When two alternators are operating in parallel, the cause for circulating current is

(A) increase in the excitation of one machine

(B) increase in the driving torque of one machine

(C) reduction in angular velocity of one machine

(D) identical speed/load characteristics of both machines

1 Answer

Answer :

When two alternators are operating in parallel, the cause for circulating current is

(A) increase in the excitation of one machine

(B) increase in the driving torque of one machine

(C) reduction in angular velocity of one machine

(D) identical speed/load characteristics of both machines

Related questions

Description : Equalization of the power factors of two alternators operating in parallel is accomplished _____________. A. manually, by adjusting the governor controls B. automatically, by automatic voltage regulators ... the output of current transformers D. automatically, by the designed action of the governors

Last Answer : Answer: B

Description : The load sharing characteristics of two diesel alternators operating in parallel are directly related to the setting of their governors' ____________. A. load limit B. idle speed C. speed limit D. speed droop

Last Answer : Answer: D

Description : If the excitation is increased to one of two alternators operating in parallel, the _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. kilowatt load will be greatly increased D. ampere load will be greatly decreased

Last Answer : Answer: A

Description : To equalize the power factor of two alternators operating in parallel, the ____________. A. field excitation of both units is adjusted B. governors of both units are adjusted C. phase sequence is altered D. kilowatt load is evenly divided

Last Answer : Answer: A

Description : Two alternators rated are 200 KW at 4% regulation, 400 KW 5% regulation operating in parallel at 50HZ , when supply 600 KW the new frequency is a) 50 b) 49 c) 51.3 d) 47.7

Last Answer : Ans: 47.7

Description : If the excitation of an alternator operating in parallel with other alternators decreased, its: (1) Power factor becomes more leading (2) Output Kw will change (3) Power factor becomes more lagging (4) Power factor becomes unity

Last Answer : If the excitation of an alternator operating in parallel with other alternators decreased, its: Power factor becomes more leading

Description : Which of the following problems will occur if the circuit breaker of the incoming alternator is closed and it is 180° out of phase with the loaded alternator when paralleling? A. The rotor of the ... The rotor of the incoming alternator will stop. D. Both alternators will parallel 180° out of phase.

Last Answer : Answer: B

Description : Two paralleled alternators are operating near rated load. If one trips out mechanically, which of the listed actions should be taken FIRST? A. Restart the tripped machine immediately. B. Strip the board ... circuits. C. Start the emergency generator. D. Transfer all vital loads to the emergency bus.

Last Answer : Answer: B

Description : Which of the following statements is true concerning the operation of two alternators in parallel? A. The cycles per second of each alternator are the same. B. Both alternator governors must be set ... be the same on each alternator. D. The load must always be divided equally between alternators.

Last Answer : Answer: A

Description : After closing the circuit breaker to place two similar alternators in parallel, the NEXT step is to balance the _____________. A. power factor B. voltage load C. kilowatt load D. ampere load

Last Answer : Answer: C

Description : The KW load is evenly distributed between two alternators just placed in parallel by adjusting _____________. A. a balance coil B. the governor settings C. the field excitation D. a rheostat

Last Answer : Answer: B

Description : If the pointer of the synchroscope is rotating in the slow direction when you are preparing to parallel two alternators, the _____________. A. incoming machine is turning faster than the load alternator B ... alternator is ready to split D. incoming machine is beginning to pick up some of the load

Last Answer : Answer: B

Description : State the condition to be satisfied before connecting two alternators in parallel

Last Answer : The following are the three conditions to be satisfied by synchronizing the additional Alternator with the existing one or the common bus-bars. · The terminal voltage magnitude of the incoming ... incoming Alternator voltage must be the same as the bus-bar voltage. . Zero phase difference

Description : Handheld phase sequence indicators are useful when ________. A. preparing to parallel alternators B. connecting lighting branch circuits C. troubleshooting DC motors D. connecting shore power lines to the ship

Last Answer : Answer: D

Description : What is need of parallel operation of alternators?

Last Answer : 1. Optimum utilization of alternators as most of the power stations are interconnected by grid. 2. Reduced operating cost: number of alternators operating at a time can be changed depending on ... demands. 3. Easy maintenance: Alternator may be shut down for maintenance 4. Continuity and reliability

Description : What generator characteristics must be considered when alternators are synchronized for parallel operation?

Last Answer : Output voltage, frequency, and phase relationships.

Description : Why is this reverse power used instead of reverse current in alternators?

Last Answer : It is extremely difficult to detect reverse current with an alternating current system, reverse power can be detected and protection can be provided by reverse power relay.

Description : Alternators are preferred over dynamo because A. Alternators can produce a strong current of 30-40 amperes. B. Alternators don’t required cutout reiny C. Alternators don’t have commutaters D. All of the above

Last Answer : D. All of the above

Description : Why high impedance circulating current differential? 

Last Answer : Under through faults, CT’s of different phases saturates differently. Net spill current will operate low impedance CAG relay, so high impedance scheme with CAG relay and stabilising resistor used. 

Description : Besides a method of trial and error, which of the following methods is employed for solution of network problems in interconnected system ? (a) Circulating current method (b) Thevenin's theorem (c) Superposition of currents (d) Direct application of Kirehhoffs laws (e) All of the above

Last Answer : (e) All of the above

Description : Consider the following statements :  1. Salient pole alternators have small diameters and large axial lengths.  2. Cylindrical rotor alternators have a distributed winding.  3. Cylindrical rotor alternators are wound for large number ... 3 only (b) 2 and 4 only (c) 1 and 4 only (d) 2 and 3 only

Last Answer : Consider the following statements :  1. Salient pole alternators have small diameters and large axial lengths.  2. Cylindrical rotor alternators have a distributed winding.  3. Cylindrical rotor alternators are wound for ... 3 only (b) 2 and 4 only (c) 1 and 4 only (d) 2 and 3 only

Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.

