Water flow rate in a pipe of 3.5 metres diameter can be most
economically and conveniently measured by a/an
(A) Pitot tube
(B) Venturimeter
(C) Orificemeter
(D) Rotameter

1 Answer

Answer :

(A) Pitot tube

Related questions

Description : Flow of water in a pipe about 3 metres in diameter can be measured by (A) Orifice plate (B) Venturimeter (C) Rotameter (D) Pitot tube

Last Answer : Answer: Option D

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : The pressure head of a flow meter remains constant for (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Flow rate of high velocity flue gas discharged through a stack to the atmosphere can be most conveniently measured by a (A) Pitot tube (B) Manometer (C) Rotameter (D) None of these

Last Answer : (A) Pitot tube

Description : In a/an __________, the flow rate of fluids is obtained by measuring the difference between the impact and the static pressure. (A) Rotameter (B) Pitot tube (C) Venturimeter (D) Flow nozzle

Last Answer : (B) Pitot tube

Description : Which of the following is used for very accurate measurement of flow of gas at low velocity? (A) Pitot tube (B) Rotameter (C) Segmental orificemeter (D) Hot wire anemometer

Last Answer : (D) Hot wire anemometer

Description : Which is the most efficient and best for measuring very small flow rate of gases? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Flow nozzle

Last Answer : (C) Rotameter

Description : __________ is used for measuring the static pressure exerted on the wall by a fluid flowing parallel to the wall in a pipeline. (A) Venturimeter (B) Pressure gauge (C) Pitot tube (D) Orificemeter

Last Answer : (C) Pitot tube

Description : Bernoulli’s equation does not apply to the functioning of a/an (A) Venturimeter (B) Orificemeter (C) pitot tube (D) None of these

Last Answer : (D) None of these

Description : Which is not a variable head meter? (A) Venturimeter (B) Pitot tube (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : Flow measurement in an open channel is done by a/an (A) Venturimeter (B) Orificemeter (C) Weir (D) Rotameter

Last Answer : (C) Weir

Description : Out of the following flow measuring devices, which one incurs themaximum installation cost as well as pressure loss? (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) Orificemeter

Last Answer : (B) Venturimeter

Description : Which of the following flow measuring devices is an area meter? (A) Venturimeter (B) Orificemeter (C) Anemometer (D) Rotameter

Last Answer : (D) Rotameter

Description : Which of the following instrument can be used for measuring speed of an aeroplane? (A) Venturimeter (B) Orifice plate (C) Pitot tube (D) Rotameter

Last Answer : Answer: Option C

Description : Which of the following statement is wrong? (A) A flow whose streamline is represented by a curve is called two dimensional flow. (B) The total energy of a liquid particle is the sum of potential energy, ... (D) A pitot tube is used to measure the velocity of flow at the required point in a pipe.

Last Answer : Answer: Option C

Description : Speed of a submarine in deep sea & that of an aeroplane is measured by a/an (A) Pitot tube (B) Hot wire anemometer (C) Rotameter (D) Stroboscope

Last Answer : (A) Pitot tube

Description : Open channel liquid flow is most conveniently measured by a (A) Hot wire anemometer (B) Notch (C) Rotameter (D) Segmental orifice

Last Answer : (B) Notch

Description : Which of the following may be termed as a variable orifice flow-meter? (A) Rotameter (B) Pitot tube (C) V-notch (D) All (A), (B) and (C)

Last Answer : (A) Rotameter

Description : For the same flow rate of a fluid, the pressure drop is the least for (A) Venturimeter (B) Orificemeter (C) Flow-nozzle (D) Δp is same for all

Last Answer : (A) Venturimeter

Description : For a given fluid flow rate, which of the following incurs maximum head loss? (A) Orificemeter (B) Venturimeter (C) Flow nozzle (D) All of them incur the same head loss

Last Answer : (A) Orificemeter

Description : Select the wrong statement pertaining to flow of an incompressible fluid through a Venturimeter. (A) For frictionless flow, the fluid pressure entering the venturi meter will be exactly equal ... than an orificemeter (D) Venturimeter incurs less power loss compared to an equivalent orificemeter

Last Answer : (C) Venturimeter occupies less space than an orificemeter

Description : The Prandtl Pitot tube measures the (A) Velocity at a point in the flow (B) Pressure at a point (C) Average flow velocity (D) Pressure difference in pipe flow

Last Answer : (A) Velocity at a point in the flow

Description : Bernoulli's equation is applied to (A) Venturimeter (B) Orifice meter (C) Pitot tube (D) All of these

Last Answer : Answer: Option D

Description : Which of the following instrument can be used for measuring speed of a submarine moving in deep sea? (A) Venturimeter (B) Orifice plate (C) Hot wire anemometer (D) Pitot tube

Last Answer : Answer: Option D

Description : . It is possible to integrate an automatic flow controller to a (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : A pitot tube is used to measure the (A) Velocity of flow at the required point in a pipe (B) Pressure difference between two points in a pipe (C) Total pressure of liquid flowing in a pipe (D) Discharge through a pipe

