Multipass heat exchangers are used
(A) Because of simplicity of fabrication
(B) For low heat load
(C) To obtain higher heat transfer co-efficient and shorter tube
(D) To reduce the pressure drop

1 Answer

Answer :

(C) To obtain higher heat transfer co-efficient and shorter tube

Related questions

Description : Pick out the wrong statement. (A) Superheated steam is preferably not used for process heating because of its low heat transfer film co-efficient (B) In a shell and tube heat exchanger ... surface heat exchangers, when the direction of fluid flow is parallel to the axis of the tube

Last Answer : (C) S.I. unit of fouling factor is Watt/m2 .°K

Description : Which of the following parameters is increased by use of finned tube in a multipass shell and tube heat exchanger? (A) Tube side pressure drop and the heat transfer rate (B) Convective heat transfer co-efficient (C) Effective tube surface area for convective heat transfer (D) All (A) (B) and (C)

Last Answer : (D) All (A) (B) and (C)

Description : For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it (A) Decreases the pressure drop (B) ... the outlet temperature of cooling medium (C) Increases the overall heat transfer coefficient (D) None of these

Last Answer : (C) Increases the overall heat transfer coefficient

Description : Extremely large or small volumes of fluids are generally best routed through the shell side of a shell and tube heat exchanger, because of the (A) Less corrosion problems (B) Flexibility possible in the baffle arrangement (C) Low pressure drop (D) High heat transfer co-efficient

Last Answer : (B) Flexibility possible in the baffle arrangement

Description : The advantage of using a 1 - 2 shell and tube heat exchanger over a 1 - 1 shell and tube heat exchanger is (A) Lower tube side pressure drop (B) Lower shell side pressure drop (C) Higher tube side heat transfer co-efficient (D) Higher shell side heat transfer co-efficient

Last Answer : (C) Higher tube side heat transfer co-efficient

Description : In a shell and tube heat exchanger, floating head is used for (A) Large temperature differentials (B) High heat transfer co-efficient (C) Low pressure drop (D) Less corrosion of tubes

Last Answer : (A) Large temperature differentials

Description : Finned tube heat exchangers (A) Give larger area per tube (B) Use metal fins of low thermal conductivity (C) Facilitate very large temperature drop through tube wall (D) Are used for smaller heat load

Last Answer : (A) Give larger area per tube

Description : Double pipe heat exchangers are preferably useful, when (A) High viscosity liquid is to be cooled (B) Requirement of heat transfer area is low (C) Overall heat transfer co-efficient is very high (D) A corrosive liquid is to be heated

Last Answer : (B) Requirement of heat transfer area is low

Description : Indirect contact heat exchangers are preferred over direct contact heat exchangers, because (A) Heat transfer co-efficient are high (B) There is no risk of contamination (C) There is no mist formation (D) Cost of equipment is lower

Last Answer : (B) There is no risk of contamination

Description : Pick out the wrong statement. (A) In drying a solid containing moisture above the critical moisture content the number of degrees of freedom is 2 (B) Sherwood number in mass transfer corresponds to ... tube heat exchangers. At higher pressure, however, it is customary to put gas in the tube side

Last Answer : (C) Forced convection is relatively more effective in increasing the rate of mass transfer, if Schmidt number is larger

Description : Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2 .°C. Condensation of vapor is carried out inside the tube in a shell and tube heat ... drop through the exchanger is desired (D) Temperature of the incoming vapor is very high

Last Answer : (B) Supersaturated

Description : Baffles are provided in heat exchangers to increase the (A) Fouling factor (B) Heat transfer area (C) Heat transfer co-efficient (D) Heat transfer rate

Last Answer : (C) Heat transfer co-efficient

Description : Heat exchangers operating, when the asymptotic range is reached, (A) Provide very large heat transfer co-efficient (B) Results in making part of the heating surface inactive (C) Results in abruptly increased velocity (D) None of these

Last Answer : (B) Results in making part of the heating surface inactive

Description : In case of a multipass shell and tube heat exchanger, the temperature drop in the fluid (A) Is inversely proportional to the resistance across which the drop occurs (B) And the wall are proportional to individual resistances (C) And the wall is not related (D) None of these

Last Answer : (B) And the wall are proportional to individual resistances

Description : In case of a multipass shell and tube heat exchanger, providing a baffle on the shell side __________ the heat transfer rate. (A) Increases (B) Decreases (C) Does not affect (D) May increase or decrease, depends on the type of baffle

Last Answer : (A) Increases

Description : In an extended surface heat exchanger, fluid having lower co-efficient (A) Flows through the tube (B) Flows outside the tubes (C) Can flow either inside or outside the tubes (D) Should not be used as it gives very high pressure drop

Last Answer : (B) Flows outside the tubes

Description : . A dilute aqueous solution is to be concentrated in an evaporator system. High pressure steam is available. Multiple effect evaporator system is employed, because (A) Total heat transfer area of ... in a single effect is much lower than that in any effect in a multi-effect system