Last Answer : Answer: C

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed

Last Answer : Answer: D

Description : An alternator operating in parallel begins to vibrate severely and eventually trips out on the reverse power relay. The cause of the vibration was a result of ______________________. A. the ... C. the alternator was operating out of synchronism D. flashover at the alternator collector rings

Last Answer : Answer: C

Description : A change in field excitation of an alternator operating in parallel will cause a change in its _____________. A. alternator frequency B. kilowatt load C. voltage output D. all of the above

Last Answer : Answer: C

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : Severe vibration, accompanied by flashover at the collector rings of an alternator operating in parallel, is a symptom of _____________. A. reverse current motorization B. loss of synchronism C. destructive overspeeding D. reversed polarity

Last Answer : Answer: B

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : Which is a function of the voltage regulators used with AC generators? A. To cut out generators when they are no longer required. B. To cut in additional generators automatically as ... between generators operating in parallel. D. To divide reactive current between generators operating in parallel.

Last Answer : Answer: D

Description : Pick out the wrong statement (A) Co-current absorbers are usually used, when the gas to be dissolved in the liquid is a pure substance (B) In case of gas absorption, HETP is ... reaction (D) In actual practice, absorption is an endothermic process, while stripping is an exothermic process

Last Answer : (D) In actual practice, absorption is an endothermic process, while stripping is an exothermic process

Description : For stripping of a gas in a counter current stripper, the operating line (A) Lies above the equilibrium curve (B) Lies below the equilibrium curve (C) Can lie above or below the equilibrium curve (D) Is always parallel to the equilibrium curve

Last Answer : (C) Can lie above or below the equilibrium curve

Description : The graph shown in the illustration represents the speed droop curves of two equal capacity alternators about to be paralleled. When paralleled, the greater portion of the total load above 60% for each unit will be picked up ... unit 'A' B. by unit 'B' C. equally by each unit D. none of the above

Last Answer : Answer: A

Description : Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators? A. This allows the oncoming machine to ... line. C. The reverse power relay is prevented from activating. D. All of the above.

Last Answer : Answer: D

Description : When paralleling two alternators, the synchronizing lamps remain lit as the synchroscope pointer approaches the 0°. This indicates the _____________. A. incoming alternator is running too fast B. alternator ... apart C. synchroscope is defective or broken D. alternator power factors are in phase

Last Answer : Answer: C

Description : When paralleling two alternators the synchronizing lamps grow dim and are totally darkened as the synchroscope pointer approaches the 0° position. This indicates the ____________. A. alternator voltages ... alternator is in phase with the bus voltage D. synchroscope pointer is defective or broken

Last Answer : Answer: C

Description : When paralleling two alternators using three synchronizing lamps, the flickering of all three lamps becomes progressively slower and slower. This means the ______________. A. frequency of the incoming ... the bus D. terminal voltage of the incoming alternator is approaching that of the bus

Last Answer : Answer: A

Description : You are paralleling two alternators. The synchronizing lamps grow dim and are totally darkened as the synchroscope pointer approaches the 0° position. This indicates that the ____________. A. alternator ... be closed C. incoming alternator is running too slowly D. synchroscope is defective or broken

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation of the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. type of alternator

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation to the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. number of field poles per alternator

Last Answer : Answer: B

Description : What are the two basic types of alternators?

Last Answer : Rotating armature and rotating field.

Description : The angular displacement between two interconnected stations is mainly due to (a) armature reactance of both alternators (b) reactance of the interconnector (c) synchronous reactance of both the alternators (d) all of the above

Last Answer : (a) armature reactance of both alternators

Description : Which ofthe following methods is used for air cooling of turbo-alternators ? (a) One sided axial ventilation (b) Two sided axial ventilation (c) Multiple inlet system (d) All ofthe above

Last Answer : (d) All ofthe above

Description : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The line voltage of the first machine is adjusted to ... will be  (A) 16.98 A (B) 29.41 A (C) 33.96 A (D) 58.82 A

Last Answer : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The ... instant they are paralleled. Under this condition, the synchronizing current per phase will be 16.98 A

Description : Why do cars use alternators instead of generators?

Last Answer : Cars don't use generators because the batery is already generating energy. They use alternators in order to convert the energy generated into a usable form.

Description : Automotive Alternators ?

Last Answer : form_title= Automotive Alternators form_header= Ensure you car will run with an alternator. How old is your current alternator?*= _ [50] How long have you owned your vehicle?*= _ [50] When was the last time you had you car in for a tune-up?*= _ [50]

Description : Which of the following devices are protected from being motorized by a reversepower relay? A. Alternators B. Wave guides C. Exciters D. Amplidynes

Last Answer : Answer: A

Description : Which of the following statements is true concerning all three-phase alternators? A. Each has three separate but identical armature windings acted on by one system of rotating magnets. B. Each has one ... The three phases always provide power to the load through three sets of slip rings and brushes.

Last Answer : Answer: A

Description : What Are The Various Types Of Rotors Used In The Alternators?

Last Answer : Salient pole rotor Non- salient pole rotor and Cylindrical rotor