State the meaning of energy meter constant K. State its unit.

1 Answer

Answer :

Meaning of Energy Meter Constant (K):

Energy Meter Constant is the no. of revolutions made by disc in meter per unit (kWh) consumption of energy.

Unit of energy meter constant K is rev/kWH

Related questions

Description : State the advantages of electronic energy meter. 

Last Answer : Advantages of Electronic Energy Meter: 1) Low cost. 2) High accuracy. 3) More flexibility. 4) High sensitivity 5) No frictional losses. 6) Less loading effect. 7) High frequency ... for external adjustment. 11) Low load, full load, power factor and creeping adjustments are not required.

Description : Explain the calibration of single phase electronic energy meter using direct loading.

Last Answer : Calibration of Single-phase Electronic Energy Meter by Direct Loading Method: The following figure shows the arrangement of calibration for single phase electronic energy meter. A phase shifter is connected for ... are taken for different values of current at different power factors. 

Description :  Draw a neat labeled block diagram of 3-phase Electronic Energy meter.

Last Answer : Labeled diagram of 3-phase electronic energy meter:

Description : Describe with block diagram; the construction of single phase electronic energy meter. 

Last Answer : Construction of Single Phase Electronic Energy Meter: 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the ... The ADC converts the square wave frequency analog output to display the energy in Watt-hour.

Description : List the errors occuring in single phase electronic energy meter.

Last Answer : Errors in Single Phase Electronic Energy Meter: 1) Error due to wrong sensor opeartion. 2) Error due to temperature. 3) Error due to wrong CT opeartion. 4) Error due to wrong PT opeartion. 5 ... of scaling network. 6) Error due to wrong ADC opeartion. 7) Error due to wrong Display. 

Description : Draw the block diagram of tri-vector meter. State the various measurements possible from tri-vector meter.

Last Answer : Various measurements possible from tri-vector meter are: Tri-vector meter is a measuring instrument which measures the kWh, kVArh, the kVAh of a power line. Tri-vector meter is an energy meter ... of supply such as voltage, current, power factor, active load, reactive load, apparent load etc.

Description : State the purpose of four quadrant meter.

Last Answer : Purpose of four quadrant meter:  Four-quadrant meter is basically a bidirectional energy-meter with additional measurement facility. The purposes of four-quadrant meter are: 1) Measurement of energy/power ... and kVARh 3) Time-of-use metering: Bidirectional consumption and demand.

Description : Define electrical energy. State its unit.

Last Answer : Electrical Energy: Electrical energy is defined as the work done in moving electrical charge in electrical field. OR The total power delivered or consumed by electrical load over specific unit time ... unit of electrical energy is the joule (or watt-second) OR Kilowatt-hour ( kWH ).

Description : Describe with block diagram the working of digital frequency meter.

Last Answer : Digital frequency meter: Amplifier: The signal whose frequency is to be measured is first amplified and supplied to the schmitt trigger. Schmitt Trigger: The schmitt trigger convert ... count displayed on counter  t = time interval between start and stop condition of the gate 

Description : Draw block diagram of function generator and state the function of each block. 

Last Answer : Block Diagram of Function Generator: OR Working of Function Generator : This instrument can deliver sine, triangular & square waves with frequency range of 0.01 Hz to ... output voltage reaches a predetermined level on the negative slope of the integrator's output voltage. 

Description : State the purpose of calibration of measuring instruments. Explain the procedure of calibration of D.C. voltmeter by using D.C. potentiometer.

Last Answer : Purpose of calibration : Calibration is the process of evaluating and adjusting the precision and accuracy of measuring equipment. Proper calibration of an instrument allows people to have a safe ... calibration curve can be drawn by plotting the percentage error against the measured voltages. 

Description : List the types of systematic errors and state the reasons due to which these errors occur.

Last Answer : Systematic Error: i) Instrumental Error: These errors are caused due to the mechanical structure of measuring instrument such as: a) Inherent shortcomings of instruments: Instrument may ... or electrostatic fields. iii) Observational Error: Parallax errors, incorrect multiplying factor.

Description : State the working principle of PMMC Analog instrument.

Last Answer : Working Principal of PMMC Analog Instrument: When current carrying conductor is placed in a magnetic field, it experiences mechanical force. In PMMC instrument, when current flows through a coil ... coil rotates and pointer attached to the coil shows deflection proportional to the current magnitude.

Description : State the use of synchroscope.

Last Answer : Use of Synchroscope: The synchroscope is used to determine the exact instant of switching required to connect the alternators in parallel or put an alternator in parallel with the infinite bus. ... idea of the faster or slower machine to make adjustments in speed of alternators for synchronising.

