Pick out the wrong statement.
(A) 'Solvates' are chemical compounds formed by solute with their solvents.
When water is the solvent, then it is called a 'hydrate'
(B) In heat exchanger calculations (Δt) weighted is used in place of Δt, when
it involves more than one sequence of heating or cooling i.e., desuperheating &
condensation or condensation & sub-cooling
(C) Heat transfer co-efficient during nucleate boiling is not influenced by the
agitation imparted
(D) In case of short tube vertical evaporators, area of central downtake is
about 50 to 100% of the total tube cross-sectional area

1 Answer

Answer :

(C) Heat transfer co-efficient during nucleate boiling is not influenced by the
agitation imparted

Related questions

Description : Pick out the wrong statement. (A) The condensing film co-efficient is about 3 times lower for vertical condenser as compared to the equivalent horizontal condenser for identical situation ( ... in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Last Answer : (D) Overall heat transfer co-efficient in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Description : Pick out the wrong statement. (A) In case of heat transfer by purely forced convection, GR /Re 2 ≤ 1 (B) The equivalent diameter of heat transfer for a duct of ... nucleate boiling depends basically on the ease with which the bubbles are formed and detached from the heating surface

Last Answer : (B) The equivalent diameter of heat transfer for a duct of square cross￾section (having each side as 'x') is equal to 4x

Description : Pick out the wrong statement. (A) Superheated steam is preferably not used for process heating because of its low heat transfer film co-efficient (B) In a shell and tube heat exchanger ... surface heat exchangers, when the direction of fluid flow is parallel to the axis of the tube

Last Answer : (C) S.I. unit of fouling factor is Watt/m2 .°K

Description : Pick out the wrong statement: (A) The capacity of an evaporator is reduced by the boiling point elevation (B) Corrosive liquid is normally passed through the tubes in a ... recompression evaporator (D) Heat sensitive materials should be concentrated in high pressure evaporators

Last Answer : (D) Heat sensitive materials should be concentrated in high pressure evaporators

Description : Steam is to be condensed in a shell and tube heat exchanger, 5 m long with a shell diameter of 1 m. Cooling water is to be used for removing the heat. Heat transfer co-efficient ... ) Horizontal heat exchanger with steam on tube side (D) Horizontal heat exchanger with steam on shell side

Last Answer : (B) Vertical heat exchanger with steam on shell side

Description : Pick out the wrong statement. (A) Heat transfer by radiation cannot occur across an absolute volume (B) In case of a shell and tube heat exchanger, the pressure drop through the shell is ... The amount of heat involved in the condensation or vaporisation of 1 kg of a fluid is the same

Last Answer : (A) Heat transfer by radiation cannot occur across an absolute volume

Description : Pick out the wrong statement. (A) The controlling resistance in case of heating of air by condensing steam is in the air film (B) The log mean temperature difference (LMTD) for ... a pure fluid at a given pressure from liquid to vapor or vice-versa occurs at saturation temperature

Last Answer : (C) In case of a 1 - 2 shell and tube heat exchanger, the LMTD correction factor value increases sharply, when a temperature cross occurs

Description : Pick out the wrong statement. (A) Economy of a multiple effect evaporator is not influenced by the boiling point elevation (B) Two identical cubes of iron and copper will have the same heat ... in the field of refrigeration (D) Finned tube heat exchangers are suitable for heating air by steam

Last Answer : (B) Two identical cubes of iron and copper will have the same heat content under the same conditions of temperature

Description : Pick out the wrong statement about nucleate boiling. (A) Bubble generation is by expansion of entrapped gas/vapour at small cavities in the surface (B) Surface temperature is greater than the saturation ... less than that in film boiling (D) The temperature is less than that of film boiling

Last Answer : (D) The temperature is less than that of film boiling

Description : Even though heat transfer co-efficient in boiling liquids is large, use of fins is advantageous, when the entire surface is exposed to __________ boiling. (A) Film (B) Nucleate (C) Transition (D) All modes of

Last Answer : Option A

Description : Baffles in the shell side of a shell and tube heat exchanger (A) Increase the cross-section of the shell side liquid (B) Force the liquid to flow parallel to the bank (C) Increase the shell side heat transfer co-efficient (D) Decrease the shell side heat transfer co-efficient

Last Answer : (C) Increase the shell side heat transfer co-efficient

Description : Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2 .°C. Condensation of vapor is carried out inside the tube in a shell and tube heat ... drop through the exchanger is desired (D) Temperature of the incoming vapor is very high

Last Answer : (B) Supersaturated

Description : Pick out the wrong statement. (A) In a first order reaction, A → products; the reaction becomes slower as it proceeds, because the concentration of A decreases and the rate is proportional to the concentration ... irreversible reaction, A + B → 2C is k.CA .CB , then the reaction is always elementary

Last Answer : (C) According to the penetration theory, the mass transfer co-efficient decreases, if the exposure time of an eddy to the solute decreases

Description : The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by __________ times, when the number of tube passes is increased to 8. (A) 2 0.8 (B) 4 0.8 (C) 4 0.4 (D) 2 0.4

