What are different types of circuit breakers employed in thermal power plant?

1 Answer

Answer :

Answer: For low voltage operation 415/220V vacuum circuit breakers or air break circuit breakers are employed. For voltage ratings about 6.6kV and beyond SF6 circuit breakers are employed.

Related questions

Description : What are different types of circuit breakers employed in thermal power plant?

Last Answer : For low voltage operation 415/220V vacuum circuit breakers or air break circuit breakers are employed. For voltage ratings about 6.6kV and beyond SF6 circuit breakers are employed.

Description : Protection against sustained overloads occurring in molded-case circuit breakers is provided by a/an __________. A. overvoltage release B. thermal acting trip C. thermal overload relay D. current overload relay

Last Answer : Answer: B

Description : State the different types of circuit breakers.

Last Answer : Air ,oil,vacuum circuit breakers.

Description : What are the different Generator Protections employed in Thermal Power Plants?

Last Answer : Answer: Faults in the windings, Over load protection, Over heating of windings or bearings, Over speed protection, Loss of Excitation protection, Motoring operation protection, Inadvertent ... , out of step operation protection, sub-synchronous oscillations protection and earth fault protection

Description : What are the different Generator Protections employed in Thermal Power Plants?

Last Answer : Faults in the windings, Over load protection, Over heating of windings or bearings, Over speed protection, Loss of Excitation protection, Motoring operation protection, Inadvertent energisation ... , out of step operation protection, sub-synchronous oscillations protection and earth fault protection

Description : Accidental grounds in a shipboard electrical system must be repaired as soon as possible as they will ____________. A. result in immediate power outages B. damage circuit breakers C. appear on the ground detection system D. damage insulation and may cause outages

Last Answer : Answer: D

Description : Undervoltage trips are frequently installed on switchboard circuit breakers to trip ____________. A. out generators in the event of severe arcing or sparking B. out generators when there is reversal of power ... , but continues to run D. out generators when there is low voltage in the main circuit

Last Answer : Answer: D

Description : The purpose of a main switchboard circuit breaker's reverse-power trip is to _____________. A. prevent main circuit overload B. protect the circuit breaker blowout coil C. prevent alternator motorization D. prevent low voltage tripout

Last Answer : Answer: C

Description : Why we need isolation transformers in power circuit ? why cant we use breakers to isolate?

Last Answer : In Isolation transformer is used, if there is change in parameter values of any side, the other side parameters will remain unchanged.

Description : A ground is indicated by the ground-detecting system on the main electrical switchboard. The FIRST step in locating the actual ground is to _____________. A. close all circuit breakers in ... ground detection system indicates normal C. change over generators D. check each circuit with a megohmmeter

Last Answer : Answer: B

Description : During maintenance of circuit breakers, _______________. A. always smooth roughened contact surfaces with a file B. never pass more than rated breaker current through the overload heater element C. ... wear and misalignment of main contacts D. assume heater elements installed are of correct size

Last Answer : Answer: C

Description : Periodic testing of circuit breakers is necessary to assure that a correctly rated and properly installed unit _________________. A. can trip faster as it increases in age B. will continue to provide ... not exceed its interrupting capacity D. be able to withstand at least 125% of applied voltage

Last Answer : Answer: B

Description : You can determine if a circuit breaker has tripped by ________________. A. examining the position of the handle B. checking for which of the breakers is warm C. looking for a burned-out link D. all of the above

Last Answer : Answer: A

Description : A 'dead front' switchboard is one _____________. A. without switches on it B. with insulated switches and no exposed terminals C. without circuit breakers D. without safety hand rails nor rubber mats

Last Answer : Answer: B

Description : The purpose of a short circuit forcing module (short time trip) installed in a branch line is to provide ____________. A. high speed clearance of low impedance short circuits in the branch B. ... C. isolation of short circuits by selective tripping of branch circuit breakers D. all of the above

Last Answer : Answer: D

Description : Why Isolation switches are provided along with the circuit breakers?

Last Answer : Isolation switches are provided for separating the disconnected element from the live portion of the system for the purpose of safety

Description : Air Blast Circuit Breakers Advantages Disadvantages

Last Answer : Air Blast Circuit Breakers Advantages Disadvantages In air blast circuit breakers, compressed air at a pressure of 20-30 kg/cm2 is employed as an arc quenching medium. Air blast circuit breakers ... air blast circuit breaker current chopping problem exists There is a problem of re-striking voltage

Description : How direct tests are conducted in circuit breakers?

Last Answer : Using a short circuit generator as the source. Using the power utility system or network as the source.

Description : Write the classifications of test conducted on circuit breakers.

Last Answer : Type test Routine test Reliability test Commissioning test

Description : Write the classification of circuit breakers based on the medium used for arc extinction?

Last Answer : Air break circuit breaker Oil circuit breaker Minimum oil circuit breaker Air blast circuit breaker SF6 circuit breaker Vacuum circuit breaker

Description : What are the protections provided in PMCC circuit breakers?

Last Answer : 1. IDMT O/C (CDG 34). 2. IDMT E/F (CDG 11).  3. Under voltage (40% of 110V). 

Description : Which of the device is employed in substation to limit the short circuit current in the power system: a) Shunt condenser b) Reactor c) Series capacitor d) Shunt capacitor

Last Answer : Ans: B

Description : Air blast circuit breakers for 400 kV power system are designed to operate in (a) 100 microsecond (b) 50 millisecond (c) 0.5 sec (d) 0.1 sec

Last Answer : (b) 50 millisecond

Description : . If the power distribution system shown in figure 2-22 uses selective tripping, what is the time delay rating for each of the circuit breakers shown?

