Which of the following employs an accessory known as 'drift
eliminator'?
(A) Multiple effect evaporator
(B) Mechanical draft cooling tower
(C) Rotary dryer
(D) Rotating disc contacto
Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature
Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature
Description : Which furnace employs natural draft? (A) Coke oven (B) Boiler (C) Rotary kilns (D) L.D. converter
Last Answer : (A) Coke oven
Description : Design of hyperbolic cooling tower standard for all cooling tower a) Mechanical draft b) Natural draft c) Both a & b d) Neither a & b
Last Answer : b) Natural draft
Description : Which one of the following the maximum effect on cooling tower performance A Fill media B Drift C Lourvers D Casing
Last Answer : A Fill media
Description : Make up water is required in a cooling tower to replace the water lost by (A) Evaporation (B) Drift (C) Blowdown and leakage (D) All (A), (B) and (C)
Last Answer : (D) All (A), (B) and (C)
Description : Drift in a cooling tower is (A) The water entrained by the circulating air (B) Dependent on the water lost by evaporation (C) Desirable (D) All (A), (B) & (C)
Last Answer : (A) The water entrained by the circulating air
Description : The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is (A) Natural draft cooling tower (B) Induced draft cooling tower (C) Spray chamber (D) None of these
Last Answer : (C) Spray chamber
Description : When the temperature and humidity of air is low, we usually use __________ draft cooling tower. (A) Natural (B) Forced (C) Induced (D) None of these
Last Answer : (A) Natural
Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)
Last Answer : (C) Both (A) & (B)
Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature
Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column
Description : Use of natural draft cooling tower is practised, when the air has low (A) Humidity (B) Temperature (C) Both 'a' & 'b' (D) Neither 'a' nor 'b'
Last Answer : (C) Both 'a' & 'b
Description : The most efficient cooling tower out of the following is (A) Induced draft (B) Forced draft (C) Natural draft (D) Atmospheric
Last Answer : (A) Induced draft
Description : A natural draft cooling tower is filled with wooden grids, which covers about __________ percent of the tower height. (A) 10-15 (B) 30-40 (C) 70-80 (D) 90-100
Last Answer : (A) 10-15
Description : is the mechanical manipulation of soil to provide favorable condition for crop production. A. Power tiller C. Rotary tiller B. Tillage D. Disc plough
Last Answer : Tillage
Description : What Are The Advantages Of Induced Draft Cooling Tower Over Forced Draft Cooling Tower?
Last Answer : 1. The outlet water comes in contact with the driest air and warmest water comes in contact with most humid air. 2. The re-circulation is seldom a problem. 3. The first cost is low due to the reduction in pump power consumption.
Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above
Last Answer : reinforced concrete
Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above
Last Answer : Fan
Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above
Last Answer : Difference in air pressure
Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station
Last Answer : Power station
Description : Natural draft in hyperbolic cooling tower is used for production of a) Fertilizer b) Steel c) Chemical d) Electrical energy
Last Answer : d) Electrical energy
Description : Explain the construction and working of induced draft cooling tower with neat sketch.
Last Answer : Induced draft cooling tower : Diagram: Construction and working: Cooling towers are employed to cool utility cooling water by direct contact with air. The parts of a cooling tower are ... top pulls the hot air through the fills and cooled water gets collected in the cold water basin.
Description : How Mechanical Draft Cooling Towers Are Classified?
Last Answer : Mechanical draft cooling tower is classified into three types: 1. Forced draft tower. 2. Induced draft counterflow tower. 3. Induced draft cross flow tower.