Description : Explain with neat sketch the construction and working principle of megger.

Last Answer : Megger: Construction of Megger : Two coils: the current coil and pressure coil are mounted at an angle on the same spindle and form the part of the moving system. These coils are ... force produces a torque that is used to deflect the pointer of the device which gives some reading.

Description : Describe the procedure for the measurement of earth resistance by using earth tester.

Last Answer : Measurement of earth resistance by using earth tester:  It is connected to earth electrode E, whose resistance is to be measured, and the other spike P and R, as shown in the ... , the deflection of the pointer will indicate directly resistance in ohm of the earth electrode under test. 

Description : Explain the effect of power factor on wattmeter reading in two wattmeter method for power measurement.

Last Answer : Effect of P.F. on Reading of Wattmeter in Two Wattmeter Method:

Description : Explain with neat sketch; the construction and working principle of Repulsion type moving iron instrument.

Last Answer : Repulsion Type Moving Iron Instrument: Construction: It consist of fixed cylinder hollow coil which carries operating current inside the coil there are two soft iron pieces. One of which is ... magnetized with same polarity a repulsive force act on them and moving iron piece gets deflected. 

Description : Describe with suitable example; frequency measurement by Lissajous patterns on CRO. 

Last Answer : * Initially the unknown frequency signal is connected to vertical deflection plates of CRO. * Now switch of the internal sweep generator of the horizontal deflecting system. * A standard source ... explain by following example: Assume horizontal input frequency is 10 kHz for following pattern

Description : Describe with block diagram; the principle of operation of digital storage oscilloscope.

Last Answer : The block diagram of DSO is shown above. Sampling rate may be as high as 1,00,000 samples per sencod. For such high sampling rates, a fast conversion ADC is requried. Flash ADC ... particular signal in the memory then overwritting should be stopped.This obtained by using Hold and Save button.

Description : Explain the error occurred due to pressure coil inductance of electrodynamometer type wattmeter. How this error is compensated?

Last Answer : For power measurement assume that the pressure coil of wattmeter is purely restitive. Hence current taken by pressure coil Ipc is in phase with voltage across the pressure coil Vpc  ... inductive reactance XL the pressure coil circuit is made purely resistive and the error is eliminated.

Description : Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

Last Answer : (i) Measurement of active power in 3- phase load circuit using two- wattmeter: (ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

Description : Explain with neat sketch, the working of full wave rectifier voltmeter.

Last Answer : Full Wave Rectifier Type Voltmeter: Working of full wave rectifier type A. C. Voltmeter Referring to the circuit diagram, for rectification, a full wave bridge circuit (ABCD) is used. Input ... current passing through meter is given as, which causes full scale deflection of the meter.

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : Compare analog instrument to digital instrument on the basis of accuracy, resolution, power required and portability. 

Last Answer : Comparison between Analog instruments & Digital instruments: 

Description : A single phase wattmeter rated for 500 V; 5A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?

Last Answer : Answer :

Description : Calculate the resistance of shunt required to make a milliammeter which gives maximum deflection for a current of 15 mA and which has a resistance of 5 Ω; read up to 10 Amp.

Last Answer : Answer :

Description : Differentiate between analog and digital multimeter.

Last Answer : Analog multimeter Digital multimeter 1. Power supply is not required 1. Power supply is required 2. Less suffered from electric noise 2. Suffered from electric noise 3. It provides measurement ... 9. Bigger in size 9. Compact in size 10. Economical 10.Expensive

Description : “Secondary of current transformer should not be open”. Justify.

Last Answer : Secondary of a CT should not be Open Circuited: If secondary of CT is open circuited ,then current through secondary becomes zero hence the ampere-turns produced by secondary which generally opposes primary ... opeartor point of view as well. So secondary of a CT should not be open circuited. 

Description : Describe different types of errors in analog measuring instruments. 

Last Answer : Types of Errors in Analog Measuring Instruments: A) Gross error: These are due to mistakes on the part of person using the instrument. B) Systematic Error: It has three sub types as ... multiplying factor. C) Random error: These persist even after gross and systematic errors are removed.

Description : Give ranges of low and high resistances.

Last Answer : 1) Ranges of low resistance: Less than 1 ohm.  2) Ranges of high resistance: Greater than 0.1 Mega ohm.

Description : The value of the product of molecular weight and the gas characteristic constant for all the gases in M.K.S. unit is  (a) 29.27 kgfm/mol°K  (b) 8314kgfm/mol°K  (c) 848kgfm/mol°K  (d) 427kgfm/mol°K  (e) 735 kgfm/mol°K.

