Write nameplate details of the main generator. 

1 Answer

Answer :

Type THW-235

kW 237700

kVA 264000

Voltage 16500 V

Amps 9240 A

Power factor 0.9 lag.

Field voltage 326 V

Field current 2755 A

Insulation Class-F

Speed 3000 rpm

50 Hz, 3, double star connection. 

Related questions

Description : Which of the listed procedures is the best way to tell if a motor has become overloaded? A. Measure the current flow and compare it with the motor full load current flow as shown on the nameplate. ... Watch for telltale signs of smoke coming from the motor. D. Periodic opening of the O/L relay coil

Last Answer : Answer: A

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : Can Transformers be Operated at Voltages other than Nameplate Voltages?

Last Answer : In some cases, transformers can be operated at voltages below the nameplate rated voltage. In NO case should a transformer be operated at a voltage in excess of its name- plate rating unless taps are ... 10 KVA, the reduced rating would be 5 KVA, or in direct proportion to the applied voltage.

Description : What is the nameplate rating of the transformer ?

Last Answer : : The rating of a transformer indicates its power carrying capacity. The amount of power that a transformer can transfer from the primary circuit to the secondary circuit is called the nameplate rating of that ... terms of volt amperes ( VA), kilovolt amperes ( KVA), or megavolt amperes ( MVA) .

Description : Which of the two synchro designation codes is indicated by 5DG on a synchro nameplate?

Last Answer : The Navy prestandard designation code.

Description : What does the code 26V-11TX4D mean on a synchro nameplate?

Last Answer : It is the third modification of a 26-volt 400-hertz (torque) synchro transmitter whose body diameter is between 1.01 and 1.10 inches

Description : Can transformers be operated at voltages other than nameplate voltages?

Last Answer : In some cases, transformers can be operated at voltages below the nameplate rated voltage. In NO case should a transformer be operated at a voltage in excess of its nameplate rating, unless taps are ... 10 kVA, the reduced rating would be 5 kVA, or in direct proportion to the applied voltage.

Description : The shipboard general alarm system must receive its main source of power from _____________. A. a storage battery B. the emergency generator C. an auxiliary generator D. the ship's service generator

Last Answer : Answer: A

Description : The source of emergency lighting and power at loss of normal ship's power on a cargo vessel should be obtained from the ______________. A. emergency generator supply to the emergency ... switchboard C. battery supply to the main switchboard D. turbogenerator supply to the emergency switchboard

Last Answer : Answer: A

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. keep the lube oil warm for quick starting B. prevent moisture from condensing in the ... is shutdown C. prevent the windings from becoming brittle D. prevent acidic pitting of the slip rings

Last Answer : Answer: B

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C

Description : The prime mover of an AC two pole main propulsion generator drives the generator at 3600 RPM. If the main propulsion motor has 80 poles, what will be the propeller speed? A. 45 RPM B. 80 RPM C. 90 RPM D. 180 RPM

Last Answer : Answer: C

Description : As shown in the illustration, the motor generator(M-G) set's three-phase motor drives the ______________. EL-0101 A. motor and the generator B. motor and the exciter C. generator and the exciter D. main field and the interpole field

Last Answer : Answer: C

Description : Undervoltage trips are frequently installed on switchboard circuit breakers to trip ____________. A. out generators in the event of severe arcing or sparking B. out generators when there is reversal of power ... , but continues to run D. out generators when there is low voltage in the main circuit

Last Answer : Answer: D

Description : The purpose of the reverse power relay, provided on a ship's service alternator panel, is to trip the circuit in the event of ______________. A. main circuit overload B. high power transfer C. generator overspeeding D. alternator motorization

Last Answer : Answer: D

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : As shown in the illustration, the M-G set's three-phase motor drives the ______________. EL-0101 A. motor and the generator B. motor and the exciter C. generator and the exciter D. main field and the interpole field

Last Answer : Answer: C

Description : Upon failure of the normal power supply, the emergency generator is placed on the line by the _____________. A. main bus tie feeder B. automatic bus transfer device C. line connection feeder D. power failure alarm bus

Last Answer : Answer: B

Description : The frequency of an AC generator is adjusted by means of the ____________. A. main alternator field rheostat B. exciter field rheostat C. prime mover governor control D. equalizing reactor

Last Answer : Answer: C

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. prevent the windings from becoming brittle B. prevent moisture from condensing in the windings during ... C. prevent acidic pitting of the slip rings D. keep the lube oil warm for quick starting

Last Answer : Answer: B

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : In a diesel electric plant, raising the generator's field excitation will cause the DC propulsion motor to ________. A. increase in speed B. decrease in speed C. affect generator speed only D. affect main motor speed if done in conjunction with higher generator engine speeds

Last Answer : Answer: A

Description : On a vessel with turbo-electric drive, which of the following conditions would indicate that the propulsion motor had dropped out of synchronization with the propulsion generator? A. Excessive ... Tripped main motor interlocks C. Overheated crosstie busses D. Closed contact in the field circuits

Last Answer : Answer: A

Description : Why main generator/UT is not provided with separate overfluxing protection?

