Ostwald charts are meant for
(A) Computing the excess/deficiency of combustion air
(B) Calculation of flue gas temperature
(C) Computation of flue gas analysis
(D) None of these

1 Answer

Answer :

(A) Computing the excess/deficiency of combustion air

Related questions

Description : Too much of excess air in combustion results in high (A) Fuel consumption for the same heat load (B) Stack gas temperature (C) Percentage of oxygen in flue gases (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The main drawback of supplying more excess air in the combustion of fuel is the (A) Excessive power requirement of air blower (B) Enhanced sensible heat loss in the flue gas (C) Intermittent and uncontrolled combustion of the fuel (D) High exit flue gas temperature from the furnace

Last Answer : (B) Enhanced sensible heat loss in the flue gas

Description : Orsat apparatus is meant for (A) Gravimetric analysis of flue gas (B) Finding out combustion efficiency (C) Direct determination of nitrogen in flue gas by absorbing it in ammoniacal cuprous chloride (D) None of these

Last Answer : (D) None of these

Description : Pick out the wrong statement. (A) High concentration of oxygen in flue gas means high stack loss (B) Gaseous fuels require the least % excess air for complete combustion (C) The ratio of fixed carbon to ... coal is called its 'fuel ratio' (D) Calorific value of natural gas is more than that of LPG

Last Answer : (D) Calorific value of natural gas is more than that of LPG

Description : A carbonaceous fuel (containing no H2 or hydrocarbons) is burnt and the resulting flue gas contains 21% CO2 . It means that (A) 21% excess air has been used for combustion (B) 21% excess oxygen has ... (C) Complete combustion of fuel has taken place (D) No excess air has been used for combustion

Last Answer : (C) Complete combustion of fuel has taken place

Description : Oxygen content in a flue gas was found to be 4%. It implies that excess air used for combustion was around __________ percent. (A) 4 (B) 96 (C) 20 (D) 40

Last Answer : (C) 20

Description : Volumetric composition of flue gas analysed with the Orsat apparatus is : CO2 = 12%, O2 = 8%, CO = nil, N2 = 80%. This flue gas composition indicates that (A) Pure oxygen has been used for combustion ... very high (C) Excess air has been used for combustion (D) Hydrogen is not present in the fuel

Last Answer : (C) Excess air has been used for combustion

Description : When incomplete combustion loss is high, the flue gas analysis shows large amount of (A) CO2 (B) CO (C) O2 (D) C

Last Answer : (B) CO

Description : Pure carbon is completely burnt in oxygen. The flue gas analysis is 70%CO2 , 20%CO and 10%O2 . The percent excess oxygen used is (A) 20 (B) 12.5 (C) 0 (D) 10

Last Answer : (C) 0

Description : Oxygen enrichment of combustion air does not result in increase of the (A) Flame temperature (B) Oxygen in the flue gas (C) Stack loss (D) Heat transfer rate in the furnace

Last Answer : (B) Oxygen in the flue gas

Description : Out of the following fuels used in a furnace exhausting flue gas at a temperature of 600°C, the percentage stack loss will be maximum in case ofcomplete combustion of (A) Furnace oil with air (B) Furnace oil with oxygen (C) Blast furnace gas with air (D) Blast furnace gas with oxygen

Last Answer : (C) Blast furnace gas with air

Description : Combustion of fuel in a furnace with oxygen enriched air results in higher (A) Flue gas volume (B) Flame temperature (C) Fuel consumption (D) Stack loss

Last Answer : (B) Flame temperature

Description : Higher efficiency in the combustion of solid fuel cannot be achieved by (A) Proper fuel preparation (B) Keeping the flue gas exhaust temperature very high (C) Adopting efficient-fuel firing technique & equipment (D) Supplying correct quantity of combustion air

Last Answer : (B) Keeping the flue gas exhaust temperature very high

Description : Presence of nitrogen in combustion air does not reduce the (A) Amount of heat liberated (B) Flame temperature (C) Flue gas temperature (D) Any of the above

