When incomplete combustion loss is high, the flue gas analysis shows
large amount of
(A) CO2
(B) CO
(C) O2
(D) C

1 Answer

Answer :

(B) CO

Related questions

Description : Incomplete combustion of fuel in the furnace is judged by high __________ of the flue gases. (A) CO content (B) Dew point (C) CO2 content (D) O2 content

Last Answer : (A) CO content

Description : Volumetric composition of flue gas analysed with the Orsat apparatus is : CO2 = 12%, O2 = 8%, CO = nil, N2 = 80%. This flue gas composition indicates that (A) Pure oxygen has been used for combustion ... very high (C) Excess air has been used for combustion (D) Hydrogen is not present in the fuel

Last Answer : (C) Excess air has been used for combustion

Description : To maximize the combustion efficiency, which of the following in the flue gas needs to be done? a) maximize O2 b) maximize CO2 c) minimize CO2 d) maximize CO

Last Answer : b) maximize CO2

Description : The sequence of absorption in flue gas analysis by Orsat's apparatus is respectively (A) CO2 , O2 , CO (B) CO, O2 , CO2 (C) CO2 , CO, O2

Last Answer : (A) CO2 , O2 , CO

Description : Efficiency of the combustion of a fuel is judged by the __________ the flue gas. (A) % of CO2 in (B) % of O2 in (C) Temperature of (D) Colour of

Last Answer : (B) % of O2 in

Description : If oxygen content in the flue gas rises too high, fuel is being wasted by (A) Incomplete combustion (B) Dry gas/stack gas loss (C) Moisture loss (D) None of these

Last Answer : (B) Dry gas/stack gas loss

Description : Which instrument is used to monitor O2, CO in flue gas? (EA) a) Combustion analyser b) Power analyser c) Pyrometer d) Fyrite

Last Answer : Combustion analyser

Description : instrument is used to monitor O2, CO in flue gas (EA) a) Combustion analyzer b) Power analyzer c) Pyrometer d) Fyrite

Last Answer : Combustion analyzer

Description : Which instrument is used to monitor O2, CO in flue gas? c)Combustion analyzer c) Pyrometer d)Power analyzer d) Fyrite

Last Answer : Combustion analyzer

Description : 115. Which instrument is used to monitor O2, CO in flue gas? a) Combustion analyzer c) Pyrometer b) Power analyzer d) Fyrite

Last Answer : Combustion analyzer

Description : Flue gas obtained on complete combustion of pure acetylene (a hydrocarbon fuel) will contain (A) CO (B) CO2 (C) H2O (D) Both (B) & (C)

Last Answer : (D) Both (B) & (C)

Description : During combustion of a gaseous fuel, the presence of a non-luminous flame is an indication of the (A) Incomplete combustion (B) Complete combustion (C) High oxygen in flue gas (D) None of these

Last Answer : (B) Complete combustion

Description : Incomplete combustion of a fuel is characterised by the high __________ in the flue gas. (A) Smoke (B) Temperature (C) Oxygen (D) Carbon monoxide

Last Answer : (D) Carbon monoxide

Description : Which of the following accounts for maximum energy loss in a boiler? (A) Flue gases (B) Ash content in the fuel (C) Incomplete combustion (D) Unburnt carbon in flue gases

Last Answer : (A) Flue gases

Description : A sample of natural gas containing 80% methane (CH4 ) and rest nitrogen (N2 ) is burnt with 20% excess air. With 80% of the combustibles producing CO2 and the remainder going to CO, the Orsat analysis in volume percent is (A) CO2 : 6 ... 96, N2 :72.06 (D) CO2 : 7.60, CO : 1.90, O2 : 4.75, N2 : 85.74

Last Answer : (B) CO2 : 7.42, CO : 1.86, O2 : 4.64, N2 :86.02

Description : The average molecular weight of a flue gas having the composition by volume as CO2 = 25%, O2 = 25%, N2 = 50% will be (A) 27.6 (B) 23 (C) 47.3 (D) 42.9

