What are the losses in a power transformer and mention how these losses can be minimised?

1 Answer

Answer :

There are two losses in a transformer.

a. Iron losses.

b. Copper losses.

Iron losses – Iron losses constitutes of two losses.

a. Eddy current losses, these are due to the induced emf in the core, which constitutes a current in the core. These will heats up the core.

Eddy current losses can be minimised by using laminated core immersed in varnish. This provides a high resistance between the laminations and thus eddy current in reduced.

b. Hysterisis losses, these are due to the magnetic reversal of current by which there is friction between molecules of core and heat is generated.

Hysterisis losses can be minimised by selecting proper magnetic material, like silicon steel.

Copper losses – these losses are due to the resistance of the winding, which is equal to I2 rt (calories). These losses are depends on load. That is the losses are increased to the square of the load current

I – current through winding.

r – resistance of winding.

t – time duration. 

Related questions

Description : Stack heat losses can be minimised by (A) Controlling the excess air (B) Oxygen enrichment of combustion air (C) Using low c.v. fuels (D) Maintaining proper draft in the furnace

Last Answer : (A) Controlling the excess air

Description : . A special type of liquid transporting device is the diffuser pump, in which __________ are minimised. (A) Bearing losses (B) Disk friction (C) Shock losses (D) Cavitation

Last Answer : (C) Shock losses

Description : What are the transformer losses?

Last Answer : Answer: TRANSFORMER LOSSES - There are mainly two kinds of losses in a transformer namely 1. Copper loss (ohmic loss) and 2.magnetic loss (core loss). Copper losses are caused by the ... ohmic loss the following two losses are also present in the transformer stray load loss and dielectric loss.

Description : Explain about the losses in Transformer?

Last Answer : TRANSFORMER LOSSES - Transformer losses have two sourcescopper loss and magnetic loss. Copper losses are caused by the resistance of the wire (I2R). Magnetic losses are caused by eddy currents ... current. Eddy-current loss, however, is different for each frequency passed through the transformer.

Description : Why are iron losses considered as constant losses in transformer?

Last Answer : Iron losses depend on supply frequency and flux density in the core. For all normal operations, the frequency of flux reversals which is same as supply frequency is constant and the value of flux density ... . Hence iron losses remain constant under all load conditions. i-e from no-load to full-load

Description : What are the losses in transformer?

Last Answer : In transformer there are losses due to, 1. Resistance of the winding (copper losses). 2. Eddy current and Hysterisis in the iron parts and core (core and iron losses) 3. Losses due to leakage reactance ... cosiderable manner. Copper losses are variable and can be calculated by Ip 2 *rp and Is 2 *rs.

Description : Explain different losses in a transformer.

Last Answer : There are two types of losses occurring in transformer: Constant losses or Iron losses: The losses that occur in the core are known as core losses or iron losses. Two types of iron ... upon the loading conditions of the transformers. Therefore, these losses are also called as variable losses.

Description : A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz supply with secondary winding open circuited. Then (A) Both eddy current and hysteresis losses decreases. (B) Both ... same but hysteresis loss increases. (D) Eddy current loss increases but hysteresis loss remains the same.

Last Answer : (A) Both eddy current and hysteresis losses decreases.

Description : The efficiency of a transformer is mainly dependent on (A) core losses. (B) copper losses. (C) stray losses. (D) dielectric losses.

Last Answer : Ans: A Core loss has prominent value over other losses

Description : Mention the short comings of Merz Price scheme of protection applied to a power transformer.

Last Answer : In a power transformer, currents in the primary and secondary are to be compared. As these two currents are usually different, the use of identical transformers will give differential current, and ... turn-ratio are used, the differential current may flow through the relay under normal condition.

Description : Mention the important parts of a power transformer and their purposes. 

Last Answer : Conservator: This allows for shrinkage and swelling of transformer oil. When the oil is heated up it swells and rises to the conservator. When cools down it goes back to main tank. Conservator reduces sludge ... put. There are two types of tap changer. Online tap changer and off line tap changer.  

Description : Name the three power losses in a transformer

Last Answer : Copper-loss, eddy-current loss, and hysteresis loss

Description : How do you minimised strategic misrepresentation?