Last Answer : (B) Total amount of vapor produced per Kg of feed steam in a multiple effect system is much higher than in a single effect

Description : Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both ... steam on shell side (D) Shell and tube heat exchanger with air on shell side and steam inside tubes

Last Answer : (B) Finned tube heat exchanger with air outside and steam inside

Description : Double pipe heat exchangers are used (A) When heat transfer area required is very high (B) When heat transfer area required is very low, i.e. (100-200 ft 2 ). (C) Because it occupies less floor area (D) Because it is less costly

Last Answer : (B) When heat transfer area required is very low, i.e. (100-200 ft 2 )

Description : In a multipass shell and tube heat exchanger, tube side return pressure loss is equal to __________ the velocity head. (A) Twice (B) Four times (C) Square root of (D) Square of

Last Answer : (B) Four times

Description : What is the method of determining maximum differential pressure during hydro testing of shell and tube heat exchangers?

Last Answer : Mr. Richard Lee of Plumlee International Consulting usually heat exchangers have two sets of test pressures per side, one for strength tests, and the other for operating or leak tests. The ... . The acceptability of this lower pressure test will often depend upon the consequences of a leak.

Description : . In a shell and tube heat exchanger, the tube side heat transfer co￾efficient just at the entrance of the tube is (A) Infinity (B) Zero (C) Same as average heat transfer co-efficient for tube side (D) None of these

Last Answer : (A) Infinity

Description : Convective heat transfer co-efficient in case of fluid flowing in tubes is not affected by the tube length/diameter ratio, if the flow is in the __________ zone. (A) Laminar (B) Transition (C) Both 'a' & 'b' (D) Highly turbulent

Last Answer : (D) Highly turbulent

Description : Steam is to be condensed in a shell and tube heat exchanger, 5 m long with a shell diameter of 1 m. Cooling water is to be used for removing the heat. Heat transfer co-efficient ... ) Horizontal heat exchanger with steam on tube side (D) Horizontal heat exchanger with steam on shell side

Last Answer : (B) Vertical heat exchanger with steam on shell side

Description : Baffles in the shell side of a shell and tube heat exchanger (A) Increase the cross-section of the shell side liquid (B) Force the liquid to flow parallel to the bank (C) Increase the shell side heat transfer co-efficient (D) Decrease the shell side heat transfer co-efficient

Last Answer : (C) Increase the shell side heat transfer co-efficient

Description : For turbulent flow in a tube, the heat transfer co-efficient is obtained from the Dittus-Boelter correlation. If the tube diameter is halved and the flow rate is doubled, then the heat transfer co-efficient will change by a factor of (A) 1 (B) 1.74 (C) 6.1 (D) 37

Last Answer : (C) 6.1

Description : In case of vertical tube evaporator, with increase in liquor level, the overall heat transfer co-efficient (A) Increases (B) Decreases (C) Is not affected (D) May increase or decrease; depends on the feed

Last Answer : (B) Decreases

Description : The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by __________ times, when the number of tube passes is increased to 8. (A) 2 0.8 (B) 4 0.8 (C) 4 0.4 (D) 2 0.4

Last Answer : (B) 4 0.8

Description : Overall heat transfer co-efficient of a particular tube is U1 . If the same tube with some dirt deposited on either side has coefficient U2 , then (A) U1 = U2 (B) U2 > U1 (C) U1 > U2 (D) U1 = dirt factor - U2

Last Answer : (A) U1 = U2

Description : The overall heat transfer co-efficient for a shell and tube heat exchangerfor clean surfaces is U0 = 400 W/m2 .K. The fouling factor after one year of operation is found to be hd0 = 2000 W/m2 .K. The overall heat transfer co￾efficient ... 1200 W/m2 .K (B) 894 W/m2 .K (C) 333 W/m2 .K (D) 287 W/m2 .K

Last Answer : (C) 333 W/m2 .K

Description : Pick out the wrong statement. (A) 'Solvates' are chemical compounds formed by solute with their solvents. When water is the solvent, then it is called a 'hydrate' (B) In heat exchanger ... vertical evaporators, area of central downtake is about 50 to 100% of the total tube cross-sectional area

Last Answer : (C) Heat transfer co-efficient during nucleate boiling is not influenced by the agitation imparted

Description : For a laminar flow of fluid in a circular tube, 'h1 ' is the convective heat transfer co-efficient at velocity 'V1 '. If the velocity is reduced by half and assuming the fluid properties are constant, the new convective heat transfer co-efficient is (A) 1.26 h1 (B) 0.794 h1 (C) 0.574 h1 (D) 1.741 h1

Last Answer : (B) 0.794 h1

Description : Fouling factor' used in the design of a multipass shell and tube heat exchanger is a (A) Non-dimensional factor (B) Factor of safety

Last Answer : (B) Factor of safety

Description : Tube expansion allowances exist in __________ heat exchanger. (A) Multipass fixed tube sheet (B) U-tube (C) Single pass fixed tube sheet (D) None of these