Last Answer : (B) 23

Description : In practical operation of any furnace, zero oxygen percentage or theoretical CO2 percentage in flue gas is rarely achieved, because of (A) Use of non-preheated combustion air (B) Use of pulverised solid ... of fuel & air and infiltration of air (D) Use of excessive positive draft in the furnace

Last Answer : (C) Imperfect mixing of fuel & air and infiltration of air

Description : A carbonaceous fuel (containing no H2 or hydrocarbons) is burnt and the resulting flue gas contains 21% CO2 . It means that (A) 21% excess air has been used for combustion (B) 21% excess oxygen has ... (C) Complete combustion of fuel has taken place (D) No excess air has been used for combustion

Last Answer : (C) Complete combustion of fuel has taken place

Description : __________ the exhaust gas is an indication of the incomplete combustion of fuel. (A) Low temperature of (B) High temperature of (C) High % of CO in (D) High % of CO2in

Last Answer : (C) High % of CO in

Description : Scaling of furnace stock is reduced by __________ in flue gas. (A) CO (B) H2 (C) High CO/CO2 (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Ostwald charts are meant for (A) Computing the excess/deficiency of combustion air (B) Calculation of flue gas temperature (C) Computation of flue gas analysis (D) None of these

Last Answer : (A) Computing the excess/deficiency of combustion air

Description : Orsat apparatus is meant for (A) Gravimetric analysis of flue gas (B) Finding out combustion efficiency (C) Direct determination of nitrogen in flue gas by absorbing it in ammoniacal cuprous chloride (D) None of these

Last Answer : (D) None of these

Description : Acid rains are produced by (a) excess NO2 and SO2 from burning fossil fuels (b) excess production of NH3 by industry and coal  gas (c) excess release of carbon monoxide by incomplete  combustion (d) excess formation of CO2 by combustion and  animal respiration.

Last Answer : (a) excess NO2 and SO2 from burning fossil fuels

Description : Acid rains are produced by (a) excess NO2 and SO2 from burning fossil fuels (b) excess production of NH3 by industry and coal gas (c) excess release of carbon monoxide by incomplete combustion (d) excess formation of CO2 by combustion and animal respiration.

Last Answer : (a) excess NO2 and SO2 from burning fossil fuels

Description : Pick out the wrong statement. (A) High concentration of oxygen in flue gas means high stack loss (B) Gaseous fuels require the least % excess air for complete combustion (C) The ratio of fixed carbon to ... coal is called its 'fuel ratio' (D) Calorific value of natural gas is more than that of LPG

Last Answer : (D) Calorific value of natural gas is more than that of LPG

Description : The main drawback of supplying more excess air in the combustion of fuel is the (A) Excessive power requirement of air blower (B) Enhanced sensible heat loss in the flue gas (C) Intermittent and uncontrolled combustion of the fuel (D) High exit flue gas temperature from the furnace

Last Answer : (B) Enhanced sensible heat loss in the flue gas

Description : In order to maintain an oxidising atmosphere in a furnace, it should have (A) More of excess air (B) Less of excess air (C) More of CO in flue gas (D) More of CO2 in flue gas

Last Answer : (A) More of excess air

Description : Presence of nitrogen in combustion air does not reduce the (A) Amount of heat liberated (B) Flame temperature (C) Flue gas temperature (D) Any of the above

Last Answer : (A) Amount of heat liberated

Description : Oxygen enrichment of combustion air does not result in increase of the (A) Flame temperature (B) Oxygen in the flue gas (C) Stack loss (D) Heat transfer rate in the furnace

Last Answer : (B) Oxygen in the flue gas

Description : Out of the following fuels used in a furnace exhausting flue gas at a temperature of 600°C, the percentage stack loss will be maximum in case ofcomplete combustion of (A) Furnace oil with air (B) Furnace oil with oxygen (C) Blast furnace gas with air (D) Blast furnace gas with oxygen