Last Answer : (A) Amount of heat liberated

Description : In practical operation of any furnace, zero oxygen percentage or theoretical CO2 percentage in flue gas is rarely achieved, because of (A) Use of non-preheated combustion air (B) Use of pulverised solid ... of fuel & air and infiltration of air (D) Use of excessive positive draft in the furnace

Last Answer : (C) Imperfect mixing of fuel & air and infiltration of air

Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Acid dew point temperature (ADT) of a flue gas produced by the combustion of a fuel containing 1% sulphur may be about __________ °C. (A) 80 (B) 130 (C) 180 (D) 250

Last Answer : (B) 130

Description : Efficiency of the combustion of a fuel is judged by the __________ the flue gas. (A) % of CO2 in (B) % of O2 in (C) Temperature of (D) Colour of

Last Answer : (B) % of O2 in

Description : Advantages of fluidised bed combustion are (A) Reduced NOx formation in flue gas (B) Lower furnace operating temperature (C) High heat transfer rate (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Incomplete combustion of a fuel is characterised by the high __________ in the flue gas. (A) Smoke (B) Temperature (C) Oxygen (D) Carbon monoxide

Last Answer : (D) Carbon monoxide

Description : Pick out the wrong statement. (A) A slight haze at the top of chimney indicates good combustion in the furnace (B) A bag filter incurs very small pressure drop and is very efficient for ... dust collection equipment for removal of submicronic dust particles present in flue gas (D) None of these

Last Answer : (B) A bag filter incurs very small pressure drop and is very efficient for removal of submicronic dust particles from flue gases at very high temperature

Description : In order to maintain an oxidising atmosphere in a furnace, it should have (A) More of excess air (B) Less of excess air (C) More of CO in flue gas (D) More of CO2 in flue gas

Last Answer : (A) More of excess air

Description : A liquid/gaseous fuel containing hydrocarbons and high amount of sulphur is burnt with 40% excess air. The flue gas still contains large amount of carbon monoxide. This may be due to the (A) Presence of large ... fuel (C) High sulphur content in the fuel (D) Lack of thorough mixing of fuel with air

Last Answer : (D) Lack of thorough mixing of fuel with air

Description : Economizer is provided to utilize the flue gas heat for ___ a) preheating the boiler feed water b) preheating the stock c) preheating the combustion air d) preheating fuel

Last Answer : preheating the boiler feed water

Description : Oxygen trim control strategy __ a. continuously measures the oxygen content in the flue gas b. adjusts the combustion air flow c. Continually tuning the air-fuel mixture. d. All of above

Last Answer : d. All of above

Description : measures oxygen and temperature of the flue gas. a) Fuel efficiency monitor. b) Combustion analyzer. c) Contact thermometer. d) Infrared thermometer.

Last Answer : Combustion analyzer

Description : If oxygen content in the flue gas rises too high, fuel is being wasted by (A) Incomplete combustion (B) Dry gas/stack gas loss (C) Moisture loss (D) None of these

Last Answer : (B) Dry gas/stack gas loss

Description : During combustion of a gaseous fuel, the presence of a non-luminous flame is an indication of the (A) Incomplete combustion (B) Complete combustion (C) High oxygen in flue gas (D) None of these

Last Answer : (B) Complete combustion

Description : Flue gas obtained on complete combustion of pure acetylene (a hydrocarbon fuel) will contain (A) CO (B) CO2 (C) H2O (D) Both (B) & (C)

Last Answer : (D) Both (B) & (C)

Description : High sulphur content in a fuel __________ of the flue gases. (A) Decreases the dew point (B) Increases the dew point (C) Reduces the combustion efficiency by limiting the permissible temperature reduction (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : Use of excess of combustion air in the combustion of fuels results in (A) Heat losses (B) Long flame (C) Condensation of water vapour from the fuel gas (D) None of these

Last Answer : (A) Heat losses

Description : Which of the following would require maximum amount of % excess air for complete combustion? (A) Coke oven gas (B) Furnace oil (C) Pulverised coal (D) Lump coal (fixed on chain grate)