Last Answer : Need answer

Description : In a moderately sized packed absorption tower, channelling (which is most severe with stacked packings) can be minimised by taking the ratio of tower diameter to packing diameter (A) > 4 :1 (B) < 8 : 1 (C) > 8:1 (D) < 6:1

Last Answer : (C) > 8:1

Description : From the surface of reservoir, evaporation may be minimised by sprinkling (A) Spirit (B) Hydrochloric acid (C) Acetyl alcohol (D) Methane

Last Answer : (C) Acetyl alcohol

Description : Pick up the correct statement from the following: (A) Spherical aberration may be reduced by diminishing the aperture (B) Spherical aberration may be minimised by replacing the single lens by a ... telescope objectives, a combination of convex lens and concave lens is used (D) All the above

Last Answer : (D) All the above

Description : Pick up the correct statement from the following: (A) The cost of square rooms is less (B) The expenditure on the foundation and roof for the double storeyed building is nearly half of that ... cost of construction of a house may be minimised by restricting the height floors (D) All the above

Last Answer : Answer: Option D

Description : In the construction of a full veneer gold crown, future recession of gingival tissue can be prevented or at least minimised by, A. Extension of the crown 1 mm under the gingival crevice B. ... of the crown D. Slight under contouring of the tooth in the gingival one fifth of the crown

Last Answer : B. Reproduction of normal tooth incline in the gingival one third of the crown

Description : Variation in the drop size of seed can be minimised by (a) Using a short, smooth, small diameter tube with the discharge end close to bottom of furrow. (b) Discharging the seed directly from ... (c) Mechanically transferring the seeds from the metering unit in the furrow. (d) All of the above.

Last Answer : d) All of the above.

Description : Constant physical agitation of the spray liquid during field operations can be minimised by adding a). Emulsifiers b). Coupling agents c). Surfactants d). Humicants

Last Answer : a). Emulsifiers

Description : The following adverse effect of levodopa is not minimised by combining it with carbidopa: A. Involuntary movements B. Nausea and vomiting C. Cardiac arrhythmia D. ‘On-off ’ effect

Last Answer : A. Involuntary movements

Description : Risk of neural tube defect in the offspring can be minimised in pregnant women receiving antiepileptic drugs by supplemental therapy with: A. Folic acid B. Vitamin A C. Vitamin E D. Pyridoxine

Last Answer : B. Vitamin A

Description : Insulin resistance can be minimised by the use of: A. Corticosteroids B. Tolbutamide C. Protamine D. Monocomponent/human insulin

Last Answer : D. Monocomponent/human insulin

Description : State the meaning of skin effect and how can it be minimised. 

Last Answer : Meaning of skin effect :  When alternating current flows through conductor it has tendency to flow away from center of conductor. i.e. maximum current density is near skin of conductor and goes on ... whenever possible as Skin effect is absent (Since frequency 0) instead of A.C. supply.  

Description : Mention the properties of transformer oil.

Last Answer : Properties of transformer oil are, a) Colour – pale yellow. b) Moisture content -

Description : Why is it desirable to operate paralleled AC generators at the same power factor? A. Circulating currents are kept to a minimum. B. Field excitation losses are kept to a minimum. C. Generator ... will have a lesser tendency to hunt. D. Because a power factor increase will decrease kilowatt output.

Last Answer : Answer: A

Description : The purpose of amortisseur windings in a synchronous motor is to ______________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : Amortisseur windings are installed in a synchronous motor to _____________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : What are the major losses in nuclear power generating system? 

Last Answer : Condenser - 500 MW. Moderator - 40 MW. C/V and E/S system - 3.7 MW. 

