What is the significance of SF6 gas pressure in 6.6kV breakers?

1 Answer

Answer :

Density gauge

Green – correct SF6 pressure (3 –3.5bar)

Yellow – pressure for breaking system fault current (refilling should be done)

Red – SF6 pressure less than 2 bar, which indicates leak in the system. 

Related questions

Description : What are the levels of SF6 gas in 220 kV breaker and their significance?

Last Answer : 7 kg/cm2 - normal pressure 5.2 bar - alarm 5.0 bar - closing/tripping operation blocked. 

Description : Which of the following circuit breakers has high reliability and minimum maintenance ? (a) Air blast circuit breakers (b) Circuit breaker with SF6 gas (c) Vacuum circuit breakers (d) Oil circuit breakers

Last Answer : (b) Circuit breaker with SF6 gas

Description : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

Last Answer : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

Description : Why UT, SUT secondary is rated for 6.9kV where as bus voltage is 6.6kV? 

Last Answer : The no load secondary 6.9kV voltage level adequately takes into account voltage drop during loaded condition to cater station buses at 6.6kV level. 

Description : What are the characteristic of SF6 gas?

Last Answer : It has good dielectric strength and excellent arc quenching property. It is inert, non-toxic, noninflammable and heavy. At atmospheric pressure, its dielectric strength is 2.5 times that of air. At three times atmospheric pressure, its dielectric strength is equal to that of the transformer oil.

Description : What is meant by electro negativity of SF6 gas?

Last Answer : SF6 has high affinity for electrons. When a free electron comes and collides with a neutral gas molecule, the electron is absorbed by the neutral gas molecule and negative ion is formed. This is called as electro negativity of SF6 gas.

Description : What are the properties of SF6 gas?  

Last Answer : This is inert gas. Odorless, non-toxic, colourless, stable, non-inflammable and density is more hence high dielectric strength. The special property of this gas is Electro negativity. This gas ... more slow in conduction, so that resistance in medium is increases and get arc get extinguishes. 

Description : What are the properties of SF6 gas?  

Last Answer : Physical properties 1. Colourless 2. Odorless 3. Non-toxic. Pure SF6 gas is not harmful to the health. 4. Non-inflammable. 5. Density- more gas density, 5 times ... advantages offer increased safety, reduction in size, weight, noiseless operation, easy installation, handling and maintenance. 

Description : What is the difference in action of lock out pressure signal on 6.6 kV and 220 kV breakers?

Last Answer : When lock out signal comes to 6.6 kV breakers the breaker will trip. Where as in case of 220 kV breakers the breaker will not trip. If the breaker is open it will be open only and can not be closed. If it is in closed condition it will be closed.

Description : The operating voltage of high voltage cables is up to (a)l.lkV (b)3.3kV (c)6.6kV (d)llkV

Last Answer : (d)llkV

Description : at the terminal of a three-phase 6.6Kv alternator a load R=200 ohm is connected between two-phase and the third phase is opened. Z1=z2=5 ohm Zo=2 find out the fault current .

Last Answer : 32A

Description : What Is Sf6 Circuit Breaker?

Last Answer : SF6 is Sulpher hexa Flouride gas.. if this gas is used as arc quenching medium in a Circuitbreaker me SF6 CB.

Description : What is the purpose of compressed air in SF6 breaker?

Last Answer : This used for drive for opening and closing of the contacts. (Arc quenching is taken care by SF6 gas) 

Description : For interrupting capacitive currents which Circuit Breaker (CB) is used a) SF6 CB b) Oil CB c) Vacuum CB d) Air blast CB

Last Answer : Ans: Vacuum CB

Description : What type breakers are provided in 6.6 kV buses?

Last Answer : ABB. Make, SF6 gas, 1250A and 2000A capacity circuit breakers are provided in 6.6 kV buses. 

Description : SF6 gas (a) is yellow in colour (b) is lighter than air (c) is nontoxic (d) has pungent small (e) none of the above

Last Answer : (c) is nontoxic

Description : Which of the following is not a greenhouse gas ? a) CFCs b) SO2 c) PFC d) SF6

Last Answer : b) SO2

Last Answer : SF6 gas is nontoxic.

Description : Accidental grounds in a shipboard electrical system must be repaired as soon as possible as they will ____________. A. result in immediate power outages B. damage circuit breakers C. appear on the ground detection system D. damage insulation and may cause outages

Last Answer : Answer: D

Description : A ground is indicated by the ground-detecting system on the main electrical switchboard. The FIRST step in locating the actual ground is to _____________. A. close all circuit breakers in ... ground detection system indicates normal C. change over generators D. check each circuit with a megohmmeter

Last Answer : Answer: B

Description : During maintenance of circuit breakers, _______________. A. always smooth roughened contact surfaces with a file B. never pass more than rated breaker current through the overload heater element C. ... wear and misalignment of main contacts D. assume heater elements installed are of correct size

Last Answer : Answer: C

Description : Undervoltage trips are frequently installed on switchboard circuit breakers to trip ____________. A. out generators in the event of severe arcing or sparking B. out generators when there is reversal of power ... , but continues to run D. out generators when there is low voltage in the main circuit

Last Answer : Answer: D

Description : Periodic testing of circuit breakers is necessary to assure that a correctly rated and properly installed unit _________________. A. can trip faster as it increases in age B. will continue to provide ... not exceed its interrupting capacity D. be able to withstand at least 125% of applied voltage

