With which of the following, a circuit breaker must be equipped for remote operation ?
(a) Inverse time trip
(b) Time-delay trip
(c) Shunt trip 
(d) None of the above
(e) All of the above

1 Answer

Answer :

With which of the following, a circuit breaker must be equipped for remote operation ?
(a) Inverse time trip
(b) Time-delay trip
(c) Shunt trip 
(d) None of the above
(e) All of the above

Related questions

Description : With which of the following, a circuit breaker must be equipped for remote operation ? (a) Inverse time trip (b) Time-delay trip (c) Shunt trip (d) None of the above (e) All of the above

Last Answer : (c) Shunt trip

Description : The number of cycles in which a high speed circuit breaker can complete its operation is  (A) 3 to 8 (B) 10 to 18 (C) 20 to 30 (D) 40 to 50

Last Answer : The number of cycles in which a high speed circuit breaker can complete its operation is 3 to 8

Description : Describe the construction of SF6 circuit breaker with neat diagram.

Last Answer : Construction of SF6 Circuit Breaker : A sulphur hexafluoride (SF6) circuit breaker consists of fixed and moving contacts enclosed in a chamber. The chamber is called arc interruption ... contact, moving contact and arcing horn are coated with a copper-tungsten arc-resistant material. 

Description : Define the following terms related to circuit breaker. 1) Breaking Capacity 2) Making Capacity 3) Short time rating and 4) Normal current rating

Last Answer : 1) Breaking Capacity: It is current (r.m.s) that a circuit breaker is capable of breaking at given recovery voltage under specified conditions (e.g. power factor, rate of rise of ... under specified conditions. The only limitation in this case is the temperature rise of current-carrying parts.

Description : Explain construction and working of SF6 circuit breaker.

Last Answer : Construction: A sulphur hexafluoride (SF6) circuit breaker consists of fixed and moving contacts enclosed in a chamber. The chamber is called arc interruption chamber, which contains the ... arc being extinguished. Finally the gas enters the contact space increasing the dielectric strength.

Description : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6

Last Answer : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6

Description : Earth Leakage circuit breaker (ELCB) works on the basis of

Last Answer : Earth Leakage circuit breaker (ELCB) works on the basis of Residual current

Description : Making capacity of the circuit breaker depends on (A) operating voltage (B) short circuit MVA (C) fault current (D) All of the above

Last Answer : Making capacity of the circuit breaker depends on (A) operating voltage (B) short circuit MVA (C) fault current (D) All of the above

Description : The arc temperature in Oil Circuit Breaker may reach up to_______.  (A) 5,000° K (B) 8,000° K (C) 10,000° K (D) None of the above

Last Answer : The arc temperature in Oil Circuit Breaker may reach up to 5,000° K 

Description : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Last Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Description : The Minimum Oil Circuit Breaker (MOCB) is named because of :  (A) Reduced requirement of oil (B) Reduced requirement of air (C) All of the above (D) None of the above

Last Answer : The Minimum Oil Circuit Breaker (MOCB) is named because of : Reduced requirement of oil 

Description : For selecting a circuit breaker, ______ should be determined.  (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Last Answer : For selecting a circuit breaker, ______ should be determined. (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Description : ln a minimum oil circuit breaker the oil is used

Last Answer : ln a minimum oil circuit breaker the oil is used to act as circuit breaking medium only

Last Answer : Arc in a circuit breaker is interrupted at zero current.

Last Answer : The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.

Last Answer : In a circuit breaker the basic problem is to transmit large power.

Last Answer : Ionization in circuit breaker is facilitated by high temperature, increase of mean free path, increasing field strength.

Last Answer : The voltage appearing across the contacts after opening of the circuit breaker is called recovery voltage.

Last Answer : Air blast circuit breaker is used for repeated duty.

Last Answer : Magnetic circuit breaker has instantaneous trip action.

Last Answer : Thermal circuit breaker has delayed trip action.

Last Answer : The arcing contacts in a circuit breaker are made of copper tungsten alloy.

Description : what is SF6 circuit breaker?

Last Answer : SF6 is Sulpher hexa Fluoride gas. If this gas is used as arc quenching medium in a Circuit breaker means SF6 CB.

Description : A vessel is equipped with two ship's service generators. Generator #1 is rated at 900 kw and generator #2 is rated at 600 kw. During parallel operation, with a hotel load of 1,000 kw, what should be the kw load on generator #2? A. 100 kw B. 400 kw C. 500 kw D. 600 kw

Last Answer : Answer: B

Description : In the illustration, the contacts between terminals 26 and 27 should be closed when _________. EL-0046 A. using one generator in isochronous mode only B. using two or more generators in ... through varying loads in parallel or single operation D. the circuit breaker is closed for that generator

Last Answer : Answer: C

Description : For an Resistive Load and Inductive load considered for switching operation of circuit breaker, Switching of which load is difficult and Why?

Last Answer : In case of switching resistive load, current and voltage will be in phase i.e,when during current zero voltage also will be zero in case of resistive load. Hence the voltage at the ... maximum. This results in re-striking of arc once again. Therefore switching inductive load will be difficult

Description : Sequence of operation of isolator and circuit breaker while opening and closing

Last Answer : Sequence of operation of Isolator and C.B while opening & closing is as below:  While Opening:   1. Open circuit breaker  2. Open Isolator  3. Close earthing switch  While Closing:  ... breaker is open  2. Open earthing switch  3. Close isolator  4. Close circuit breaker

Description : What is the single most important skill one must be equipped with before graduating from high school?