Last Answer : (B) 4 0.8

Description : Pick out the wrong statement regarding the solubility characteristics of high polymers. (A) Greater the degree of cross-linking in the polymer, lesser is its solubility (B) Polymers having more ... of the solvent (D) High molecular weight polymers on dissolving gives solution of very low viscosity

Last Answer : (D) High molecular weight polymers on dissolving gives solution of very low viscosity

Description : Pick out the wrong statement. (A) Bubble size increases with the dynamic viscosity of the liquid in case of nucleate pool boiling (B) Thermal conductivity of a dry material is more than ... in kg/hr in an evaporator (D) Vaporisation of organic substances in evaporator mostly causes foam formation

Last Answer : (B) Thermal conductivity of a dry material is more than that of the damp material

Description : Pick out the wrong statement. (A) Heat transfer from a hot body to cold body by the emission of heat waves is called radiation (B) Filmwise condensation takes place on non-wettable surfaces (C) The ... of a solution is affected by liquid head as well as boiling point elevation (D) None of these

Last Answer : (B) Filmwise condensation takes place on non-wettable surfaces

Description : Which of the following parameters is increased by use of finned tube in a multipass shell and tube heat exchanger? (A) Tube side pressure drop and the heat transfer rate (B) Convective heat transfer co-efficient (C) Effective tube surface area for convective heat transfer (D) All (A) (B) and (C)

Last Answer : (D) All (A) (B) and (C)

Description : Pick out the wrong statement. (A) In the McCabe-Thiele diagram for binary distillation, vertical feed line represents saturated liquid feed and horizontal feed line represents saturated vapour feed (B) In ... layers over a flat plate are of equal thickness, if Schmidt number is equal to unity

Last Answer : (C) For Laminar flow over a plate of length L, the local mass transfer co￾efficient at a distance L from the leading edge is 1.5 × 10 -2m/s. Then the average mass transfer co-efficient for the plate is 2 × 10 -2m/s

Description : Pick out the wrong statement. (A) The value of hydrostatic head increases with increase in vacuum in the effect in a multiple effect evaporator system (B) Entering velocity of the liquid in ... a multiple effect evaporation system, the number of effects is limited by the total boiling point rise

Last Answer : (C) Duhring's plot is used for calculating the concentration of solution

Description : In case of vertical tube evaporator, with increase in liquor level, the overall heat transfer co-efficient (A) Increases (B) Decreases (C) Is not affected (D) May increase or decrease; depends on the feed

Last Answer : (B) Decreases

Description : In a co-current double pipe heat exchanger used for condensing saturated steam over the inner tube, if the entrance and exit conditions of the coolant are interchanged, then the rate of condensation ... Decrease (C) Remain unchanged (D) Either increase or decrease; depends on the coolant flow rate

Last Answer : (C) Remain unchanged

Description : . In a shell and tube heat exchanger, the tube side heat transfer co￾efficient just at the entrance of the tube is (A) Infinity (B) Zero (C) Same as average heat transfer co-efficient for tube side (D) None of these

Last Answer : (A) Infinity

Description : The advantage of using a 1 - 2 shell and tube heat exchanger over a 1 - 1 shell and tube heat exchanger is (A) Lower tube side pressure drop (B) Lower shell side pressure drop (C) Higher tube side heat transfer co-efficient (D) Higher shell side heat transfer co-efficient

Last Answer : (C) Higher tube side heat transfer co-efficient

Description : Extremely large or small volumes of fluids are generally best routed through the shell side of a shell and tube heat exchanger, because of the (A) Less corrosion problems (B) Flexibility possible in the baffle arrangement (C) Low pressure drop (D) High heat transfer co-efficient

Last Answer : (B) Flexibility possible in the baffle arrangement

Description : In a shell and tube heat exchanger, floating head is used for (A) Large temperature differentials (B) High heat transfer co-efficient (C) Low pressure drop (D) Less corrosion of tubes

Last Answer : (A) Large temperature differentials

Description : Nucleate boiling is promoted (A) On polished surfaces (B) On rough surfaces (C) In the absence of agitation (D) None of these

Last Answer : (B) On rough surfaces

Description : Pick out the wrong statement. (A) In solvent extraction, the distribution co-efficient should be as large as possible for solvent economy (B) With increase in pressure, the solubility of ... in distillation column (D) The capacity of a distillation column is maximum at total reflux

Last Answer : (D) The capacity of a distillation column is maximum at total reflux

Description : Pick out the wrong statement: (A) Change in barometric pressure does not affect the relative humidity (B) In case of a packed tower, the operating velocity is about half of the ... (D) The equilibrium moisture content of the solid can be reduced by increasing the absolute humidity

Last Answer : (D) The equilibrium moisture content of the solid can be reduced by increasing the absolute humidity

Description : Pick out the wrong statement. (A) Mechanical agitation is required, if the system has low interfacial tension (B) Sieve tray towers are generally used for systems having low ... Prandtl analogy for heat and mass transfer considers the transfer through both laminar and turbulent layers

Last Answer : (A) Mechanical agitation is required, if the system has low interfacial tension