Last Answer : CB1-long time delay; CB2, CB3-short time delay; CB4 through

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Description : What are different types of Steam boilers used in Thermal Power Plants?

Last Answer : Answer: Different type of boiler used in thermal power plants are: • Fire tube boiler • Water tube boiler • Natural Circulation boiler • Forced Circulation boiler • Once through boiler

Description : What are different types of Steam boilers used in Thermal Power Plants?

Last Answer : Different type of boiler used in thermal power plants are: Fire tube boiler Water tube boiler Natural Circulation boiler Forced Circulation boiler Once through boiler

Description : What is the significance of SF6 gas pressure in 6.6kV breakers?

Last Answer : Density gauge Green – correct SF6 pressure (3 –3.5bar) Yellow – pressure for breaking system fault current (refilling should be done) Red – SF6 pressure less than 2 bar, which indicates leak in the system. 

Description : What FCN was implemented to avoid reactor trip on 220V-DC failure of PHT and PPP breakers?

Last Answer : The breaker close position supervision relay VAA 21 is changed by VAJC type, contacts position do not change if 220V-DC is lost now.

Description : Why under voltage tripping of motor is incorporated in motor feeder breakers? 

Last Answer : The under voltage can occur in case of bus fault. If the motors are kept connected they will feed the fault which may cause the damage. Due to the back feeding from the motor the motor will slow down ... case pht motor will not rotate for the designed 3 minute period in case of bus under voltage).  

Description : What is the difference in action of lock out pressure signal on 6.6 kV and 220 kV breakers?

Last Answer : When lock out signal comes to 6.6 kV breakers the breaker will trip. Where as in case of 220 kV breakers the breaker will not trip. If the breaker is open it will be open only and can not be closed. If it is in closed condition it will be closed.

Description : What type breakers are provided in 6.6 kV buses?

Last Answer : ABB. Make, SF6 gas, 1250A and 2000A capacity circuit breakers are provided in 6.6 kV buses. 

Description : When I run more electrical appliances, the circuit breakers go out and I have to go "throw them". How to fix it? Call us electricians to put stronger circuit breakers? Or how is it handled?

Last Answer : calculate the power consumption of the appliances (current must be lower than the value of the circuit breaker (s)) the question is what appliances are involved (some, typically motors, need more ... "electricity", invite electricians and have specific options and needs explained "on the spot". ;-)

Description : When there's a storm outside and it hits the lead, will it help me that I have circuit breakers at home? Or what will burn in the drawer so?

Last Answer : the circuit breaker will not help, even the switched-off switch in the socket will not help, it may not burn out, but the electronics may be destroyed - even invisibly from the outside -

Description : Where are all the controls on most circuit breakers?

Last Answer : The only control on a circuit breaker is its on/off/reset leveror button.

Description : How do circuit breakers keep the wires in an electric circuit from overheating?

Last Answer : They reduce the flow of electrons.

Description : How do circuit breakers keep the wires in an electric circuit from overheating?

Last Answer : They reduce the flow of electrons.

Description : Are circuit breakers more expensive the better they are?

Last Answer : On one hand you don't want to search for the absolute cheapest circuit breaker you can find.On the other this is a competitive business and most circuit breakers have similar quality and price ranges

Description : In which of the following item(s), spring is used to store energy. (A) clocks (B) toys (C) circuit breakers (D) all of the above

Last Answer : (D) all of the above

Description : Which of the following circuit breakers has high reliability and minimum maintenance ? (a) Air blast circuit breakers (b) Circuit breaker with SF6 gas (c) Vacuum circuit breakers (d) Oil circuit breakers

Last Answer : (b) Circuit breaker with SF6 gas

Description : Insulation resistance of high voltage circuit breakers is more than (a) 1 mega ohms (b) 10 mega ohms (c) 100 mega ohms (d) 500 mega ohms

Last Answer : (c) 100 mega ohms

Description : The time of closing the cycle, in modern circuit breakers is (a) 0.003 sec (b) 0.001 sec (c) 0.01 sec (d) 0.10 sec (e) none of the above

Last Answer : (a) 0.003 sec

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by (a) lengthening of the gap (b) cooling and blast effect (c) both (a) and (b) (d) deionizing the oil with forced air (e) none of the above

Last Answer : (c) both (a) and (b)

Description : Circuit breakers are essentially (a) current carrying contacts called electrodes (b) arc extinguishers (c) circuits to break the system (d) transformers to isolate the two systems (e) any of the above

Last Answer : (a) current carrying contacts called electrodes

Description : Circuit breakers usually operate under (a) transient state of short-circuit current (b) sub-transient state of short-circuit current (c) steady state of short-circuit current (d) after D.C. component has ceased

Last Answer : (a) transient state of short-circuit current

Description : Fault diverters are basically (a) fuses (b) relays (c) fast switches (d) circuit breakers

Last Answer : (c) fast switches

Description : On which of the following routine tests are conducted ? (a) Oil circuit breakers (b) Air blast circuit breakers (c) Minimum oil circuit breakers (d) All of the above

Last Answer : (d) All of the above

Description : What are the three time delay ratings for circuit breakers?

Last Answer : Instantaneous, short time delay, and long time delay.