Description : In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve
Last Answer : Ans: d
Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge
Last Answer : Ans: a
Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor
Last Answer : Ans: D
Description : Where does the lowest temperature occur in a vapour compression cycle ? (a) condenser (b) evaporator (c) compressor (d) expansion valve
Last Answer : Ans: b
Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve
Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect
Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Last Answer : Ans: c
Description : One of the purposes of sub-cooling the liquid refrigerant is to (a) reduce compressor overheating (b) reduce compressor discharge temperature (c) increase cooling effect (d) ensure that only liquid and not the vapour enters the expansion (throttling) valve
Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid
Description : In a vapour compression cycle, the refrigerant immediately after expansion valve is (a) liquid (b) sub-cooled liquid (c) saturated liquid (d) wet vapour
Description : Presence of moisture in a refrigerant affects the working of (a) compressor (b) condenser (c) evaparator (d) expansion valve.
Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant
Last Answer : (A) Increased COP
Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected
Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used
Description : The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents (a) condensation of the refrigerant vapour (b) evaporation of the refrigerant liquid (c) compression of the refrigerant vapour (d) metering of the refrigerant liquid
Description : Which of the following units is not present in both the vapor compression refrigeration system and absorption refrigeration system? (A) Expansion valve (B) Condenser (C) Refrigerator (D) Compressor
Last Answer : (D) Compressor
Description : Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor)? (A) Freon (B) Liquid sulphur dioxide (C) Methyl chloride (D) Ammonia
Last Answer : (A) Freon
Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer
Description : In vapour compression cycle using NH3 as refrigerant, initial charge is filled at (a) suction of compressor (b) delivery of compressor (c) high pressure side close to receiver (d) low pressure side near receiver
Description : The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is (A) Less pronounced (B) More pronounced (C) Equal (D) Data insufficient, can't be predicted
Last Answer : (B) More pronounced
Description : In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be (A) 5.2 (B) 6.2 (C) 0.168 (D) Data insufficient, can't be found out
Last Answer : A) 5.2
Description : The bank of tubes at the back of domestic refrigerator are (a) condenser tubes (b) evaporator tubes (c) refrigerant cooling tubes (d) capillary tubes
Description : The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P. (a) more (b) less (c) equally. (d) unpredictable
Description : A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. TheCarnot coefficient of performance of cycle will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Description : Domestic refrigerator working on vapour compression cycle uses the following type of expansion device (a) electrically operated throttling valve (b) manually operated valve (c) thermostatic valve (d) capillary tube
Description : Aqua ammonia is used as refrigerant in the following type of refrigeration system (a) compression (b) direct (c) indirect (d) absorption
Description : For proper refrigeration in a cabinet, if the temperature and vapour pressure difference between cabinet and atmosphereis high, then (a) bigger cabinet should be used (b) smaller cabinet should ... tight vapour seal should be used (d) refrigerant with lower evaporation temperature should be used
Description : The moisture in a refrigerant is removed by (a) evaporator (b) safety relief valve (c) dehumidifier (d) driers
Description : Reducing suction pressure in refrigeration cycle (a) lowers evaporation temperature (b) increases power required per ton of refrigeration (c) lowers compressor capacity because vapour is lighter (d) all of the above.
Description : The coefficient of performance is the ratio of the refrigerant effect to the (a) heat of compression (b) work done by compressor (c) enthalpy increase in compressor (d) all of the above
Description : Most of the domestic refrigerators work on the following refrigeration system (a) vapour compression (b) vapour absorption (c) carnot cycle (d) electrolux refrigerator
Description : In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is (a) less than 2 kg (b) more than or equal to 3.65 kg (c) more than 10 kg (d) there is no such consideration
Description : Condensing temperature in a refrigerator is the temperature (a) of cooling medium (b) of freezing zone (c) of evaporator (d) at which refrigerant gas becomes liquid
Description : Ammonia-absorption refrigeration cycle requires (a) very little work input (b) maximum work input (c) nearly same work input as for vapour compression cycle (d) zero work input
Description : Vapour compression refrigeration is some what like (a) Carnot cycle (b) Rankine cycle (c) reversedCamot cycle (d) reversed Rankine cycle
Last Answer : Ans: C
Description : The benchmarking parameter for a vapour compression refrigeration system is a) kW / kg of refrigerant used b) kcal / m3 of chilled water c) BTU / Ton of Refrigeration d) kW / Ton of Refrigeration
Last Answer : d) kW / Ton of Refrigeration
Description : Highest pressure encountered in a refrigeration system should be (a) critical pressure of refrigerant (b) much below critical pressure (c) much above critical pressure (d) near critical pressure
Description : Highest temperature encountered in refrigeration cycle should be (a) near critical temperature of refrigerant (b) above critical temperature (c) atcritica. temperature (d) much below critical temperature
Description : Refrigeration in aeroplanes usually employs the following refrigerant (a) Co2 (b) Freon-11 (c) Freon-22 (d) Air
Description : The refrigeration effect in a dry evaporator compared to flooded evaporator in a similar plant is (a) same (b) more (c) less (d) more or less depending on ambient conditions
Description : Cooling water is required for following equipment in ammonia absorption plant (a) condenser (b) evaporator (c) condenser and absorber (d) condenser, absorber and separator (rectifier).
Description : If the evaporator temperature of a plant is lowered, keeping the condenser temperature constant, the h.p. of compressorrequired will be (a) same (b) more (c) less (d) more/less depending on rating
Description : If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of - 23°C,then the Carnot COP will be (a) 0.2 (b) 1.2 (c) 5 (d) 6
Description : For better COP of refrigerator, the pressure range corresponding to temperature in evaporator and condenser must be (a) small (b) high (c) equal (d) anything
Description : Formation of frost on evaporator in refrigerator (a) results in loss of heat due to poor heat transfer (b) increases heat transfer rate (c) decreases compressor power. (d) can be avoided by proper design
Description : An ideal liquid refrigerant should (A) Not have a sub-atmospheric vapour pressure at the temperature in the refrigerator coils (B) Not have unduly high vapour pressure at the condenser temperature (C) Both (A) and (B) (D) Have low specific heat
Last Answer : (C) Both (A) and (B)
Description : Moisture in freon refrigeration system causes (a) ineffective refrigeration (b) high power consumption (c) freezing automatic regulating valve (d) corrosion of whole system
Description : The vapour pressure of refrigerant should be (a) lower than atmospheric pressure (b) higher than atmospheric pressure (c) equal to atmospheric pressure (d) could be anything