Description : Heat transfer co-efficient equation for forced convection, Nu = 0.023 Re 0.8 . Pr n , is not valid, if the value of (A) n = 0.4 is used for heating (B) n = 0.3 is used for cooling (C) Reynolds number for the flow involved is > 10000 (D) Reynolds number for the flow involved is < 2100

Last Answer : (D) Reynolds number for the flow involved is < 2100

Description : . A dilute aqueous solution is to be concentrated in an evaporator system. High pressure steam is available. Multiple effect evaporator system is employed, because (A) Total heat transfer area of ... in a single effect is much lower than that in any effect in a multi-effect system

Last Answer : (B) Total amount of vapor produced per Kg of feed steam in a multiple effect system is much higher than in a single effect

Description : Pick out the wrong statement. (A) Conversion of SO2 to SO3 in Monsanto-4 pass converter is about 98% (B) The chemical formula of oleum is H2S2O7 , which is formed by saturating ... but technical sulphuric acid (D) Decomposition of sulphuric acid on heating does not start before its boiling

Last Answer : (D) Decomposition of sulphuric acid on heating does not start before its boiling

Description : For small temperature difference, the heat transfer rate as per Newton's law of cooling is proportional to (where, Δt = excess temperature) (A) Δt (B) Δt 2 (C) Δt 3 (D) √(Δt)

Last Answer : (A) Δt

Description : A __________ evaporator employs an annular downtake. (A) Basket type (B) Horizontal (C) Long tube vertical (D) None of these

Last Answer : (A) Basket type

Description : Convective heat transfer co-efficient in case of fluid flowing in tubes is not affected by the tube length/diameter ratio, if the flow is in the __________ zone. (A) Laminar (B) Transition (C) Both 'a' & 'b' (D) Highly turbulent

Last Answer : (D) Highly turbulent

Description : Pick out the wrong statement. (A) Pasteurisation of milk involves moderate heating followed by cooling (B) Bakeries and breweries make use of yeasts (C) Enzyme is a complex nitrogenous compound (D) Oils and fats are alkaloids

Last Answer : (D) Oils and fats are alkaloids

Description : The rate of heat transfer from a vertical plate by natural convection depends upon the temperature differences (ΔT) between wall and outside bulk. The proportionality is given as (A) (ΔT) 1/4 (B) (ΔT) 1/2 (C) (ΔT) 5/4 (D) (ΔT) 3/4

Last Answer : (D) (ΔT) 3/4

Description : When vaporisation takes place directly at the heating surface, it is called (A) Film boiling (B) Nucleate boiling (C) Vapour binding (D) None of these

Last Answer : (B) Nucleate boiling

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it (A) Decreases the pressure drop (B) ... the outlet temperature of cooling medium (C) Increases the overall heat transfer coefficient (D) None of these

Last Answer : (C) Increases the overall heat transfer coefficient

Description : Overall heat transfer co-efficient for cooling of hydrocarbons by water is about (A) 50 -100 Kcal/hr.m2 .°C (B) 50 -100 W/m2 .°K (C) 50 -100 BTU/hr. ft. 2°F (D) 1000 - 1500 BTU/hr. ft. 2°F

Last Answer : (C) 50 -100 BTU/hr. ft. 2°F

Description : Pick out the wrong statement. (A) Orifice baffles are never used in a shell and tube heat exchanger (B) Pressure drop on the shell side of a heat exchanger depends upon tube pitch also

Last Answer : (A) Orifice baffles are never used in a shell and tube heat exchanger

Description : In an extended surface heat exchanger, fluid having lower co-efficient (A) Flows through the tube (B) Flows outside the tubes (C) Can flow either inside or outside the tubes (D) Should not be used as it gives very high pressure drop

Last Answer : (B) Flows outside the tubes

Description : In case of __________ boiling, the bubbles formed on a submerged hot surface get absorbed in the mass of the liquid. (A) Nucleate (B) Pool (C) Low pressure (D) None of these

Last Answer : (B) Pool

Description : A ______ is a specialized heat exchanger in which air and water are brought into direct contact with each otherin order to reduce the water's temperature. a. Cooling tower b. Heating tower c. Both d. All are wrong

Last Answer : cooling tower

Description : Pick up the incorrect statement from the following: (A) The rate of flow of water through a unit cross-sectional area under a unit hydraulic gradient, is called coefficient of permeability (B) ... aquifers, is governed by the Darcy's law (D) The term 'transmissibility' was introduced by Meinzer

Last Answer : Answer: Option D

Description : Log mean temperature difference (LMTD) cannot be used, if (A) Heat transfer co-efficient over the entire heat exchanger is not constant (B) There exists an unsteady state (C) The heat capacity is not constant and there is a phase change (D) None of these

Last Answer : (D) None of these

Description : Fouling factor for a heat exchanger is given by (where, U1 = heat transfer co-efficient of dirty surface U2 = heat transfer co-efficient of clean surface). (A) U1 - U2 (B) 1/U1 - 1/U2 (C) 1/U2 - 1/U1 (D) U2 - U1

Last Answer : (B) 1/U1 - 1/U2