Last Answer : Social Skills. Meaning manners dealing with table manners and conversational manners. That is one of the most important things that will help you succeed in most jobs.

Description : A three-phase electrical system is equipped with ground detecting lamps. If one of the lamp goes dark and the other two burn normally before and after the test switch is operated, this indicates _______________. ... of the three phases D. the voltage to the dark lamp is less than that of the system

Last Answer : Answer: A

Description : After an accident, the operator of an aeroplane equipped with a flight recorder must keep the original recordings for a minimum period of: a. 30 days b. 90 days c. 45 days d. 60 days

Last Answer : d. 60 days

Description : Which of the following actions must be carried out prior to closing the alternator circuit breaker according to the graph shown in the illustration? EL-0002 A. Increase the alternator voltage. B. Decrease the line voltage. C. Increase the line voltage. D. Decrease the line frequency.

Last Answer : Answer: A

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : A circuit breaker differs from a fuse in that a circuit breaker _____________. A. melts and must be replaced B. is enclosed in a tube of insulating material with metal ferrules at each end C. gives no visual indication of having opened the circuit D. trips to break the circuit and may be reset

Last Answer : Answer: D

Description : Before touching a small capacitor connected to a de-energized circuit, or even one that is completely disconnected, you should ____________. A. gently tap the body with a screwdriver B. tag it ... insulated fuse puller D. short circuit the terminals to make sure that the capacitor is discharged

Last Answer : Answer: D

Description : With the help of neat diagram, explain operation of static relay.

Last Answer : Operation of Static Relay: Operation: 1) The solid-state component used are transistors, diodes, resistors, IC s, capacitor etc. The function of comparison and measurement are accomplished by ... ) An auxiliary dc supply is provided for operation of static relay elements as shown in figure.

Description : Describe the construction and Operation of Buchholz relay with neat labeled diagram.

Last Answer : Construction of Buchholz Relay: It takes the form of a domed vessel placed in the connecting pipe between the main tank and the conservator. The device has two elements. The upper element ... manner that it senses the sudden violent movement of oil/gas from transformer tank to conservator. 

Description : Describe the operation of current differential relay with neat sketch.

Last Answer : Operation of Current Differential Relay: Figure shows an arrangement of an overcurrent relay connected to operate as a differential relay for alternator protection under fault conditon. ... current flows through relay coil, causing relay to operate for protection of alternator winding.

Description : With neat diagram explain the operation of Horizontal break isolator.

Last Answer : Operation of Horizontal Break Isolator: 1) Fixed female contacts of metal are supported on stack of insulator. 2) Male contact rod is connected to central insulating support which can be ... on galvanized steel channel or steel frame. The moving male contact can be move through 90o.

Description : Explain operation of balanced beam type relay.

Last Answer : Balanced Beam Type Relay: Under normal operating condition the current through relay coil is such that the beam is held in the horizontal position by the spring. When the fault occurs on the system the ... becomes greater than pick-up value and beam is attracted to close the trip circuit. 

Description : Explain operation of µP based relay with block diagram

Last Answer : Operation of Microprocessor (µP) based relay: The inputs from the power system through CTs and PTS are received by the analog Input receiver; they are sampled simultaneously or ... compares the dynamic inputs and decides accordingly to generate trip/alarm signal to the output device.

Description : Explain construction and operation of induction type directional over current relay.

Last Answer : Directional overcurrent relay: Construction: It consists of two units: i) Non-directional Over-current unit ii) Directional power unit The directional unit consists of upper electromagnet ... closes the trip circuit. This operates circuit breaker which isolates the faulty section. 

Description : The operation of the relay which is most affected due to arc resistance is A) Mho relay B) Reactance relay C) Impedance relay D) All are equally affected

Last Answer : The operation of the relay which is most affected due to arc resistance is Mho relay

Description : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  (1) second harmonic current  (2) third harmonic current  (3) fifth harmonic current  (4) seventh harmonic current

Last Answer : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  second harmonic current 

Description : A remote batch-processing operation in which data is solely input to a central computer would require a. telegraphp line b. simplex lines c. mixed bad channel d. all of above

Last Answer : simplex lines

Description : A remote batch-processing operation in which datais solely input toa central computer would requirea: A. telegraphline B. simplex lines C. mixed-band channel D. All the above E. None of the above

Last Answer : simplex lines

Description : In accordance with Coast Guard Regulations (46 CFR), a steering gear feeder circuit from the emergency switchboard or alternate power supply must have the capacity for continuous operation of the rudder 15° side to side in not more than 60 seconds for a A. 1/4 hour B. 1/2 hour C. 1 hour D. 2 hours

Last Answer : Answer: B

Description : Electrical contact materials used in switches, brushes and relays must possess   (A) high thermal conductivity and high melting point  (B) Low thermal conductivity and low melting point   (C) High thermal conductivity and low melting point  (D) Low thermal conductivity and high melting point.