Description : The condition of refrigerant before entering the expansion or throttle valve, in a vapour compression system (a) dry vapour (b) wet vapour (c)liquid-vapour mixture (d) high pressure saturated liquid
Last Answer : Ans: d
Description : In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Description : In vapour compression cycle, the condition of refrigerant is saturated liquid (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion throttle valve (d) before entering the expansion valve
Last Answer : Ans: a
Description : In vapour compression cycle the condition off refrigerant is dry saturated vapour (a) after passing through the condenser (b) before passing through the condenser (c)before entering the expansion valve (d) before entering the compressor
Last Answer : Ans: D
Description : In vapour compression cycle, the condition of refrigerant is very wet vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) before entering the expansion valve
Last Answer : Ans: c
Description : In vapour compression cycle the condition of refrigerant is superheated vapour (a) after passing through the condenser (b) before passing through the condenser (c) after passing through the expansion or throttle valve (d) beforeentering the expansion valve
Last Answer : Ans: b
Description : In vapour compression refrigeration system, refrigerant occurs as liquid between (a) condenser and expansion valve (b) compressor and evaporator (c) expansion valve and evaporator (d) compressor and condenser
Description : One of the purposes of sub-cooling the liquid refrigerant is to (a) reduce compressor overheating (b) reduce compressor discharge temperature (c) increase cooling effect (d) ensure that only liquid and not the vapour enters the expansion (throttling) valve
Description : The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents (a) condensation of the refrigerant vapour (b) evaporation of the refrigerant liquid (c) compression of the refrigerant vapour (d) metering of the refrigerant liquid
Description : Where does the lowest temperature occur in a vapour compression cycle ? (a) condenser (b) evaporator (c) compressor (d) expansion valve
Description : The higher temperature in vapour compression cycle occurs at (a) compressor discharge. (b) expansion valve (c) evaporator (d) condenser discharge
Description : Domestic refrigerator working on vapour compression cycle uses the following type of expansion device (a) electrically operated throttling valve (b) manually operated valve (c) thermostatic valve (d) capillary tube
Description : In vapour compression cycle using NH3 as refrigerant, initial charge is filled at (a) suction of compressor (b) delivery of compressor (c) high pressure side close to receiver (d) low pressure side near receiver
Description : In a refrigeration cycle, the flow of refrigerant is controlled by (a) compressor (b) condenser (c) evaporator (d) expansion valve
Description : Which of the following situations can be approximated to a steady state heat transfer system? (A) A red hot steel slab (having outside surface temperature as 1300°C) exposed to the atmospheric air at ... flowing at the rate of 6 Kg/minute through a copper pipe exposed to atmospheric air at 35°C
Last Answer : (B) 10 kg of dry saturated steam at 8 kgf/cm2 flowing through a short length of stainless steel pipe exposed to atmospheric air at 35°C
Description : Presence of moisture in a refrigerant affects the working of (a) compressor (b) condenser (c) evaparator (d) expansion valve.
Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer
Description : A liquid under pressure greater than its vapour pressure for the temperature involved is called a __________ liquid. (A) Sub-cooled (B) Saturated (C) Non-solidifiable (D) None of these
Last Answer : (A) Sub-cooled
Description : In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to (a) collect liquid refrigerant and prevent it from going to compressor (b) detect liquid in vapour (c) superheat the vapour (d) increase refrigeration effect
Description : In refrigerators, the temperature difference between the evaporating refrigerant and the medium being cooled should be (a) high, of the order of 25° (b) as low as possible (3 to 11°C) (c) zero (d) any value
Description : Most of the domestic refrigerators work on the following refrigeration system (a) vapour compression (b) vapour absorption (c) carnot cycle (d) electrolux refrigerator
Description : The value of COP in vapour compression cycle is usually (a) always less than unity (b) always more than unity (c) equal to unity (d) any one of the above
Description : The vapour compression refrigerator employs the following cycle (a) Rankine (b) Carnot (c) Reversed Carnot. (d) Brayton
Description : Ammonia-absorption refrigeration cycle requires (a) very little work input (b) maximum work input (c) nearly same work input as for vapour compression cycle (d) zero work input
Description : Vapour compression refrigeration is some what like (a) Carnot cycle (b) Rankine cycle (c) reversedCamot cycle (d) reversed Rankine cycle
Last Answer : Ans: C
Description : The temperature to which a vapour gas mixture must be cooled (at varying humidity) to become saturated is called the __________ temperature. (A) Dew point (B) Wet bulb (C) Dry bulb (D) None of these
Last Answer : (D) None of these
Description : For proper refrigeration in a cabinet, if the temperature and vapour pressure difference between cabinet and atmosphereis high, then (a) bigger cabinet should be used (b) smaller cabinet should ... tight vapour seal should be used (d) refrigerant with lower evaporation temperature should be used