Last Answer : (B) U-tube

Description : The ratio of velocity head to tube side return loss in case of a multipass shell and tube heat exchanger is (A) 2 (B) 1/2 (C) 4 (D) 1/4

Last Answer : (D) 1/4

Description : For a multipass shell and tube heat exchanger, the LMTD correction factor is always (A) 1 (B) > 1 (C) < 1 (D) Between 1 & 2

Last Answer : (C) < 1

Description : Even though bubble cap towers are very effective for humidification operation, they are not used commonly in industries, because of the (A) High evaporation losses of water (B) High pressure drop of the gas (C) Difficulty in its fabrication (D) None of these

Last Answer : (B) High pressure drop of the gas

Description : Pick out the wrong statement. (A) The condensing film co-efficient is about 3 times lower for vertical condenser as compared to the equivalent horizontal condenser for identical situation ( ... in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Last Answer : (D) Overall heat transfer co-efficient in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Description : If h1 = inner film co-efficient and /h2 = outer film co-efficient, then the overall heat transfer co-efficient is (A) Always less than h1 (B) Always between h1 and h2 (C) Always higher than h2 (D) Dependent on metal resistance

Last Answer : (B) Always between h1 and h2

Description : To reduce the tube side pressure drop for the same flow rate, the heat exchanger recommended is (A) 1-2 heat exchanger (B) 1-1 heat exchanger (C) 3-2 heat exchanger (D) 2-4 heat exchanger

Last Answer : (B) 1-1 heat exchanger

Description : Pick out the wrong statement. (A) Heat transfer by radiation cannot occur across an absolute volume (B) In case of a shell and tube heat exchanger, the pressure drop through the shell is ... The amount of heat involved in the condensation or vaporisation of 1 kg of a fluid is the same

Last Answer : (A) Heat transfer by radiation cannot occur across an absolute volume

Description : Pick out the wrong statement. (A) Economy of a multiple effect evaporator is not influenced by the boiling point elevation (B) Two identical cubes of iron and copper will have the same heat ... in the field of refrigeration (D) Finned tube heat exchangers are suitable for heating air by steam

Last Answer : (B) Two identical cubes of iron and copper will have the same heat content under the same conditions of temperature

Description : Is there a difference in MTD (Mean Temperature Difference) between “E” and “J” (Divided Flow) type shell and tube heat exchangers?

Last Answer : Divided flow (shell type J) does not have the same correction as the usual flow pattern (shell type E). Thermal design program make this correction factor mistake. True, there is very little ... for the above examples and it is hard to read in this range. Source: Gulley Computer Associates

Description : Why is a vacuum breaker used on shell and tube heat exchangers that are utilizing steam as the heating utility?

Last Answer : Vacuum breakers are often installed on the shell side (steam side) of shell and tube exchangers to allow air to enter the shell in case of vacuum conditions developing inside the shell. For an ... vacuum in the shell could allow condensate to build in the unit and water hammer may result.

Description : In a shell and tube heat exchanger, square pitch compared to triangular pitch (A) Gives a higher shell side pressure drop (B) Gives a lower shell side pressure drop (C) Can pack more surface area into a shell of given diameter (D) None of these

Last Answer : (A) Gives a higher shell side pressure drop

Description : An ideal coolant for a nuclear reactor should (A) Be a good absorber of neutrons (B) Be capable of attaining high temperature, only when it is pressurised (C) Have high density, but low heat transfer co-efficient (D) Be free from radiation damage and non-corrosive

Last Answer : (D) Be free from radiation damage and non-corrosive

Description : What is some good advice for specifying allowable pressure drops in shell and tube exchangers for heavy hydrocarbons?

Last Answer : Frequently process engineers specify 5 or 10 PSI for allowable pressure drop inside heat exchanger tubing. For heavy liquids that have fouling characteristics, this is usually not enough. There are ... the heat exchanger of approximately 40%. This savings offset the cost of the pumping power

Description : What is the use of shell and tube heat exchangers?

Last Answer : shell and tube heat exchangers are used mostly in the chemical processing industry for heating, cooling, condensing, and evaporating highly corrosive liquids and gases.AMETEK ... fluoropolymer heat exchangers are Hydrochloric, Nitric and Hydrofluoric Acids. Another chemical manufacturing indust

Description : Pick out the wrong statement. (A) Longer tubes are less expensive per unit heat transfer area as compared to shorter tubes (B) A cost index is merely a number for a given year ... butt welded joints are less expensive compared to lap welded joints, because squaring of plates is not necessary

Last Answer : (D) Plates with butt welded joints are less expensive compared to lap welded joints, because squaring of plates is not necessary

Description : Film boiling is usually not desired in commercial equipments, because (A) The heat transfer rate is low in view of the large temperature drop (B) It is difficult to maintain (C) It is not economic (D) None of these

Last Answer : (A) The heat transfer rate is low in view of the large temperature drop