Last Answer : Answer: B

Description : You can determine if a circuit breaker has tripped by ________________. A. examining the position of the handle B. checking for which of the breakers is warm C. looking for a burned-out link D. all of the above

Last Answer : Answer: A

Description : The purpose of a main switchboard circuit breaker's reverse-power trip is to _____________. A. prevent main circuit overload B. protect the circuit breaker blowout coil C. prevent alternator motorization D. prevent low voltage tripout

Last Answer : Answer: C

Description : A 'dead front' switchboard is one _____________. A. without switches on it B. with insulated switches and no exposed terminals C. without circuit breakers D. without safety hand rails nor rubber mats

Last Answer : Answer: B

Description : Protection against sustained overloads occurring in molded-case circuit breakers is provided by a/an __________. A. overvoltage release B. thermal acting trip C. thermal overload relay D. current overload relay

Last Answer : Answer: B

Description : The purpose of a short circuit forcing module (short time trip) installed in a branch line is to provide ____________. A. high speed clearance of low impedance short circuits in the branch B. ... C. isolation of short circuits by selective tripping of branch circuit breakers D. all of the above

Last Answer : Answer: D

Description : What are different types of circuit breakers employed in thermal power plant?

Last Answer : Answer: For low voltage operation 415/220V vacuum circuit breakers or air break circuit breakers are employed. For voltage ratings about 6.6kV and beyond SF6 circuit breakers are employed.

Description : What are different types of circuit breakers employed in thermal power plant?

Last Answer : For low voltage operation 415/220V vacuum circuit breakers or air break circuit breakers are employed. For voltage ratings about 6.6kV and beyond SF6 circuit breakers are employed.

Description : Why Isolation switches are provided along with the circuit breakers?

Last Answer : Isolation switches are provided for separating the disconnected element from the live portion of the system for the purpose of safety

Description : Air Blast Circuit Breakers Advantages Disadvantages

Last Answer : Air Blast Circuit Breakers Advantages Disadvantages In air blast circuit breakers, compressed air at a pressure of 20-30 kg/cm2 is employed as an arc quenching medium. Air blast circuit breakers ... air blast circuit breaker current chopping problem exists There is a problem of re-striking voltage

Description : Why we need isolation transformers in power circuit ? why cant we use breakers to isolate?

Last Answer : In Isolation transformer is used, if there is change in parameter values of any side, the other side parameters will remain unchanged.

Description : How direct tests are conducted in circuit breakers?

Last Answer : Using a short circuit generator as the source. Using the power utility system or network as the source.

Description : State the different types of circuit breakers.

Last Answer : Air ,oil,vacuum circuit breakers.

Description : Write the classifications of test conducted on circuit breakers.

Last Answer : Type test Routine test Reliability test Commissioning test

Description : Write the classification of circuit breakers based on the medium used for arc extinction?

Last Answer : Air break circuit breaker Oil circuit breaker Minimum oil circuit breaker Air blast circuit breaker SF6 circuit breaker Vacuum circuit breaker

Description : What are the protections provided in PMCC circuit breakers?

Last Answer : 1. IDMT O/C (CDG 34). 2. IDMT E/F (CDG 11).  3. Under voltage (40% of 110V). 

Description : What FCN was implemented to avoid reactor trip on 220V-DC failure of PHT and PPP breakers?

Last Answer : The breaker close position supervision relay VAA 21 is changed by VAJC type, contacts position do not change if 220V-DC is lost now.

Description : Why under voltage tripping of motor is incorporated in motor feeder breakers? 

Last Answer : The under voltage can occur in case of bus fault. If the motors are kept connected they will feed the fault which may cause the damage. Due to the back feeding from the motor the motor will slow down ... case pht motor will not rotate for the designed 3 minute period in case of bus under voltage).  

Description : Can you balance this SF4 plus F2 2 SF6?

Last Answer : Feel Free to Answer

Description : What is the shape of molecules SF6 and IF7 ?

Last Answer : SF6 is Octahedral IF7 is pentagonal Bipyramidal

Description : Why is SF4 more reactive than SF6 ?

Last Answer : Ans . SF4 has two unpaired electrons which it can donate further to extend its valency , hence it is reactive .’S’ in SF6 has maximum 6 0.S.

Description : Which of the following medium is employed for extinction of arc in air circuit breaker ? (a) Water (b) Oil (c) Air (d) SF6

Last Answer : (c) Air

Description : Which of the following GHGs has the longest atmospheric life time? a) CO2 b) CFC c) Sulfur Hexafluoride (SF6) d) perfluorocarbon (PFC)

Last Answer : d) perfluorocarbon (PFC)

Description : For which molecule can the bonding be described in terms of sp3 hybrid orbitals of the central atom? w) CH4 x) SF6 y) BF3 z) PCL5

Last Answer : ANSWER: B -- CH4

Description : Describe the construction of SF6 circuit breaker with neat diagram.

Last Answer : Construction of SF6 Circuit Breaker : A sulphur hexafluoride (SF6) circuit breaker consists of fixed and moving contacts enclosed in a chamber. The chamber is called arc interruption ... contact, moving contact and arcing horn are coated with a copper-tungsten arc-resistant material. 

Description : Name any two applications of following gases: (i) Nitrogen (ii) Hydrogen (iii) Sf6 (iv) Air. 

Last Answer : i) Applications of Nitrogen:  1. As a cooling agent. 2. To avoid oxidation. 3. Electrical insulating material (Gas) in electrical equipment. ii) Applications of Hydrogen:  1. High ... As a cooling agent in electrical machines. 2. Electrical insulating material (Gas) in electrical equipment.