In measuring crosstalk using dBx unit the reference power is
A. 1 mW
B. 1 W
C. 1 pW
D. 6 mW

1 Answer

Answer :

C. 1 pW

Related questions

Description : What is the reference noise level? A. 10 pW B. 0 dBm C. 1mW D. -90 dBm

Last Answer : D. -90 dBm

Description : Noise that occurs via capacitive or inductive coupling in a cable. A. Crosstalk B. Quantizing noise C. Reference noise D. Tone interference

Last Answer : A. Crosstalk

Description : Noise reduction system used for film sound in movie A. dBx B. dolby C. dBa D. dBm

Last Answer : B. dolby

Description : Part of a microwave link can be approximated by free space conditions. The antenna gain are each 40 dB, the frequency is 10 GHz, and the path length is 80 km. Calculate the receive power for a transmitted power of 10 W? A. 0.871 μW B. 871 μW C. 0.871 mW D. 871 nW

Last Answer : A. 0.871 μW

Description : ECE Board Exam March 1996 The power of standard test tone is normally ____________. A. 1 dB B. 0 mW C. 1 mW D. 1 W

Last Answer : C. 1 mW

Description : Crosstalk due to incomplete suppression of sidebands or to intermodulation of two or more frequency-multiplexed channels which is unintelligible is classified as A. Impulse noise B. Thermal noise C. Quantizing noise D. Miscellaneous noise

Last Answer : D. Miscellaneous noise

Description : Sources of impulse noise induced in communication channels. A. Erroneous digital coding bit caused by an error on a transmission facility B. Transients due to relay operation C. Crosstalk from dc signaling systems D. All of these

Last Answer : D. All of these

Description : Noise occurring in the presence of signal resulting from a mismatch between the exact value of an analog signal and the closet available quantizing step in a digital coder. A. Quantizing noise B. Thermal noise C. Impulse noise D. Crosstalk

Last Answer : A. Quantizing noise

Description : A reading of -50 dBm on the disturbing pair, and -80 on the disturbed pair equals _____ dB of crosstalk coupling. A. 20 B. 30 C. 60 D. 25

Last Answer : B. 30

Description : Is the interference coming from other communications channels? A. Jitter B. Crosstalk C. RFI D. EMI

Last Answer : B. Crosstalk

Description : Which standard recommends crosstalk limits? A. CCIT G.152 B. CCIT G.150 C. CCIT G.151 D. CCIT G.161

Last Answer : C. CCIT G.151

Description : What is the term used in telephony and telegraphy for irregular disturbing radiation due to various causes and in a particular produced by arc transmitters causing a rushing sound in receiving telephones? A. Fax tone B. Mush C. Hiss D. Crosstalk

Last Answer : B. Mush

Description : An interfering current in a telegraph or signaling channel due to telegraph or signaling current by another channel. A. Crosstalk B. Noise current C. Crossfire D. Intermodulation

Last Answer : C. Crossfire

Description : ECE Board Exam March 1996 Crosstalk coupling is ___________. A. dBm (disturbing pair) minus dBm (disturbed pair) B. the difference between readings on a cable pair with a tone and a cable pair without ... a cable C. signals from one circuit that get into another circuit D. All of these are true

Last Answer : D. All of these are true

Description : ECE Board Exam November 1996 What is the applied power if a thermal RF wattmeter is connected to a transmitter through a variable attenuator? The wattmeter reads 84 mW when 15 dB of attenuation is used. A. 4.656 watts B. 2.656 watts C. 3.656 watts D. 2.856 watts

Last Answer : B. 2.656 watts

Description : ECE Board Exam November 1996 What is the applied power if a thermal RF wattmeter is connected to a transmitter through a variable attenuator? The wattmeter reads 84 mW when 15 dB of attenuation is used. A. 4.656 watts B. 2.656 watts C. 3.656 watts D. 2.856 watts

Last Answer : A. PAM

Description : The electrical power unit Giga Watt (GW) may be written as a) 1,000,000 MW b) 1,000 MW c) 1,000 kW d) 1,000,000 W

Last Answer : b) 1,000 MW

Description : You are measuring noise at a -6 dB level point, using the Lenkurt 601A, F1A weighting network, and a flat meter. The meter reading is -59 dBm. This is _________ dBa0. A. 24 B. 12 C. 23 D. 32

Last Answer : D. 32

Description : In acoustics, what is the reference pressure in lb/ft2 unit? A. 2x10-5 B. 0.0002 C. 2.089 D. 2.980

Last Answer : C. 2.089

Description : You are measuring noise at a +3 dB level point, using the Lenkurt 601A, F1A weighting network, and a flat meter. The meter reading is -57dBm. This is ________dBa0. A. 20 B. 15 C. 25 D. 17

Last Answer : C. 25

Description : Firefox (remmeber password or Master Pw feature) Safe from hackers?