Description : The vapour pressure of refrigerant should be (a) lower than atmospheric pressure (b) higher than atmospheric pressure (c) equal to atmospheric pressure (d) could be anything
Description : The moisture in a refrigerant is removed by (a) evaporator (b) safety relief valve (c) dehumidifier (d) driers
Description : The coefficient of performance is the ratio of the refrigerant effect to the (a) heat of compression (b) work done by compressor (c) enthalpy increase in compressor (d) all of the above
Description : Aqua ammonia is used as refrigerant in the following type of refrigeration system (a) compression (b) direct (c) indirect (d) absorption
Description : Choose the correct statement (a) A refrigerant should have low latent heat (b) If operating temperature of system is low, then refrigerant with low boiling point should be used (c) Pre-cooling and sub-cooling bf refrigerant are same (d) Superheat and sensible heat of a. refrigerant are same
Description : Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor)? (A) Freon (B) Liquid sulphur dioxide (C) Methyl chloride (D) Ammonia
Last Answer : (A) Freon
Description : An ideal liquid refrigerant should (A) Not have a sub-atmospheric vapour pressure at the temperature in the refrigerator coils (B) Not have unduly high vapour pressure at the condenser temperature (C) Both (A) and (B) (D) Have low specific heat
Last Answer : (C) Both (A) and (B)
Description : The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperatureconstant, will (a) increase (b) decrease (c) may increase or decrease depending on the type of refrigerant used (d) remain unaffected
Description : The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will (a) increase (b) decrease (c) remain unaffected (d) may increase or decrease depending on the type of refrigerant used
Description : Highest temperature encountered in refrigeration cycle should be (a) near critical temperature of refrigerant (b) above critical temperature (c) atcritica. temperature (d) much below critical temperature
Description : __________ is the temperature at which a gas-vapor mixture becomes saturated, when cooled at constant total pressure out of contact with a liquid. (A) Dew point (B) Bubble point (C) Dry bulb temperature (D) Wet bulb temperature
Last Answer : (A) Dew point
Description : The dew point temperature is less than the wet bulb temperature for A. saturated air B. unsaturated air C. both saturated and unsaturated air D. none of the above
Last Answer : ANSWER : B
Description : The temperature of air recorded by thermometer when the bulb is covered by a cotton wick saturated by water is called as A. dry bulb temperature B. wet bulb temperature C. stream temperature D. psychrometric temperature
Description : __________________ is a liquid at the saturations which has temperature equal to the boiling point corresponding to the existing pressure. a. Saturation Temperature b. Sub cooled Liquid c. Compressed Liquid d. Saturated Liquid
Last Answer : Saturated Liquid
Description : _________________ is one which has a pressure higher than the saturation pressure corresponding to the existing temperature. a. Saturation Temperature b. Sub cooled Liquid c. Compressed Liquid d. Saturated Liquid
Last Answer : Compressed Liquid
Description : ________________ is one which has a temperature lower than the saturation temperature corresponding to the existing pressure. a. Saturation Temperature b. Sub cooled Liquid c. Compressed Liquid d. Saturated Liquid
Last Answer : Sub cooled Liquid
Description : ______________ is the temperature at which liquids start to boil or the temperature at which vapors begin to condense. a. Saturation Temperature b. Sub cooled Liquid c. Compressed Liquid d. Saturated Liquid
Last Answer : Saturation Temperature
Description : Condensing temperature in a refrigerator is the temperature (a) of cooling medium (b) of freezing zone (c) of evaporator (d) at which refrigerant gas becomes liquid
Description : In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is (a) less than 2 kg (b) more than or equal to 3.65 kg (c) more than 10 kg (d) there is no such consideration
Description : The COP of a vapour compression plant in comparison to vapour absorption plant is (a) more (b) less (c) same (d) more/less depending on size of plant
Description : Relative humidity is a) the ratio of water vapour in the air compared to the total amount water vapour the air could contain at a given temperature b) equal to the dry bulb temperature divided by the wet bulb ... of dry air e) the ratio of the mass of water vapour divided by the mass of wet air
Last Answer : ANSWER : A
Description : When dry bulb temperature (DBT) and wet bulb temperature (WBT) are measured, greater the difference between DBT and WBT, A. greater the amount of water vapour held in the mixture B. smaller the amount of ... the mixture C. same the amount of water vapour held in the mixture D. none of the above
Description : In sub-cooled boiling, (A) Temperature of the heating surface is less than the boiling point of the liquid (B) Temperature of the heating surface is more than the boiling point of the liquid (C) ... from heating surface are absorbed by the mass of the liquid (D) Very large vapour space is necessary
Last Answer : (B) Temperature of the heating surface is more than the boiling point of the liquid