Last Answer : Answer : c

Description : A spring with a force constant of 20 newtons per meter is known to obey Hooke's Law. The spring is attached to a mass of 5 kilograms and placed on a horizontal, frictionless surface. The ... and released. What is the kinetic energy of the mass as it passes through its equilibrium position? 

Last Answer : ANSWER: 90 JOULES

Description : What is meant by energy meter constant?

Last Answer : Energy Meter Constant  A fixed value which is used when converting meter readings to actual energy use, especially when potential transformers and similar types of equipment are used in metering. For example, K=--------rev/Kwh

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description : A single phase energy meter has a constant of 1200 revolution/kWh. When a load of 200 W is connected, the disc rotates at 4.2 revolutions per min. If the load is on for 10 hours, the meter records an excess of   (a) 0.1 kWh (b) 0.2 kWh (c) 1.0 kWh (d) 2.0 kWh 

Last Answer : 2

Description : An energy meter has a constant of 600 rev/kWh. If the meter makes 10 revolutions in 20 s, what is the load in kW?  (A) 0.75 kW (B) 1.5 kW (C) 3 kW (D) 6 kW 

Last Answer : 1.5 kW 

Description : The unit of work or energy in S.I. units is (A) Newton (B) Pascal (C) Kilogram meter (D) Joule

Last Answer : (D) Joule

Description : Which of the following statement is false? a.The potential energy of a particle has the form Ep = k2x. The force acting on the particle is constant (k is a constant) b.The linear velocity of ... zag path while ascending a steep hill e.The density of milk decreases when cream is taken out of milk

Last Answer : e. The density of milk decreases when cream is taken out of milk

Description : Pick out the wrong statement. (A) A particular chemical reaction is more temperature sensitive at low temperatures (B) A very high value of equilibrium constant, K (K >> 1) indicates that the ... ) Non-ideal flow takes place in reactors due to recycling, channeling or by creation of stagnant regions

Last Answer : (C) The intercept of the Arrhenius plot is called the 'activation energy

Description : The rate expression for a heterogeneous catalytic reaction is given by, - rA = K.KA PA(1 + KA.PA + KR.PR), where K is surface reaction rate constant and KA and KR are absorption equilibrium constants of A and R respectively. If KR PR ... R and A) (A) E (B) E + ΔHA (C) E + ΔHA - ΔHR ) (D) ΔHA + ΔHR

Last Answer : (C) E + ΔHA - ΔHR )

Description : Pick out the wrong statement. (A) Visible radiation provides the necessary activation energy in photochemical reactions (B) The order and molecularity of a complex reaction may not be the same (C) For ... rate constant (k) (D) Molecularity of the reaction is always a whole number greater than zero

Last Answer : (B) The order and molecularity of a complex reaction may not be the same

Description : The free energy change for a chemical reaction is given by (where, K = equilibrium constant) (A) RT ln K (B) -RT ln K (C) -R ln K (D) T ln K

Last Answer : (B) -RT ln K

Description : The noise output of a resistor is amplified by a noiseless amplifier having a gain of 60 and a bandwidth of 20 kHz. A meter connected at the output of the amplifier reads 1mV RMS. If the bandwidth of the amplifier is reduced to ... does the meter read now? A. 0.5 mV B. 0.5 µV C. 5.0 mV D. 5.0 µV

Last Answer : A. 0.5 mV

Description : Rittinger number which designates the new surface produced per unit of mechanical energy absorbed by the material being crushed, depends on the (A) State or manner of application of the crushing force (B) Ultimate strength of the material (C) Elastic constant of the material (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : State the meaning of creeping error in 1 phase energy meter.

Last Answer : Creeping error: It is defined as the slow and continuous rotation of the disc of the energy-meter when only pressure coil is energized with no current in the current coil (load current = 0). ... magnet on this iron wire is sufficient to prevent continues rotation of the disc on no load condition.

Description : On meter length of wires carriers a constant current. The wire is bent to from a circular loop. The magnetic field at the centre of this loop is `B`.

Last Answer : On meter length of wires carriers a constant current. The wire is bent to from a circular loop. The magnetic field at ... B. `4B` C. `B/4` D. `16B`

Description : The pressure head of a flow meter remains constant for (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : In area meter (e.g., Rotameter), with increase in the fluid flow rate, the (A) Pressure drop increases linearly (B) Pressure drop is almost constant (C) Area through which fluid flows does not vary (D) None of these

Last Answer : (B) Pressure drop is almost constant