In a/an __________, the flow rate of fluids is obtained by measuring the
difference between the impact and the static pressure.
(A) Rotameter
(B) Pitot tube
(C) Venturimeter
(D) Flow nozzle

1 Answer

Answer :

(B) Pitot tube

Related questions

Description : Water flow rate in a pipe of 3.5 metres diameter can be most economically and conveniently measured by a/an (A) Pitot tube (B) Venturimeter (C) Orificemeter (D) Rotameter

Last Answer : (A) Pitot tube

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : __________ is used for measuring the static pressure exerted on the wall by a fluid flowing parallel to the wall in a pipeline. (A) Venturimeter (B) Pressure gauge (C) Pitot tube (D) Orificemeter

Last Answer : (C) Pitot tube

Description : Which is the most efficient and best for measuring very small flow rate of gases? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Flow nozzle

Last Answer : (C) Rotameter

Description : The pressure head of a flow meter remains constant for (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Out of the following flow measuring devices, which one incurs themaximum installation cost as well as pressure loss? (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) Orificemeter

Last Answer : (B) Venturimeter

Description : Which of the following instrument can be used for measuring speed of an aeroplane? (A) Venturimeter (B) Orifice plate (C) Pitot tube (D) Rotameter

Last Answer : Answer: Option C

Description : Flow of water in a pipe about 3 metres in diameter can be measured by (A) Orifice plate (B) Venturimeter (C) Rotameter (D) Pitot tube

Last Answer : Answer: Option D

Description : Which is not a variable head meter? (A) Venturimeter (B) Pitot tube (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : . It is possible to integrate an automatic flow controller to a (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : Flow rate of high velocity flue gas discharged through a stack to the atmosphere can be most conveniently measured by a (A) Pitot tube (B) Manometer (C) Rotameter (D) None of these

Last Answer : (A) Pitot tube

Description : Which of the following instrument can be used for measuring speed of a submarine moving in deep sea? (A) Venturimeter (B) Orifice plate (C) Hot wire anemometer (D) Pitot tube

Last Answer : Answer: Option D

Description : Which of the following flow measuring devices is an area meter? (A) Venturimeter (B) Orificemeter (C) Anemometer (D) Rotameter

Last Answer : (D) Rotameter

Description : Which of the following may be termed as a variable orifice flow-meter? (A) Rotameter (B) Pitot tube (C) V-notch (D) All (A), (B) and (C)

Last Answer : (A) Rotameter

Description : Which of the following is used for very accurate measurement of flow of gas at low velocity? (A) Pitot tube (B) Rotameter (C) Segmental orificemeter (D) Hot wire anemometer

Last Answer : (D) Hot wire anemometer

Description : Which of the following statement is wrong? (A) A flow whose streamline is represented by a curve is called two dimensional flow. (B) The total energy of a liquid particle is the sum of potential energy, ... (D) A pitot tube is used to measure the velocity of flow at the required point in a pipe.

Last Answer : Answer: Option C

Description : Sele(A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement. (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement

Description : Select the correct statement. (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter

Description : The pitot static tube does not measure the __________ pressure. (A) Static (B) Total (C) Difference in static & dynamic (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : For the same flow rate of a fluid, the pressure drop is the least for (A) Venturimeter (B) Orificemeter (C) Flow-nozzle (D) Δp is same for all

Last Answer : (A) Venturimeter

Description : Speed of a submarine in deep sea & that of an aeroplane is measured by a/an (A) Pitot tube (B) Hot wire anemometer (C) Rotameter (D) Stroboscope

Last Answer : (A) Pitot tube

Description : Venturimeter is used to measure the flow rate of fluids in pipes, when the pipe is in __________ position. (A) Horizontal (B) Vertical (C) Inclined (D) Any

Last Answer : (D) Any

Description : The simple Pitot tube measures the __________ pressure. (A) static (B) Dynamic (C) Total (D) None of these

Last Answer : (C) Total

Description : Bernoulli’s equation does not apply to the functioning of a/an (A) Venturimeter (B) Orificemeter (C) pitot tube (D) None of these

Last Answer : (D) None of these

Description : For a given fluid flow rate, which of the following incurs maximum head loss? (A) Orificemeter (B) Venturimeter (C) Flow nozzle (D) All of them incur the same head loss

Last Answer : (A) Orificemeter

Description : Bernoulli's equation is applied to (A) Venturimeter (B) Orifice meter (C) Pitot tube (D) All of these

Last Answer : Answer: Option D

Description : Flow measurement in an open channel is done by a/an (A) Venturimeter (B) Orificemeter (C) Weir (D) Rotameter

Last Answer : (C) Weir

Description : The best instrument for measuring the velocity of a stream flow is (A) Pitot tube (B) Price's current meter (C) Surface float (D) Sub-surface float