Description : A __________ evaporator employs an annular downtake. (A) Basket type (B) Horizontal (C) Long tube vertical (D) None of these
Last Answer : (A) Basket type
Description : Paper industry employs __________ driers. (A) Cylinder (B) Rotary (C) Spray (D) Fluidised bed
Last Answer : (A) Cylinder
Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre
Last Answer : Propeller fans
Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower
Last Answer : Atmospheric cooling tower
Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower
Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower
Description : How is air produced in mechanical cooling tower 1 air fan 2 propeller fans 3 air blowers 4 propeller blowers
Last Answer : 2 propeller fans
Description : How is air produced in mechanical draught cooling tower? A] Air Tuyeres. B] Propeller fans C] Air blowers. D] Louvre
Last Answer : B] Propeller fans
Description : Tubes of multiple effect evaporator used for concentration of sugar cane juice are made of (A) Nickel (B) Copper (C) Stainless steel (D) Brass
Last Answer : (B) Copper
Description : . A dilute aqueous solution is to be concentrated in an evaporator system. High pressure steam is available. Multiple effect evaporator system is employed, because (A) Total heat transfer area of ... in a single effect is much lower than that in any effect in a multi-effect system
Last Answer : (B) Total amount of vapor produced per Kg of feed steam in a multiple effect system is much higher than in a single effect
Description : . In a backward feed multiple effect evaporator (A) Feed is introduced in the first effect (B) Feed flows from low pressure to high pressure (C) No pumps are required between successive effects (D) None of these
Last Answer : (B) Feed flows from low pressure to high pressure
Description : Vacuum is generally maintained in the vapour space of an evaporator mainly to (A) Get economical temperature difference by using moderate pressure steam (B) Facilitate forward ... (C) Concentrate heat sensitive materials (D) Achieve very high concentration of the final product
Last Answer : (A) Get economical temperature difference by using moderate pressure steam
Description : A backward feed multiple effect evaporator is better than forward feed for concentrating cold feed, because it provides (A) Higher economy (B) Lower capacity (C) Both (A) & (B) (D) Lower economy
Last Answer : (A) Higher economy
Description : For evaporation of viscous solution in a multiple effect evaporator, the preferred feeding scheme is (A) Forward (B) Backward (C) Parallel (D) None of these
Last Answer : (B) Backward
Description : Economy of a multiple effect evaporator is not influenced much by the (A) Boiling point elevations (B) Temperature of the feed (C) Rate of heat transfer (D) Ratio of the weight of the thin liquor to thick liquor
Last Answer : (A) Boiling point elevations
Description : A multiple effect evaporator has a capacity to process 4000 kg of solid caustic soda per day, when it is concentrating from 10% to 25% solids. The water evaporated in kg per day is (A) 6000 (B) 24000 (C) 60000 (D) 48000
Last Answer : (B) 24000
Description : Small scale evaporation is done in a (A) Heat exchanger (B) Condenser (C) Multiple effect evaporator (D) Steam jacketed kettle
Last Answer : (D) Steam jacketed kettle
Description : Black liquor generated during paper manufacture is concentrated in a (A) Single effect evaporator (B) Single effect evaporator followed by a crystalliser (C) Multiple effect evaporator (D) Multiple effect evaporators followed by a crystalliser
Last Answer : (C) Multiple effect evaporator
Description : In a multiple effect evaporator, the effect of boiling point elevation is to (A) Reduce the capacity (B) Reduce the economy (C) Increase the economy (D) None of these
Last Answer : (A) Reduce the capacity
Description : Economy of a multiple effect evaporator depends upon the (A) Heat balance consideration (B) Rate of heat transfer (C) Both (A) and (B) (D) Neither (A) nor (B
Last Answer : (A) Heat balance consideration
Description : Pick out the wrong statement. (A) Economy of a multiple effect evaporator is not influenced by the boiling point elevation (B) Two identical cubes of iron and copper will have the same heat ... in the field of refrigeration (D) Finned tube heat exchangers are suitable for heating air by steam
Last Answer : (B) Two identical cubes of iron and copper will have the same heat content under the same conditions of temperature
Description : In a forward feed multiple effect evaporator unit (A) Viscosity of liquid is highest in first effect (B) Transfer from effect to effect is done by pumps (C) No pump is required to withdraw the product from the last effect (D) None of these
Last Answer : (D) None of these
Description : A multiple effect evaporator as compared to a single effect evaporator of the same capacity has (A) Lower heat transfer area (B) Lower steam economy (C) Higher steam economy (D) Higher solute concentration in the product
Last Answer : (C) Higher steam economy
Description : In a forward feed multiple effect evaporator, the pressure is (A) Highest in last effect (B) Lowest in last effect (C) Same in all effects (D) Dependent on the number of effects
Last Answer : (B) Lowest in last effect
Description : Pick out the wrong statement. (A) The value of hydrostatic head increases with increase in vacuum in the effect in a multiple effect evaporator system (B) Entering velocity of the liquid in ... a multiple effect evaporation system, the number of effects is limited by the total boiling point rise
Last Answer : (C) Duhring's plot is used for calculating the concentration of solution
Description : Optimum number of effects in a multiple effect evaporator is decided by the (A) Cost benefit analysis (B) Floor area availability (C) Terminal parameters (D) Evaporation capacity required
Last Answer : (A) Cost benefit analysis