Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected
Last Answer : Ans: a
Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used
Description : A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. TheCarnot coefficient of performance of cycle will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Last Answer : Ans: c
Description : In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve
Last Answer : Ans: d
Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser
Description : If the evaporator temperature of a plant is lowered, keeping the condenser temperature constant, the h.p. of compressorrequired will be (a) same (b) more (c) less (d) more/less depending on rating
Last Answer : Ans: b
Description : The refrigeration effect in a dry evaporator compared to flooded evaporator in a similar plant is (a) same (b) more (c) less (d) more or less depending on ambient conditions
Description : The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is (A) Less pronounced (B) More pronounced (C) Equal (D) Data insufficient, can't be predicted
Last Answer : (B) More pronounced
Description : Where does the lowest temperature occur in a vapour compression cycle ? (a) condenser (b) evaporator (c) compressor (d) expansion valve
Description : If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of - 23°C,then the Carnot COP will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge
Description : In a refrigeration cycle, the super heating……..C.O.P (a)decreases (b)does not change (c) increases (d)none of the above
Description : The specific fuel consumption of a petrol engine compared to diesel engine of same H.P is A. same B.more C. less D. unpredictable
Last Answer : ANSWER : B
Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer
Description : For better COP of refrigerator, the pressure range corresponding to temperature in evaporator and condenser must be (a) small (b) high (c) equal (d) anything
Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect
Description : The air requirement of a petrol engine during starting compared to the theoretical air requirement for complete combustion is A. more B.unpredictable C. same D. less
Last Answer : ANSWER : D
Description : The area of actual indicator diagram on an air compressor as compared to area of ideal indicator diagram is A. Less B. More C. Same D. Unpredictable
Description : Cooling water is required for following equipment in ammonia absorption plant (a) condenser (b) evaporator (c) condenser and absorber (d) condenser, absorber and separator (rectifier).
Description : The bank of tubes at the back of domestic refrigerator are (a) condenser tubes (b) evaporator tubes (c) refrigerant cooling tubes (d) capillary tubes
Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant
Last Answer : (A) Increased COP
Description : In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be (A) 5.2 (B) 6.2 (C) 0.168 (D) Data insufficient, can't be found out
Last Answer : A) 5.2
Description : A diesel engine compared to petrol engine, running at full load is A. less efficient B. equally efficient C. more efficient D. other factors will decide it
Last Answer : ANSWER : C
Description : Reducing suction pressure in refrigeration cycle (a) lowers evaporation temperature (b) increases power required per ton of refrigeration (c) lowers compressor capacity because vapour is lighter (d) all of the above.
Description : Highest temperature encountered in refrigeration cycle should be (a) near critical temperature of refrigerant (b) above critical temperature (c) atcritica. temperature (d) much below critical temperature
Description : The fuel air ratio in a petrol engine fitted with suction carburetor, operating with dirty air filter as compared to clean filter will be A. higher B. lower C. remain unaffected D. unpredictable
Last Answer : ANSWER : A
Description : Air refrigeration cycle is used in (a) domestic refrigerators (b) gas liquefaction (c)commercial refrigerators (d) Chillers
Description : Most of the domestic refrigerators work on the following refrigeration system (a) vapour compression (b) vapour absorption (c) carnot cycle (d) electrolux refrigerator
Description : Under-cooling in a refrigeration cycle (a) increases COP (b) decreases COF (c) COP remains unaltered (d) other factors decide COP
Description : Superheating in a refrigeration cycle (a) increases COP (b) decreases COP (c) COP remains unaltered (d) other factors decide COP
Description : The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents (a) condensation of the refrigerant vapour (b) evaporation of the refrigerant liquid (c) compression of the refrigerant vapour (d) metering of the refrigerant liquid
Description : Air refrigeration cycle is used in (a) domestic refrigerators (b) commercial refrigerators (c) air conditioning (d) gas liquefaction
Description : Air refrigeration operates on (a) Carnot cycle (b) Reversed Carnot cycle (c) Rankine cycle (d) Brayton cycle.
Description : Ammonia-absorption refrigeration cycle requires (a) very little work input (b) maximum work input (c) nearly same work input as for vapour compression cycle (d) zero work input
Description : Vapour compression refrigeration is some what like (a) Carnot cycle (b) Rankine cycle (c) reversedCamot cycle (d) reversed Rankine cycle
Last Answer : Ans: C
Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor
Last Answer : Ans: D
Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve
Description : Compressor at high altitude will draw A. More power B. Less power C. Same power D. Unpredictable
Description : For the same peak pressure and heat input a. Otto cycle is more efficient b. Diesel cycle is more efficient c. Both are equally efficient d. None of the above
Last Answer : ANSWER b. Diesel cycle is more efficient
Description : For same compression ratio and heat input a. Otto cycle is more efficient b. Diesel cycle is more efficient c. Both are equally efficient d. None of the above
Last Answer : ANSWER a. Otto cycle is more efficient
Description : The general rule for rating refrigeration systems (excepting for CO2 system) is to approximate following h.p. per ton of Refrigeration (a) 0.1 to 0.5 h.p. per ton of refrigeration (b) 0.5 to 0.8 h.p. per ... (c) 1 to 2 h.p. per ton of refrigeration (d) 2 to 5 h.p. per ton of refrigeration
Description : When the dew point temperature is equal to the air temperature then the relative humidity is A. 0% B. 50% C. 100% D. unpredictable
Description : In four stroke engine which of the following is also known as power stroke a. Suction stroke b. Compression stroke c. Expansion stroke d. Exhaust stroke (Ans:c) Measurements of fuel and air ... into IC engine,___________its efficiency A. increase B. decrease C. does not alter D. unpredictable on
Description : The capacity of the compressor will be highest when its intake temperature is A. Lowest B. highest C. Atmospheric D. Unpredictable
Description : If the intake air temperature of Internal combustion engine increases, its efficiency will a. increase b. decrease c.remains same d unpredictable
Last Answer : ANSWER b. decrease
Description : In a refrigeration system, heat absorbed in comparison to heat rejected is (a) more (b) less (c) less for small capacity and more for high capacity. (d) more for small capacity and less for high capacity
Description : In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is (a) less than 2 kg (b) more than or equal to 3.65 kg (c) more than 10 kg (d) there is no such consideration