Last Answer : Answer: Option B

Description : The simple Pitot tube does not measure the (A) Static pressure (B) Dynamic pressure (C) Velocity at the stagnation point (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The energy loss in flow through Venturimeter is less than that through flow nozzle, because in case of a flow nozzle, the (A) Length is shorter (B) Throat diameter is more (C) Sudden expansion of flow in the downstream occurs (D) Distance between the throat and the inlet is more

Last Answer : (C) Sudden expansion of flow in the downstream occurs

Description : The Prandtl Pitot tube measures the (A) Velocity at a point in the flow (B) Pressure at a point (C) Average flow velocity (D) Pressure difference in pipe flow

Last Answer : (A) Velocity at a point in the flow

Description : A Pitot tube indicates 5 cm of water (manometer) when it is being used for measuring velocity of air. The velocity of air in m/sec is (A) 5 (B) 14.1 (C) 56.22 (D) 28.2

Last Answer : (D) 28.2

Description : Which of the following instruments is used to measure flow on the application of Bernoulli's theorem? (A) Venturimeter (B) Orifice plate (C) Nozzle (D) All of the above

Last Answer : Answer: Option D

Description : A pitot tube is used to measure the (A) Velocity of flow at the required point in a pipe (B) Pressure difference between two points in a pipe (C) Total pressure of liquid flowing in a pipe (D) Discharge through a pipe

Last Answer : Answer: Option A

Description : the fluid flow rate increases, the float of the Rotameter (A) Rises in the tube (B) Rotates at higher speed (C) Rotates at lower speed (D) Drops down in the tube

Last Answer : Option A

Description : A differential pressure cell is used for (A) Measuring small pressure difference in gases (B) Measuring small pressure difference in liquids (C) Remote recording of pressure difference (D) Measuring the difference of the impact & the static pressure

Last Answer : (C) Remote recording of pressure difference

Description : Pitot tube is used for measurement of (A) Pressure (B) Flow (C) Velocity (D) Discharge

Last Answer : Answer: Option C

Description : Pick out the wrong statement. (A) The controlling resistance in case of heating of air by condensing steam is in the air film (B) The log mean temperature difference (LMTD) for ... a pure fluid at a given pressure from liquid to vapor or vice-versa occurs at saturation temperature

Last Answer : (C) In case of a 1 - 2 shell and tube heat exchanger, the LMTD correction factor value increases sharply, when a temperature cross occurs

Description : A Rotameter through which air at room temperature and atmospheric pressure is flowing gives a certain reading for a flow rate of 100 cc/sec. If helium (molecular weight 4) is used and Rotameter shows the same reading, the flow rate (cc/sec) is (A) 26 (B) 42 (C) 269 (D) 325

Last Answer : (C) 269

Description : In area meter (e.g., Rotameter), with increase in the fluid flow rate, the (A) Pressure drop increases linearly (B) Pressure drop is almost constant (C) Area through which fluid flows does not vary (D) None of these

Last Answer : (B) Pressure drop is almost constant

Description : For measuring flow by a Venturimeter, if should be installed in (A) Vertical line (B) Horizontal line (C) Inclined line with flow downward (D) In any direction and in any location

Last Answer : Answer: Option D

Description : Which of the following instruments require inputs of both pitot and static pressure? a. Airspeed indicator, machmeter and vertical speed indicator b. Airspeed indicator, vertical speed indicator, altimeter c. Airspeed indicator only d. Airspeed indicator and machmeter

Last Answer : d. Airspeed indicator and machmeter

Description : Which of the following instruments require inputs of both pitot and static pressure? a. Airspeed indicator, machmeter and vertical speed indicator b. Airspeed indicator, vertical speed indicator, altimeter c. Airspeed indicator only d. Airspeed indicator and machmeter

Last Answer : d. Airspeed indicator and machmeter

Description : Small pressure differences in liquids is measured using a/an (A) U-tube manometer (B) Inclined tube manometer (C) Pitot tube (D) None of these

Last Answer : (B) Inclined tube manometer

Description : The effect of friction on the flow of steam through a nozzle is to decrease the __________ of steam. (A) Wetness (B) Mass flow rate (C) Both 'a' & 'b' (D) Neither 'a' nor 'b'

Last Answer : (C) Both 'a' & 'b'

Description : What instrument is used to measure atmospheric pressure?  A. Pitot tube  B. Wind vane  C. Barometer  D. Manometer

Last Answer : Barometer

Description : Which of the following is NOT an instrument used to measure pressure?  A. Bourdon tube  B. Pitot tube  C. Aneroid  D. Manometer

Last Answer : Pitot tube

Description : A Venturimeter cannot be used for the direct measurement of (A) Datum difference in the stretch of pipe-flow (B) Pressure difference in the flow through pipeline (C) Friction loss in pipe flow (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Drag force on the float of a Rotameter is (where Q = flow rate of the) (A) ∝ Q (B) ∝ √Q (C) ∝ Q2 (D) Constant