Last Answer : (C) Blast furnace gas with air

Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Combustion of fuel in a furnace with oxygen enriched air results in higher (A) Flue gas volume (B) Flame temperature (C) Fuel consumption (D) Stack loss

Last Answer : (B) Flame temperature

Description : The combustion reaction, C + O2 = CO2 , is (A) Exothermic (B) Endothermic (C) Autocatalytic

Last Answer : (A) Exothermic

Description : The combustion reaction, C + O2 = CO2 , is (A) Exothermic (B) Endothermic (C) Autocatalytic (D) None of these

Last Answer : (A) Exothermic

Description : Main constituents of purified Lurgi gas are (A) H2 , CmHn & CO2 (B) CO, H2 & CH4 (C) CO2 , O2 & CO (D) N2 , H2 & CO2

Last Answer : (B) CO, H2 & CH4

Description : L.D. converter gas (produced in steel plant) comprises mainly of (A) CO (upto 65%) & CO2 (B) CO2 & H2 (C) CO & O2 (D) CO2 & O2

Last Answer : (A) CO (upto 65%) & CO2

Description : Fuel combustion is never cent per cent efficient due to (A) Incomplete combustion (B) Dry gas/stack gas loss (C) Moisture loss (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Orsat apparatus (A) Gives flue gas analysis on dry basis (B) Determines N2 in flue gas indirectly (C) Can’t determine CO in flue gas, if it is < 0.2% (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Which among the following has the highest flue gas loss on combustion due to Hydrogen in the fuel? a) natural gas b) furnace oil c) coal d) light diesel oil

Last Answer : a) natural gas

Description : In a petrol engine, which of the following gas gets exhausted out without burning and without transformation? a. CO2 b. CO c. O2 d. N2

Last Answer : ANSWER d. N2

Description : Water gas is a mixture of (A) CO2 and O2 (B) O2 and H2 (C) H2, N2 and O2 (D) CO, N2 and H2.

Last Answer : CO, N2 and H2.

Description : Steam is intermittently admitted into the fuel bed during the production of producer gas to (A) Convert CO to CO2 (B) Increase the combustion rate (C) Increase the gas production rate (D) Minimise the chances of clinker formation

Last Answer : (D) Minimise the chances of clinker formation

Description : A liquid/gaseous fuel containing hydrocarbons and high amount of sulphur is burnt with 40% excess air. The flue gas still contains large amount of carbon monoxide. This may be due to the (A) Presence of large ... fuel (C) High sulphur content in the fuel (D) Lack of thorough mixing of fuel with air

Last Answer : (D) Lack of thorough mixing of fuel with air

Description : Higher efficiency in the combustion of solid fuel cannot be achieved by (A) Proper fuel preparation (B) Keeping the flue gas exhaust temperature very high (C) Adopting efficient-fuel firing technique & equipment (D) Supplying correct quantity of combustion air

Last Answer : (B) Keeping the flue gas exhaust temperature very high

Description : Too much of excess air in combustion results in high (A) Fuel consumption for the same heat load (B) Stack gas temperature (C) Percentage of oxygen in flue gases (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Advantages of fluidised bed combustion are (A) Reduced NOx formation in flue gas (B) Lower furnace operating temperature (C) High heat transfer rate (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Pick out the wrong statement. (A) A slight haze at the top of chimney indicates good combustion in the furnace (B) A bag filter incurs very small pressure drop and is very efficient for ... dust collection equipment for removal of submicronic dust particles present in flue gas (D) None of these

Last Answer : (B) A bag filter incurs very small pressure drop and is very efficient for removal of submicronic dust particles from flue gases at very high temperature

Description : Blood haemoglobin has high affinity for (a) CO2 (b) CO (c) O2 (d) H

Last Answer : Ans:(b)

Description : Photo chemical smog is a result-ant of the reaction among – (1) High concentration of NO2, O3, and CO in the evening (2) CO, CO2 and NO2 at low temperature (3) CO, O2 and peroxy acetyl nitrate in the presence of Sunlight (4) NO2, O3 and peroxy acetyl nitrate in the presence of Sunlight