Last Answer : Since GT is provided with overfluxing protection, it is adequate to protect main generator / UT also. Main generator can withstand higher degree of overfluxing. If a generator CB is used, separate overfluxing protection is essential for main generator. 

Description : Why the earthing transformer primary voltage is 16.5 kV rated in main generator even though actual voltage during the E/F is root 3 times less?

Last Answer : The transformer should not saturate during E/F otherwise it will cause ferroresonance with the GT winding capacitance. Dangerous O/V and neutral shifting will occur. During loss of load or field ... saturation. Saturation can also occur due to point on wave of application causing flux doubling. 

Description : Why 100% winding protection is felt essential for main generator stator E/F protection? (Used in NAPS onwards?)  

Last Answer : At MAPS 4% of winding is not protected. Earlier felt that the Electro magnetic stress due high external fault currents near 4% of neutral may not be high to cause E/F here. But now felt that the mechanical stress can leads to E/F. 

Description : What precautions should be taken while meggering main generator?

Last Answer : All PT’s are racked out. Earthing transformer grounding terminals disconnected. Barring gear shall be kept off. Stator water shall be drained fully and hot air blown through conductors. Generator flexible lines shall be disconnected to isolate GT/UT. 

Description : What are the working principles of generator main protections?

Last Answer : GENERATOR START UP PROTECTIONS SUPPLEMENTARY PROTECTION OF GENERATOR The generator is normally expected to run rated speed before excitation power is applied by closing the field breaker. ... position to ensure that the protection is inoperable when the machine is connected to grid.  

Description : How main generator protection grouped?

Last Answer : The various protections associated with the generator, Generator transformer and Unit transformer are connected to a trip unit through trip relays 86A, 86B and 86C. The protective levels of generator are in ... breaker. During Class C trip, the generator will come on House load mode of operation.  

Description : How main generator earthing is done?

Last Answer : Generator neutral earthing is done through transformer and earth fault current is limited through resistance, which is connected across the secondary of the transformer. Generator 16.5 kV earth fault current is isolated from 220 kV through GT. Only star point of the generator is grounded. 

Description : What is the purpose of back up impedance protection in main generator?  

Last Answer : Covers inter-phase faults both externals to the GT and in GT. This also covers partially faults inside generator, time delayed to coordinate with 230 kV-distance protection. 

Description : Why cannot we have cables instead of bus duct in main generator? 

Last Answer : Very large number of cables in parallel required problems of sealing the terminations. 

Description : Will main generator differential relay pick up for generator earth faults? 

Last Answer : No earth fault current limited to 5A, while differential setting is 10%. 

Description : When the hydrogen explosion will take place in main generator?

Last Answer : When hydrogen concentration in air is more than 4% and less than 74% causes the explosion.  

Description : What are main types of DC generator? 

Last Answer : Mainly there are three types. a. Series generator or series wound generator. b. Shunt generator or shunt wound generator. c. Compound generator. There are different types of compound generator. ... a. Under compound generator. b. Flat or level compound generator. c. Over compound generator. 

Description : Write critical speeds of turbine generator?  

Last Answer : Generator rotor 1st critical speed 1283 rpm 2nd critical speed 3600 rpm Combined turbine generator 1st critical speed 1938 rpm 2nd critical speed 2120 rpm 3rd critical speed 2385 rpm 4th critical speed 2837 rpm 

Description : Write details MCC construction. 

Last Answer : a) MCC are made up of sheet steel enclosure, indoor floor mounting and free standing, Dust and vermin proof, modular type and of double front and single front (X1, Y1). b) Degree of protection is IP 50 ... SRPH MCC are safety related and SB, TB, RAB, CWPH, DM Plant MCC's are non safety related. 

Description : Induction generator is self excited machine. a) True b) False

Last Answer : Ans: B

Description : Voltage build up in an isolated induction generator depends on A. Capacitor bank value B. Residual magnetism of the rotor iron C. Residual magnetism of the stator iron a) A, B b) A, B, C c) B d) A, C

Last Answer : Ans: A

Description : If the residual flux is absent in the rotor iron of the isolated induction generator, a) it will not run. b) it will run as induction motor c) it will burn the winding d) it will not affect the characteristic of the generator

Last Answer : Ans: A

Description : Induction generator a) can not work in isolation b) can work in isolation c) should work in parallel with synchronous generators d) any of the mentioned

Last Answer : Ans: C

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip

Last Answer : Answer: D

Description : An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that the emergency diesel generator engine shut down when _____________. A. lubricating oil pressure is lost B. the engine overspeeds dangerously C. fixed CO2 is released into the emergency diesel generator space D. all of the above

Last Answer : Answer: D