Description : A 3-phase 50HZ SCIM takes a power input of 30 KW at its full load speed of 1440 rpm. Total stator losses are 1 KW. The slip and rotor ohmic losses at full load are a) 0.02, 600 W b) 0.04, 580 W c) 0.04, 1160 W d) 0.04, 1200 W

Last Answer : Ans: 0.04, 1160 W

Description : 72 Harmonics in transformer result in A. Increased core losses B. Increased I2R losses C. Magnetic interference with communication circuits D. All of the above

Last Answer : D. All of the above

Description : 64)During the short-circuit test on a small transformer the frequency is increased from 50-200Hz. The copper losses will increase by a factor of A. 16 B. 4 C. 1 D. 1/4

Last Answer : A) 16

Description : [53] The iron loss of the transformer is negligible during short circuit test because A. The entire input is just sufficient to meet Cu losses only B. Flux produced is a small fraction of the normal flux C. Iron core becomes fully saturated D. Supply frequency is held constant

Last Answer : B. Flux produced is a small fraction of the normal flux

Description : 48.During light loads, the transformer efficiency is low because A. Secondary output is low B. Transformer losses are high C. Fixed loss is high in proportion to the output D. Cu loss is small

Last Answer : C. Fixed loss is high in proportion to the output

Description : 45 The function of conservator in a transformer is A. To protect against internal fault B. To reduce copper as well as core losses C. To cool the transformer oil D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Last Answer : D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Description : 43 The purpose of providing an iron core in a transformer is to A.Provide support to windings B. Reduce hysteresis loss C. decrease the reluctance of the magnetic path D. reduce eddy current losses

Last Answer : C. Decrease the reluctance of the magnetic path

Description : 42 The efficiency of a transformer will be maximum when A. copper losses = hysteresis losses B. Hysteresis losses = eddy current losses C. Eddy current losses = copper losses D. Copper losses = iron losses

Last Answer : D. Copper losses = iron losses

Description : 8 The transformer core is laminated to A. Reduce the copper losses B. Reduce the core losses C. Reduce the eddy current losses D. None of the above

Last Answer : C. Reduce the eddy current losses

Description : 13) In an ideal transformer A. windings have no resistance B. core has no losses C. core has infinite permeability D. all of the above

Last Answer : D. All of the above

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : 7 The main advantage of auto transformer over a two winding transformer is A. Hysteresis losses are reduced B. Saving in winding material C. Copper losses are negligible D. Eddy losses are totally eliminated

Last Answer : A) hysteresis losses is reduced

Description : Explain how technical losses can be reduced by use of energy efficient transformer in Transmission and Distribution system.

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : List the losses occurring in transformer.

Last Answer : (1) Iron losses: (a) Eddy current losses (b) Hysteresis losses (2) Copper losses

Description : A 500 kVA, 3-phase transformer has iron losses of 300 W and full load copper losses of 600 W. The percentage load at which the transformer is expected to have maximum efficiency is  (A) 50.0% (B) 70.7% (C) 141.4% (D) 200.0%

Last Answer : A 500 kVA, 3-phase transformer has iron losses of 300 W and full load copper losses of 600 W. The percentage load at which the transformer is expected to have maximum efficiency is 70.7%

Description : Which losses in a transformer varies significantly with load  a. Hysteresis losses b. Eddy current losses c. Copper losses d. Core losses 

Last Answer : Which losses in a transformer varies significantly with load Copper losses

Description : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are   (a) 32, 36 (b) 20, 36 (c) 25, 50 (d) 40, 80 

Last Answer : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are 20, 36

Description : Eddy current losses in transformer cores can be reduced by the use of  1. Solid cores  2. Laminated cores  3. Ferrites  Select the correct answer using the codes given below : (a) 2 and 3 only (b). 1 and 2 only (c) 1 and 3 only (d) 1, 2 and 3

Last Answer : Eddy current losses in transformer cores can be reduced by the use of  1. Solid cores  2. Laminated cores  3. Ferrites  Select the correct answer using the codes given below : (a) 2 and 3 only (b). 1 and 2 only (c) 1 and 3 only (d) 1, 2 and 3

Description :  A transformer has maximum efficiency at 3/4 full load. The ratio of its iron losses and full load copper loss is : -  a) 16/9 b) 4 / 3 c) 3/4 d) 9 /16

Last Answer :  A transformer has maximum efficiency at 3/4 full load. The ratio of its iron losses and full load copper loss is : -  9 /16

Description : Reduction in core losses and increase in permeability are obtained with transformer employing?

Last Answer : Reduction in core losses and increase in permeability are obtained with transformer employing core built-up of laminations of cold rolled grain oriented steel.