Last Answer : (D) Lump coal (fixed on chain grate)

Description : Pick out the wrong statement. (A) Strongly caking coal should not be used in the Lurgi gasifier (B) Acetylene gas cannot be used for illumination purpose (C) Water gas is called blue gas ... is burnt (D) Gaseous fuels require less percentage of excess air for combustion as compared to liquid fuels

Last Answer : (B) Acetylene gas cannot be used for illumination purpose

Description : Combustion of pulverised coal as compared to that of lump coal (A) Develops a non-luminous flame (B) Develops a low temperature flame (C) Can be done with less excess air (D) Provides a lower rate of heat release

Last Answer : (C) Can be done with less excess ai

Description : Combustion of pulverised coal compared to the lumpy coal (A) Provides better control of furnace temperature (B) Facilitates combustion with lower excess air (C) Provides higher thermal efficiency & flame temperature (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Supply of excess air for complete combustion of fuel is necessitated to facilitate (A) Its thorough mixing with air (B) Attainment of chemical equilibrium (C) Attainment of high temperature (D) None of these

Last Answer : (A) Its thorough mixing with air

Description : The optimum percentage of excess air for combustion depends upon the__________ of the fuel. (A) Type (solid, liquid or gaseous) (B) Calorific value (C) Sulphur content (D) Ignition temperature

Last Answer : (A) Type (solid, liquid or gaseous)

Description : _______ is a type of computing that performs computation, storage and even applications as a service across a network. (1) Cloud Computing (2) Distributed Computing (3) Parallel Computing (4) Virtual Computing

Last Answer : Cloud Computing 

Description : A flue damper and a vent damper are two examples of _______ a. Combustion air positive shut off devices b. Combustion air negative shut off devices c. Both a. & b. d. None of the above

Last Answer : a. Combustion air positive shut off devices

Description : Which instrument is used to monitor O2, CO in flue gas? (EA) a) Combustion analyser b) Power analyser c) Pyrometer d) Fyrite

Last Answer : Combustion analyser

Description : instrument is used to monitor O2, CO in flue gas (EA) a) Combustion analyzer b) Power analyzer c) Pyrometer d) Fyrite

Last Answer : Combustion analyzer

Description : Which instrument is used to monitor O2, CO in flue gas? c)Combustion analyzer c) Pyrometer d)Power analyzer d) Fyrite

Last Answer : Combustion analyzer

Description : 115. Which instrument is used to monitor O2, CO in flue gas? a) Combustion analyzer c) Pyrometer b) Power analyzer d) Fyrite

Last Answer : Combustion analyzer

Description : To maximize the combustion efficiency, which of the following in the flue gas needs to be done? a) maximize O2 b) maximize CO2 c) minimize CO2 d) maximize CO

Last Answer : b) maximize CO2

Description : Which among the following has the highest flue gas loss on combustion due to Hydrogen in the fuel? a) natural gas b) furnace oil c) coal d) light diesel oil

Last Answer : a) natural gas

Description : Name THREE TECHNIQUES for removing particulates from flue gas produced from the combustion of coal?

Last Answer : (1) ELECTROSTATIC PRECIPITATION (ESP) (2) FABRIC FILTER OR BAGHOUSE (3) WET SCRUBBERS (4) MECHANICAL COLLECTORS OR CYCLONES

Description : The sequence of absorption in flue gas analysis by Orsat's apparatus is respectively (A) CO2 , O2 , CO (B) CO, O2 , CO2 (C) CO2 , CO, O2

Last Answer : (A) CO2 , O2 , CO

Description : Orsat apparatus (A) Gives flue gas analysis on dry basis (B) Determines N2 in flue gas indirectly (C) Can’t determine CO in flue gas, if it is < 0.2% (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : In flue gas analysis by Orsat's apparatus, oxygen is absorbed by (A) Potassium hydroxide (B) Cuprous chloride (C) Alkaline pyrogallol solution

Last Answer : (C) Alkaline pyrogallol solution