Description : In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve
Last Answer : Ans: d
Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser
Last Answer : Ans: c
Description : Presence of moisture in a refrigerant affects the working of (a) compressor (b) condenser (c) evaparator (d) expansion valve.
Last Answer : Ans: a
Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected
Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used
Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer
Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect
Description : Condensing temperature in a refrigerator is the temperature (a) of cooling medium (b) of freezing zone (c) of evaporator (d) at which refrigerant gas becomes liquid
Description : The bank of tubes at the back of domestic refrigerator are (a) condenser tubes (b) evaporator tubes (c) refrigerant cooling tubes (d) capillary tubes
Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid
Description : One of the purposes of sub-cooling the liquid refrigerant is to (a) reduce compressor overheating (b) reduce compressor discharge temperature (c) increase cooling effect (d) ensure that only liquid and not the vapour enters the expansion (throttling) valve
Description : In a vapour compression cycle, the refrigerant immediately after expansion valve is (a) liquid (b) sub-cooled liquid (c) saturated liquid (d) wet vapour
Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor
Last Answer : Ans: D
Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve
Last Answer : Ans: b
Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve
Description : Where does the lowest temperature occur in a vapour compression cycle ? (a) condenser (b) evaporator (c) compressor (d) expansion valve
Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge
Description : Moisture in freon refrigeration system causes (a) ineffective refrigeration (b) high power consumption (c) freezing automatic regulating valve (d) corrosion of whole system
Description : What is sensible cooling of air? A. the cooling in which sensible heat of air is removed in order to reduce temperature B. the cooling in which temperature of air is reduced without changing in its moisture content C. both a. and b. D. none of the above
Last Answer : ANSWER : C
Description : An air washer can work as: A. Humidifier B. Dehumidifier C. Filter D. All of the above
Last Answer : ANSWER : D
Description : In milk chilling plant, the usual secondary refrigerant is (a)ammonia (b)sodium silicate (c) glycol (d) brine
Description : The coefficient of performance is the ratio of the refrigerant effect to the (a) heat of compression (b) work done by compressor (c) enthalpy increase in compressor (d) all of the above
Description : Choose the correct statement (a) A refrigerant should have low latent heat (b) If operating temperature of system is low, then refrigerant with low boiling point should be used (c) Pre-cooling and sub-cooling bf refrigerant are same (d) Superheat and sensible heat of a. refrigerant are same
Description : For proper refrigeration in a cabinet, if the temperature and vapour pressure difference between cabinet and atmosphereis high, then (a) bigger cabinet should be used (b) smaller cabinet should ... tight vapour seal should be used (d) refrigerant with lower evaporation temperature should be used
Description : In vapour compression cycle using NH3 as refrigerant, initial charge is filled at (a) suction of compressor (b) delivery of compressor (c) high pressure side close to receiver (d) low pressure side near receiver
Description : The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents (a) condensation of the refrigerant vapour (b) evaporation of the refrigerant liquid (c) compression of the refrigerant vapour (d) metering of the refrigerant liquid
Description : Aqua ammonia is used as refrigerant in the following type of refrigeration system (a) compression (b) direct (c) indirect (d) absorption
Description : A certain refrigerating system has a normal operating suction pressure of 10 kg/cm gauge and condensing pressure ofabout 67 kg/cm. The refrigerant used is (a) Ammonia (b) Carbon dioxide (c) Freon (d) Brine
Description : Highest pressure encountered in a refrigeration system should be (a) critical pressure of refrigerant (b) much below critical pressure (c) much above critical pressure (d) near critical pressure
Description : Which of the following is not a desirable property of a refrigerant (a) highmisibility with oil (b) low boiling point (c) good electrical conductor (d) large latent heat
Description : At lower temperatures and pressures, the latent heat of vaporization of a refrigerant (a) decreases (b) increases (c) remains same (d) depends on other factors
Description : Accumulators should have adequate volume to store refrigerant charge at least (a) 10% (b) 25% (c) 50% (d) 75%
Description : In refrigerators, the temperature difference between the evaporating refrigerant and the medium being cooled should be (a) high, of the order of 25° (b) as low as possible (3 to 11°C) (c) zero (d) any value
Description : Absorption system normally uses the following refrigerant (a) Freon-11 (b) Freon-22 (c) C02 (d) ammonia.
Last Answer : Ans: e
Description : In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is (a) less than 2 kg (b) more than or equal to 3.65 kg (c) more than 10 kg (d) there is no such consideration
Description : Highest temperature encountered in refrigeration cycle should be (a) near critical temperature of refrigerant (b) above critical temperature (c) atcritica. temperature (d) much below critical temperature
Description : The vapour pressure of refrigerant should be (a) lower than atmospheric pressure (b) higher than atmospheric pressure (c) equal to atmospheric pressure (d) could be anything
Description : Refrigeration in aeroplanes usually employs the following refrigerant (a) Co2 (b) Freon-11 (c) Freon-22 (d) Air
Description : The refrigerant for a refrigerator should have (a) high sensible heat (b) high total heat (c) high latent heat (d) low latent heat
Description : Which of the following cycles uses air as the refrigerant? (a) Ericsson (b) Stirling (c) Carnot (d) Bell-coleman
Description : The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P. (a) more (b) less (c) equally. (d) unpredictable
Description : The refrigeration effect in a dry evaporator compared to flooded evaporator in a similar plant is (a) same (b) more (c) less (d) more or less depending on ambient conditions
Description : Cooling water is required for following equipment in ammonia absorption plant (a) condenser (b) evaporator (c) condenser and absorber (d) condenser, absorber and separator (rectifier).
Description : The advantage of dry compression is that (a) it permits higher speeds to be used (b) it permits complete evaporation in the evaporator (c) it results in high volumetirc and mechanical efficiency (d) all of the above
Description : If the evaporator temperature of a plant is lowered, keeping the condenser temperature constant, the h.p. of compressorrequired will be (a) same (b) more (c) less (d) more/less depending on rating
Description : If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of - 23°C,then the Carnot COP will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Description : A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. TheCarnot coefficient of performance of cycle will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Description : Formation of frost on evaporator in refrigerator (a) results in loss of heat due to poor heat transfer (b) increases heat transfer rate (c) decreases compressor power. (d) can be avoided by proper design