In synchronous motor, does the winding losses vary with load?


512 views

1 Answer

Answer :

No, in the synchronous motor the winding losses do not vary with load.

Like 0 like

Please log in or register to answer this question.

Related Questions


In a synchronous motor which losses varies with load?
Last Answer : In a synchronous motor, copper losses varies with load.

Show More

102 views 1 answer







Damper winding in a synchronous motor
Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Show More

87 views 1 answer








Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Show More

222 views 1 answer








Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Show More

257 views 1 answer







The damping winding in synchronous motor is generally used to?
Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Show More

157 views 1 answer







The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.
Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Show More

550 views 1 answer








Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Show More

195 views 1 answer







The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?
Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Show More

302 views 1 answer








Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

Show More

218 views 1 answer








Last Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Show More

116 views 1 answer







If the load of the normally excited synchronous motor is increased the power factor will?
Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Show More

150 views 1 answer







The synchronous motor which works on leading power factor and does not drive any mechanical load is called?
Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Show More

162 views 1 answer







The synchronous motor will develop maximum power when the load angle is?
Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Show More

223 views 1 answer







Damper winding is provided in 3 phase synchronous motors to :
Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Show More

93 views 1 answer







In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading
Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Show More

130 views 1 answer







In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle
Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Show More

340 views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

332 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

115 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

235 views 1 answer








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer








Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Show More

110 views 1 answer








Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Show More

83 views 1 answer







In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?
Last Answer : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

Show More

152 views 1 answer







A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be
Last Answer : Leading

Show More

564 views 2 answers








Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Show More

111 views 1 answer







The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu
Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Show More

98 views 1 answer








Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Show More

129 views 1 answer







Why synchronous motor Cannot start itself?

Show More

75 views 0 answers







How can we improve power factor using synchronous motor?

Show More

78 views 0 answers







What is the principle of synchronous motor?

Show More

74 views 0 answers







What is the use of synchronous motor?

Show More

68 views 0 answers







Why the speed of synchronous motor is constant?

Show More

67 views 0 answers








Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Show More

109 views 1 answer







what is the difference between synchronous and asynchronous motor?
Last Answer : Asynchronous motors and syncrouns motor are called as dc machines.  and also syncrouns motor called as induction motor. Asynonymous motor as are rotates with constant speed we not able to operate . ... It is able to operate. These are a small difference between syncrouns and asynchronous motors. 

Show More

260 views 2 answers







In DC motor iron losses are occurred in?
Last Answer : In DC motor iron losses are occurred in the armature.

Show More

138 views 1 answer








Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Show More

145 views 1 answer








Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Show More

72 views 1 answer







The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?
Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Show More

116 views 1 answer








Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Show More

877 views 1 answer








Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Show More

207 views 1 answer








Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Show More

100 views 1 answer







A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be
Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Show More

483 views 1 answer








Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Show More

142 views 1 answer








Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Show More

164 views 1 answer








Last Answer : The speed/load characteristics of a universal motor is same as that of D.C. series motor.

Show More

175 views 1 answer







List different starting methods of three phase synchronous motor. Explain any one of them.
Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Show More

157 views 1 answer







Draw and explain V and inverted V curves for synchronous motor.
Last Answer : V curves' and inverted V curves' for Synchronous Motor:  V curve:  V curve is a plot of the stator current versus field current for different constant loads. The graph is plotted ... Vcurves of synchronous motor. The highest point on each of these curves indicates unity power factor.

Show More

498 views 1 answer







List different torques in synchronous motor. 
Last Answer : Different Torques in Synchronous Motor: 1) Starting torque 2) Running torque 3) Pull-in torque 4) Pull-out torque

Show More

115 views 1 answer







In a self-controlled synchronous motor fed from a variable frequency inverter  (1) the rotor poles invariably have damper windings  (2) there are stability problems  (3) the speed of the rotor decides stator frequency  (4) the frequency of the stator decides the rotor speed
Last Answer : 2

Show More

637 views 2 answers








Last Answer : Slip-rings in a synchronous motor carry direct current.

Show More

99 views 1 answer






Show More⇦ PreviousNext ⇨