (C) Pitot tube

Description : Bernoulli’s equation does not apply to the functioning of a/an (A) Venturimeter (B) Orificemeter (C) pitot tube (D) None of these

Last Answer : (D) None of these

Description : Which is not a variable head meter? (A) Venturimeter (B) Pitot tube (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : The most serious disadvantage of an orificemeter is that (A) It is not very accurate (B) It is very costly (C) Most of the pressure drop is not recoverable (D) It is not suitable for measuring gas flow

Last Answer : (C) Most of the pressure drop is not recoverable

Description : Out of the following flow measuring devices, which one incurs themaximum installation cost as well as pressure loss? (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) Orificemeter

Last Answer : (B) Venturimeter

Description : Which of the following instrument can be used for measuring speed of an aeroplane? (A) Venturimeter (B) Orifice plate (C) Pitot tube (D) Rotameter

Last Answer : Answer: Option C

Description : Venturimeters, orificemeters and nozzles are used to measure the fluid discharge from a pipeline. The average fluid velocity in a pipeline can be measured by a/an (A) Weir (B) Hot wire anemometer (C) Cup and vane anemometer (D) None of these

Last Answer : (B) Hot wire anemometer

Description : Hot wire anemometer is used to measure the (A) Velocity of liquids (B) Temperature of liquids (C) Velocity of gases (D) Pressure of liquids

Last Answer : (C) Velocity of gases

Description : The Prandtl Pitot tube measures the (A) Velocity at a point in the flow (B) Pressure at a point (C) Average flow velocity (D) Pressure difference in pipe flow

Last Answer : (A) Velocity at a point in the flow

Description : The best instrument for measuring the velocity of a stream flow is (A) Pitot tube (B) Price's current meter (C) Surface float (D) Sub-surface float

Last Answer : Answer: Option B

Description : Which of the following statement is wrong? (A) A flow whose streamline is represented by a curve is called two dimensional flow. (B) The total energy of a liquid particle is the sum of potential energy, ... (D) A pitot tube is used to measure the velocity of flow at the required point in a pipe.

Last Answer : Answer: Option C

Description : A pitot tube is used to measure the (A) Velocity of flow at the required point in a pipe (B) Pressure difference between two points in a pipe (C) Total pressure of liquid flowing in a pipe (D) Discharge through a pipe

Last Answer : Answer: Option A

Description : Which type of flow is measured by hot wire anemometer and describe its working principle with suitable diagram. 

Last Answer : Heat transfer flowmeters this type of flowmeter measures the rise in temperature of the fluid after a known amount of heat has been added to it. Its theory is based upon the specific heat equation ... a supply so as to maintain the wire temperature constant, when the amount of heat transfer varies

Description : Hot wire anemometer is used to measure (A) Pressure in gases (B) Liquid discharge (C) Pressure in liquids (D) Gas velocities

Last Answer : Answer: Option D

Description : The simple Pitot tube does not measure the (A) Static pressure (B) Dynamic pressure (C) Velocity at the stagnation point (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : A Pitot tube indicates 5 cm of water (manometer) when it is being used for measuring velocity of air. The velocity of air in m/sec is (A) 5 (B) 14.1 (C) 56.22 (D) 28.2

Last Answer : (D) 28.2

Description : The resistance wire used in a hot wire anemometer for conducting electrical current is made of (A) Copper (B) Tungsten (C) Chromium (D) Aluminium

Last Answer : (B) Tungsten

Description : Vena-contracta formed during flow of a liquid through an orificemeter has (A) Minimum liquid cross-section (B) More diameter compared to orifice diameter (C) Minimum velocity of fluid stream (D) None of these

Last Answer : (A) Minimum liquid cross-section

Description : the fluid flow rate increases, the float of the Rotameter (A) Rises in the tube (B) Rotates at higher speed (C) Rotates at lower speed (D) Drops down in the tube

Last Answer : Option A

Description : Explain working of 'hot wire anemometer with the help of diagram. 

Last Answer : Diagram : Working: The hot-wire anemometer is a fine resistance wire heated by a current passing through it. If a cooler fluid flows past the wire, heat is removed from it by the ... and responsive to high-frequency change in flow rate. One of its main application is aerodynamic research.

Description : Rotameter is a device used to measure (A) Absolute pressure (B) Velocity of fluid (C) Flow (D) Rotation

Last Answer : Answer: Option C

Description : Accurate measurement of very low resistances is possible with (A) Megger (B) Wheatstone Bridge (C) Kelvin’s Double Bridge (D) Wagner’s Earthing Device

Last Answer : Accurate measurement of very low resistances is possible with Kelvin’s Double Bridge

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : The simple Pitot tube measures the __________ pressure. (A) static (B) Dynamic (C) Total (D) None of these

Last Answer : (C) Total

Description : Small pressure differences in liquids is measured using a/an (A) U-tube manometer (B) Inclined tube manometer (C) Pitot tube (D) None of these

Last Answer : (B) Inclined tube manometer

Description : The pitot static tube does not measure the __________ pressure. (A) Static (B) Total (C) Difference in static & dynamic (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Venturimeter and orificemeter measures the __________ of the fluid. (A) Pressure (B) Maximum velocity (C) Average velocity (D) Point velocity

Last Answer : (C) Average velocity

Description : Select the wrong statement pertaining to flow of an incompressible fluid through a Venturimeter. (A) For frictionless flow, the fluid pressure entering the venturi meter will be exactly equal ... than an orificemeter (D) Venturimeter incurs less power loss compared to an equivalent orificemeter

Last Answer : (C) Venturimeter occupies less space than an orificemeter

Description : A mercury (specific gravity = 13.6) manometer connected across an orificemeter fitted in a pipe shows a manometer reading of 2 cms. If the manometer liquid is changed to carbon tetrachloride (specific gravity = 1.6), then ... new manometer reading will be __________ cms. (A) 17 (B) 42 (C) 84 (D) 1.8

Last Answer : __________ cms. (A) 17

Description : For the same flow rate of a fluid, the pressure drop is the least for (A) Venturimeter (B) Orificemeter (C) Flow-nozzle (D) Δp is same for all

Last Answer : (A) Venturimeter

Description : For a given fluid flow rate, which of the following incurs maximum head loss? (A) Orificemeter (B) Venturimeter (C) Flow nozzle (D) All of them incur the same head loss

Last Answer : (A) Orificemeter

Description : Bernoulli's equation is applied to (A) Venturimeter (B) Orifice meter (C) Pitot tube (D) All of these

Last Answer : Answer: Option D