In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve

1 Answer

Answer :

Ans: d

Related questions

Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser

Last Answer : Ans: c

Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor

Last Answer : Ans: D

Description : Where does the lowest temperature occur in a vapour compression cycle ? (a) condenser (b) evaporator (c) compressor (d) expansion valve

Last Answer : Ans: b

Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge

Last Answer : Ans: a

Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected

Last Answer : Ans: a

Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used

Last Answer : Ans: a

Description : Presence of moisture in a refrigerant affects the working of (a) compressor (b) condenser (c) evaparator (d) expansion valve.

Last Answer : Ans: a

Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve

Last Answer : Ans: b

Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve

Last Answer : Ans: d

Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve

Last Answer : Ans: c

Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve

Last Answer : Ans: a

Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect

Last Answer : Ans: a

Description : The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P. (a) more (b) less (c) equally. (d) unpredictable

Last Answer : Ans: a

Description : A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. TheCarnot coefficient of performance of cycle will be (a) 0.2 (b) 1.2 (c) 5 (d) 6

Last Answer : Ans: c

Description : One of the purposes of sub-cooling the liquid refrigerant is to (a) reduce compressor overheating (b) reduce compressor discharge temperature (c) increase cooling effect (d) ensure that only liquid and not the vapour enters the expansion (throttling) valve

Last Answer : Ans: d

Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer

Last Answer : Ans: a

Description : The bank of tubes at the back of domestic refrigerator are (a) condenser tubes (b) evaporator tubes (c) refrigerant cooling tubes (d) capillary tubes

Last Answer : Ans: a

Description : In a vapour compression cycle, the refrigerant immediately after expansion valve is (a) liquid (b) sub-cooled liquid (c) saturated liquid (d) wet vapour

Last Answer : Ans: d

Description : Which of the following units is not present in both the vapor compression refrigeration system and absorption refrigeration system? (A) Expansion valve (B) Condenser (C) Refrigerator (D) Compressor

Last Answer : (D) Compressor

Description : The moisture in a refrigerant is removed by (a) evaporator (b) safety relief valve (c) dehumidifier (d) driers

Last Answer : Ans: d

Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant

Last Answer : (A) Increased COP

Description : The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents (a) condensation of the refrigerant vapour (b) evaporation of the refrigerant liquid (c) compression of the refrigerant vapour (d) metering of the refrigerant liquid

Last Answer : Ans: b

Description : Highest temperature encountered in refrigeration cycle should be (a) near critical temperature of refrigerant (b) above critical temperature (c) atcritica. temperature (d) much below critical temperature

Last Answer : Ans: d

Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid

Last Answer : Ans: d

Description : If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of - 23°C,then the Carnot COP will be (a) 0.2 (b) 1.2 (c) 5 (d) 6

Last Answer : Ans: d

Description : In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is (a) less than 2 kg (b) more than or equal to 3.65 kg (c) more than 10 kg (d) there is no such consideration

Last Answer : Ans: b

Description : In vapour compression cycle using NH3 as refrigerant, initial charge is filled at (a) suction of compressor (b) delivery of compressor (c) high pressure side close to receiver (d) low pressure side near receiver

Last Answer : Ans: c

Description : Reducing suction pressure in refrigeration cycle (a) lowers evaporation temperature (b) increases power required per ton of refrigeration (c) lowers compressor capacity because vapour is lighter (d) all of the above.

Last Answer : Ans: d

Description : Condensing temperature in a refrigerator is the temperature (a) of cooling medium (b) of freezing zone (c) of evaporator (d) at which refrigerant gas becomes liquid

Last Answer : Ans: d

Description : For proper refrigeration in a cabinet, if the temperature and vapour pressure difference between cabinet and atmosphereis high, then (a) bigger cabinet should be used (b) smaller cabinet should ... tight vapour seal should be used (d) refrigerant with lower evaporation temperature should be used

Last Answer : Ans: c

Description : Aqua ammonia is used as refrigerant in the following type of refrigeration system (a) compression (b) direct (c) indirect (d) absorption

Last Answer : Ans: d

Description : Highest pressure encountered in a refrigeration system should be (a) critical pressure of refrigerant (b) much below critical pressure (c) much above critical pressure (d) near critical pressure

Last Answer : Ans: b

Description : Refrigeration in aeroplanes usually employs the following refrigerant (a) Co2 (b) Freon-11 (c) Freon-22 (d) Air

Last Answer : Ans: d

Description : The refrigeration effect in a dry evaporator compared to flooded evaporator in a similar plant is (a) same (b) more (c) less (d) more or less depending on ambient conditions

Last Answer : Ans: c

Description : Cooling water is required for following equipment in ammonia absorption plant (a) condenser (b) evaporator (c) condenser and absorber (d) condenser, absorber and separator (rectifier).

Last Answer : Ans: d

Description : If the evaporator temperature of a plant is lowered, keeping the condenser temperature constant, the h.p. of compressorrequired will be (a) same (b) more (c) less (d) more/less depending on rating

Last Answer : Ans: b

Description : For better COP of refrigerator, the pressure range corresponding to temperature in evaporator and condenser must be (a) small (b) high (c) equal (d) anything

Last Answer : Ans: a

Description : Domestic refrigerator working on vapour compression cycle uses the following type of expansion device (a) electrically operated throttling valve (b) manually operated valve (c) thermostatic valve (d) capillary tube

Last Answer : Ans: d

Description : The coefficient of performance is the ratio of the refrigerant effect to the (a) heat of compression (b) work done by compressor (c) enthalpy increase in compressor (d) all of the above

Last Answer : Ans: d

Description : Formation of frost on evaporator in refrigerator (a) results in loss of heat due to poor heat transfer (b) increases heat transfer rate (c) decreases compressor power. (d) can be avoided by proper design

Last Answer : Ans: a

Description : Moisture in freon refrigeration system causes (a) ineffective refrigeration (b) high power consumption (c) freezing automatic regulating valve (d) corrosion of whole system

Last Answer : Ans: c

Description : The bank of tubes located at the back of the domestic refrigerators are the __________ tubes. (A) Refrigerant cooling (B) Evaporator (C) Condenser (D) Throttling

Last Answer : C) Condenser

Description : The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is (A) Less pronounced (B) More pronounced (C) Equal (D) Data insufficient, can't be predicted

Last Answer : (B) More pronounced

Description : In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be (A) 5.2 (B) 6.2 (C) 0.168 (D) Data insufficient, can't be found out

Last Answer : A) 5.2

Description : Reciprocating compressor are provided with A. Simple disc/plate valve B. Poppet valve C. Spring-loaded disc valve D. Solenoid valve.

Last Answer : ANSWER : A

Description : Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor)? (A) Freon (B) Liquid sulphur dioxide (C) Methyl chloride (D) Ammonia

Last Answer : (A) Freon

Description : In a refrigeration cycle, the super heating……..C.O.P (a)decreases (b)does not change (c) increases (d)none of the above

Last Answer : Ans: a

Description : Air refrigeration cycle is used in (a) domestic refrigerators (b) gas liquefaction (c)commercial refrigerators (d) Chillers

Last Answer : Ans: b

Description : Most of the domestic refrigerators work on the following refrigeration system (a) vapour compression (b) vapour absorption (c) carnot cycle (d) electrolux refrigerator

Last Answer : Ans: a

Description : Under-cooling in a refrigeration cycle (a) increases COP (b) decreases COF (c) COP remains unaltered (d) other factors decide COP

Last Answer : Ans: a