Last Answer : answer:Unplug your phone cable. Done that? Now you're safe. It's unlikely that someone will specifically pick on you to get your password. But sure, if someone found your master password and had access to ... 't be that paranoid, surely, I hope all goes well though and that you never get hacked :)

Description : In the figure shown here, QS = SR, QU = SU, PW = WS and ST || RV. What is the value of -Maths 9th

Last Answer : answer:

Description : WXYZ is a square of side length 30. V is a point on XY and P is a point inside the square with PV perpendicular to XY. PW = PZ = PV – 5. Find PV. -Maths 9th

Last Answer : answer:

Description : What device measures rf power by measuring the heat the rf power generates? A. Calorimeter B. Goniometer C. Spectrum meter D. Oscilloscope

Last Answer : A. Calorimeter

Description : Power is __________. A. actual amount of power reference to 1mW B. logarithmic ratio of two powers C. definite amount of energy per time period D. current flow per time period

Last Answer : C. definite amount of energy per time period

Description : The difference between signal strength at a given point and a reference level is________. A. power B. dBm C. level D. ratio

Last Answer : C. level

Description : What does the noise weighting curve shows? A. Noise signals measured with a 144 handset B. Power levels of noise found in carrier systems C. The interfering effect of other frequencies in a voice ... a reference frequency of one kilohertz D. Interfering effects of signals compared with a 3-kHz tone

Last Answer : C. The interfering effect of other frequencies in a voice channel compared with a reference frequency of one kilohertz

Description : With conventional hydrogen cooling it is possible to increase the rating of a single unit to (a) 50 MW (b) 100 MW (c) 200 MW (d) none ofthe above

Last Answer : (c) 200 MW

Description : The output power of a filter is 100 mW, when the signal frequency is 6 kHz. When the frequency is increased to 25 kHz, the output power falls to 50 mW. What is the dB change in power ? (a) -3 dB (b) -5 dB (c) -7 dB (d) -2 dB

Last Answer : The output power of a filter is 100 mW, when the signal frequency is 6 kHz. When the frequency is increased to 25 kHz, the output power falls to 50 mW. What is the dB change in power ?  -3 dB 

Description : You are measuring noise in a voice channel with a Lenkurt 601A, F1A weighting network and a flat meter. Your meter reads -47dBm. What is this reading in dBa? A. 77 dBa B. 35 dBa C. 38 dBa D. 32 dBa

Last Answer : C. 38 dBa

Description : When measuring a transmitter’s frequency against a suitable standard, the frequency to be measured is taken from the A. oscillator stage B. intermediate amplifier C. buffer stage D. final RF stage

Last Answer : D. final RF stage

Description : The agreed standard for measuring loudness is the loudness sensation produced by a 1000 Hz sine wave _____ dB above the listener’s threshold of hearing. A. 80 B. 50 C. 30 D. 40

Last Answer : D. 40

Description : The use of telecommunication for automatic indicating or recording measurement at the distance from the measuring instrument. A. Monitoring B. Tracking C. Telemetry D. Telecommand

Last Answer : C. Telemetry

Description : ____________ is measuring the propagated field strength over the projected service area A. Radio sounding B. None of these C. Radio monitoring D. Radio survey

Last Answer : D. Radio survey

Description : You are measuring noise in a voice channel at 7 dB test point level. The meter reads -56 dBm (FIA weighted). What is the reading in dBrnc? A. 20 B. 32 C. 35 D. 25

Last Answer : C. 35

Description : You are measuring a voice channel at a -4 dB test point level, the meter reads -73 dBm (pure test tone) convert the reading in dBmCO. A. 16 B. 18 C. 22 D. 12

Last Answer : C. 22

Description : In measuring noise in a voice channel at a 4 dB test point level, the meter reads -70 dBm (F1A weighted), convert the reading to pWp. A. 53 B. 93 C. 63 D. 83

Last Answer : B. 93

Description : What is the effective radiated power of a repeater with 120 watts transmitter power output, 5 dB feedline loss, 4 dB duplexer and circulator loss, and 6 dB antenna gain? A. 601 W B. 240 W C. 60 W D. 379 W

Last Answer : C. 60 W

Description : What is the effective radiated power of a repeater with 75 watts transmitter power output, 5 dB feedline loss, 4 dB duplexer and circulator loss, and 6 dB antenna gain? A. 37.6 W B. 237 W C. 150 W D. 23.7 W

Last Answer : A. 37.6 W

Description : What is the effective radiated power of a repeater with 50 watts transmitter power output \, 4 dB feedline loss, 3 dB duplexer and circulator loss, and 6 dB antenna gain? A. 158 W B. 39.7 W C. 251 W D. 69.9 W

Last Answer : B. 39.7 W

Description : Phenomena in which signal transmitted in one circuit creates undesired effect in other circuit is known as A. crosstalk B. signal attenuation C. sampling D. crosslinking

Last Answer : crosslinking

Description : _______ is a typeof transmission impairment in which an outside sourcesuch as crosstalk corrupts asignal. A) Attenuation B) Distortion C) Noise D) Decibel

Last Answer : Noise

Description : Fiber-optic cables do not: a. carry current b. cause crosstalk c. generate EMI d. all of the above

Last Answer : d. all of the above

Description : A theoretical reference antenna that provides a comparison for antenna measurements. A. Marconi antenna B. Isotropic radiator C. Yagi-Uda array D. Whip antenna

Last Answer : B. Isotropic radiator

Description : The physical location of a satellite is determined by its A. distance from the earth B. latitude and longitude C. reference to the stars D. position relative to the sun

Last Answer : B. latitude and longitude

Description : What is the reference tone level for dBa? A. -90 dBm B. -82 dBm C. -67 dBm D. -85 dBm

Last Answer : D. -85 dBm

Description : What is the reference tone level for dBrn? A. -90 dBm B. -82 dBm C. -67 dBm D. -85 dBm

Last Answer : A. -90 dBm

Description : What is the reference level for noise measurement, F1A weighted? A. -90 dBm B. -82 dBm C. -67 dBm D. -85 dBm

Last Answer : D. -85 dBm

Description : Reference noise is ___________. A. a 1000 Hz, -90 dBm tone B. a noise that creates the same interfering effect as a 1000Hz, -90dBm tone C. a noise that creates zero dBrn in a voice channel D. B and C above

Last Answer : D. B and C above

Description : Standard design reference for environmental noise temperature. A. 300 K B. 290 K C. 32 ˚F D. 212˚F

Last Answer : B. 290 K