Last Answer : Answer: Option A

Description : A mercury (specific gravity = 13.6) manometer connected across an orificemeter fitted in a pipe shows a manometer reading of 2 cms. If the manometer liquid is changed to carbon tetrachloride (specific gravity = 1.6), then ... new manometer reading will be __________ cms. (A) 17 (B) 42 (C) 84 (D) 1.8

Last Answer : __________ cms. (A) 17

Description : Very small pressure difference (< 5 mm water column) can be most conveniently measured by a/an __________ manometer. (A) U-tube water (B) U-tube mercury (C) Inclined tube mercury (D) Inclined tube water

Last Answer : (D) Inclined tube water

Description : Vena-contracta pressure tapping is at a distance __________ from the position of an orificemeter fitted in a pipe of internal diameter 'd' (A) d (B) 0.5 d (C) 2d (D) 4d

Last Answer : (B) 0.5 d

Description : Location of vena-contracta in an orificemeter does not depend upon the (A) Type of orifice (B) Density, viscosity & compressibility of the fluid (C) Ratio of pipe diameter to orifice diameter (D) Pipe roughness

Last Answer : (A) Type of orifice

Description : With increase in the ratio of orifice diameter to pipe diameter in case of an orificemeter, the overall pressure loss (A) Decreases (B) Increases (C) Remain constant (D) Increases linearly

Last Answer : (C) Remain constant

Description : Venturimeter and orificemeter measures the __________ of the fluid. (A) Pressure (B) Maximum velocity (C) Average velocity (D) Point velocity

Last Answer : (C) Average velocity

Description : Power loss in an orificemeter is __________ that in a Venturimeter. (A) Less than (B) Same as (C) More than (D) Data insufficient, cannot be predicted

Last Answer : (C) More than

Description : the fluid flow rate increases, the float of the Rotameter (A) Rises in the tube (B) Rotates at higher speed (C) Rotates at lower speed (D) Drops down in the tube

Last Answer : Option A

Description : Sele(A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement. (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement

Description : Select the correct statement. (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter

Description : Venturimeter is used to measure the flow rate of fluids in pipes, when the pipe is in __________ position. (A) Horizontal (B) Vertical (C) Inclined (D) Any

Last Answer : (D) Any

Description : Small pressure differences in liquids is measured using a/an (A) U-tube manometer (B) Inclined tube manometer (C) Pitot tube (D) None of these

Last Answer : (B) Inclined tube manometer

Description : A fluid is flowing inside the inner tube of a double pipe heat exchanger with diameter 'd'. For a fixed mass flow rate, the tube side heat transfer co￾efficient for turbulent flow conditions is proportional to (A) d 0.8 (B) d -0.2 (C) d -1 (D) d -1.8

Last Answer : (B) d -0.2

Description : Air velocity in ducts can be measured by using and manometer a) Orifice meter b) Borden gauge c) Pitot tube d) Anemometer

Last Answer : Pitot tube

Description : Vena-contracta formed during flow of a liquid through an orificemeter has (A) Minimum liquid cross-section (B) More diameter compared to orifice diameter (C) Minimum velocity of fluid stream (D) None of these

Last Answer : (A) Minimum liquid cross-section

Description : In order to avoid tendency of separation at throat in a Venturimeter, the ratio of the diameter at throat to the diameter of pipe should be (A) 1/16 to 1/8 (B) 1/8 to 1/4 (C) 1/4 to 1/3 (D) 1/3 to 1/2

Last Answer : Answer: Option D

Description : A Venturimeter cannot be used for the direct measurement of (A) Datum difference in the stretch of pipe-flow (B) Pressure difference in the flow through pipeline (C) Friction loss in pipe flow (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The best instrument for measuring the velocity of a stream flow is (A) Pitot tube (B) Price's current meter (C) Surface float (D) Sub-surface float

Last Answer : Answer: Option B

Description : Pitot tube is used for measurement of (A) Pressure (B) Flow (C) Velocity (D) Discharge

Last Answer : Answer: Option C

Description : The energy loss in flow through Venturimeter is less than that through flow nozzle, because in case of a flow nozzle, the (A) Length is shorter (B) Throat diameter is more (C) Sudden expansion of flow in the downstream occurs (D) Distance between the throat and the inlet is more

Last Answer : (C) Sudden expansion of flow in the downstream occurs

Description : The co-efficient of discharge of an orificemeter is a function of (A) Reynolds number at the orifice (B) Ratio of orifice dia to pipe dia (C) Both (A) and (B) (D) None of the above parameters, and has a constant value of 0.61

Last Answer : (C) Both (A) and (B)

Description : If Q is discharge is cubic metres per sec and D is the economical diameter of the pipe. According to Lea (A) D = 0.67 to 0.87 Q (B) D = 0.77 to 0.97 Q (C) D = 0.97 to 1.22 Q (D) D = 1.22 to 1.33 Q

Last Answer : (C) D = 0.97 to 1.22 Q

Description : For calculation of economical diameter D of a pipe in metres for a discharge Q to be pumped in  cumecs, Lea suggested the empirical formula  (A) D = 0.22 Q (B) D = 1.22 Q (C) D = 2.22 Q (D) D = 3.22 Q

Last Answer : (B) D = 1.22 Q