Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge
Last Answer : Ans: a
Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser
Last Answer : Ans: c
Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor
Last Answer : Ans: D
Description : In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve
Last Answer : Ans: d
Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve
Last Answer : Ans: b
Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve
Description : In a vapour compression cycle, the refrigerant immediately after expansion valve is (a) liquid (b) sub-cooled liquid (c) saturated liquid (d) wet vapour
Description : Domestic refrigerator working on vapour compression cycle uses the following type of expansion device (a) electrically operated throttling valve (b) manually operated valve (c) thermostatic valve (d) capillary tube
Description : One of the purposes of sub-cooling the liquid refrigerant is to (a) reduce compressor overheating (b) reduce compressor discharge temperature (c) increase cooling effect (d) ensure that only liquid and not the vapour enters the expansion (throttling) valve
Description : Presence of moisture in a refrigerant affects the working of (a) compressor (b) condenser (c) evaparator (d) expansion valve.
Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid
Description : In vapour compression cycle using NH3 as refrigerant, initial charge is filled at (a) suction of compressor (b) delivery of compressor (c) high pressure side close to receiver (d) low pressure side near receiver
Description : The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P. (a) more (b) less (c) equally. (d) unpredictable
Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected
Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used
Description : If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of - 23°C,then the Carnot COP will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Description : A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. TheCarnot coefficient of performance of cycle will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect
Description : Which of the following units is not present in both the vapor compression refrigeration system and absorption refrigeration system? (A) Expansion valve (B) Condenser (C) Refrigerator (D) Compressor
Last Answer : (D) Compressor
Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant
Last Answer : (A) Increased COP
Description : The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is (A) Less pronounced (B) More pronounced (C) Equal (D) Data insufficient, can't be predicted
Last Answer : (B) More pronounced
Description : In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be (A) 5.2 (B) 6.2 (C) 0.168 (D) Data insufficient, can't be found out
Last Answer : A) 5.2
Description : Reducing suction pressure in refrigeration cycle (a) lowers evaporation temperature (b) increases power required per ton of refrigeration (c) lowers compressor capacity because vapour is lighter (d) all of the above.
Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer
Description : If the evaporator temperature of a plant is lowered, keeping the condenser temperature constant, the h.p. of compressorrequired will be (a) same (b) more (c) less (d) more/less depending on rating
Description : For better COP of refrigerator, the pressure range corresponding to temperature in evaporator and condenser must be (a) small (b) high (c) equal (d) anything
Description : The ratio of work done per cycle to the stroke volume of the compressor is known as A. Compressor capacity B. Compression ratio C. Compressor efficiency D. Mean effective pressure
Last Answer : ANSWER : D
Description : Cooling water is required for following equipment in ammonia absorption plant (a) condenser (b) evaporator (c) condenser and absorber (d) condenser, absorber and separator (rectifier).
Description : The bank of tubes at the back of domestic refrigerator are (a) condenser tubes (b) evaporator tubes (c) refrigerant cooling tubes (d) capillary tubes
Description : Most of the domestic refrigerators work on the following refrigeration system (a) vapour compression (b) vapour absorption (c) carnot cycle (d) electrolux refrigerator
Description : The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents (a) condensation of the refrigerant vapour (b) evaporation of the refrigerant liquid (c) compression of the refrigerant vapour (d) metering of the refrigerant liquid
Description : The value of COP in vapour compression cycle is usually (a) always less than unity (b) always more than unity (c) equal to unity (d) any one of the above
Description : The vapour compression refrigerator employs the following cycle (a) Rankine (b) Carnot (c) Reversed Carnot. (d) Brayton
Description : Ammonia-absorption refrigeration cycle requires (a) very little work input (b) maximum work input (c) nearly same work input as for vapour compression cycle (d) zero work input
Description : Vapour compression refrigeration is some what like (a) Carnot cycle (b) Rankine cycle (c) reversedCamot cycle (d) reversed Rankine cycle
Last Answer : Ans: C
Description : Formation of frost on evaporator in refrigerator (a) results in loss of heat due to poor heat transfer (b) increases heat transfer rate (c) decreases compressor power. (d) can be avoided by proper design
Description : Adiabatic compression is one in which A. Temperature during compression remains constant B. No heat leaves or enters the compressor cylinder during compression C. Temperature rise follows a linear relationship D. Work done is maximum.
Last Answer : ANSWER : B
Description : The moisture in a refrigerant is removed by (a) evaporator (b) safety relief valve (c) dehumidifier (d) driers
Description : The capacity of the compressor will be highest when its intake temperature is A. Lowest B. highest C. Atmospheric D. Unpredictable
Last Answer : ANSWER : C
Description : The advantage of dry compression is that (a) it permits higher speeds to be used (b) it permits complete evaporation in the evaporator (c) it results in high volumetirc and mechanical efficiency (d) all of the above
Description : In four stroke engine which of the following is also known as power stroke a. Suction stroke b. Compression stroke c. Expansion stroke d. Exhaust stroke (Ans:c) Measurements of fuel and air ... into IC engine,___________its efficiency A. increase B. decrease C. does not alter D. unpredictable on
Description : Reciprocating compressor are provided with A. Simple disc/plate valve B. Poppet valve C. Spring-loaded disc valve D. Solenoid valve.
Last Answer : ANSWER : A
Description : The coefficient of performance is the ratio of the refrigerant effect to the (a) heat of compression (b) work done by compressor (c) enthalpy increase in compressor (d) all of the above
Description : In a single acting reciprocating compressor, the suction, compression and delivery of air takes place in A. One stroke B. Two stroke C. Three stroke D. Four stroke
Description : The clearance volume of the air compressor is kept minimum because A. It allows maximum compression to be achieved B. It greatly affects volumetric efficiency C. It results in minimum work D. It permits isothermal compression
Description : In multi stage compressor, the isothermal compression is achieved by A. Employing intercooler B. By constantly cooling the cylinder C. By running compressor at very slow speed D. By insulating the cylinder
Description : Volumetric efficiency of a compressor without clearance volume A. Increases with increase in compression ratio B. Decreases wit increase in compression ratio C. Not dependent upon compression ratio D. Unpredictable
Description : Work input to the air compressor with n as index of compression A. Increases with increase in value of n B. Decrease with increase in value of n C. remains same whatever the value of n D. first increase and then decreases with increase of value of n.