Inverse definite minimum time lag relay is also called ___________
(A) pilot relay. (B) differential relay.
(C) over current relay. (D) directional overcurrent relay.

1 Answer

Answer :

Ans: B
Inverse definite minimum time lag relay characteristic is inverse but minimum time is
fixed. The operating time is inversely proportional to the magnitude of actuating
quantity.

Related questions

Description : Purpose of Directional inverse Over current & earth fault relay; type- CDD

Last Answer : Directional phase or earth fault protection of ring-mains, parallel transformers, transformer feeders, parallel feeders etc., employing the time graded principle.; This relay comprises an inductive ... induction disc unit. The directional unit is normally provided with voltage polarising coils. 

Description : The purpose of a magnetic relay is to _____________. A. open a circuit only in the event of overload B. remotely open and close contacts C. provide overcurrent protection during starting D. relay voltages at increased power

Last Answer : Answer: B

Description : What is the characteristic of inverse time over current relay?  

Last Answer : If the fault current increases the time of the operation of the relay will be decreases.  

Description : Purpose of over current relay (Inverse); type- CDG  

Last Answer : It is a self powered inverse time over current and earth fault relay, used for selective phase and earth fault protection in time graded systems for A.C. machines, transformers, feeders ... it rotates the driving torque increases and offsets the changing restraining torque of the control spring. 

Description : The purpose of the automatic bus transfer shown in the illustration is to ___________. EL-0014 A. stepdown voltage to the lighting distribution panel B. provide emergency power to ... emergency switchboard from the main switchboard D. provide overcurrent protection to the lighting distribution panel

Last Answer : Answer: B

Description : The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above

Last Answer : (b) internal short-circuits

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Description : In a static over-current relay, inverse time characteristics are obtained by   (a) A differentiating circuit (b) An integrating circuit (c) A transistor amplifier (d) A transistor switch

Last Answer : B

Description : Explain construction and operation of induction type directional over current relay.

Last Answer : Directional overcurrent relay: Construction: It consists of two units: i) Non-directional Over-current unit ii) Directional power unit The directional unit consists of upper electromagnet ... closes the trip circuit. This operates circuit breaker which isolates the faulty section. 

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Last Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Description : In induction type directional over current relay the driving torque is due to interaction of magnetic fields derived from (A) current in the potential coil (B) both voltage and current in the ... (C) directional element and non-directional element (D) non-directional element and the trip circuit

Last Answer : In induction type directional over current relay the driving torque is due to interaction of magnetic fields derived from directional element and non-directional element

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : What are the features of directional relay?

Last Answer : High speed operation; high sensitivity; ability to operate at low voltages; adequate short-time thermal ratio; burden must not be excessive.

Description : An instantaneous-trip-type fuse will _____________. A. open as soon as the load current exceeds its set point B. allow a preset delay between overcurrent and melting C. open a circuit by using a time delay element with a magnetic trip D. reset itself when the overcurrent is corrected

Last Answer : Answer: A

Description : A circuit breaker for a 300 KW alternator is rated at 470 amperes of full continuous load. The amount of overcurrent allowed is 125%. Which of the following conditions will trip the breaker? A. ... 10 minutes. C. Momentary starting load of 550 amperes. D. Sustained current flow of 590 amperes.

Last Answer : Answer: D

Description : A series resistance is added to the over-current relay in a bus bar differential protection scheme which: a. Helps to develop some voltage across it which otherwise should appear across the relay and is ... the effects of CT saturation and lowers the pickup value of the relay d. All of the above 

Last Answer : A series resistance is added to the over-current relay in a bus bar differential protection scheme which: a. Helps to develop some voltage across it which otherwise should appear across the relay and is ... the effects of CT saturation and lowers the pickup value of the relay d. All of the above 

Description : Mention any two applications of differential relay.

Last Answer : Protection of generator & generator transformer unit; protection of large motors and busbars .

Description : Will main generator differential relay pick up for generator earth faults? 

Last Answer : No earth fault current limited to 5A, while differential setting is 10%. 

Description : The greatest single cause of electrical failures is ______. A. the breakdown of insulation B. overcurrent C. high inductance D. too frequent testing

Last Answer : Answer: A

Description : The speed of a series wound winch motor is controlled by ____________. A. varying the voltage applied to the motor B. the weight of the load on the cargo boom C. overcurrent protection devices in the motor D. a hydraulic speed-limiting governor

Last Answer : Answer: A

Description : Burning of controller contacts, when opening, is prevented by _____________. A. coating the contact surfaces lightly with petroleum jelly B. magnetic blowout coils C. an overvoltage release D. an overcurrent release

Last Answer : Answer: B

Description : When voltage increases then current also increases then what is the need of over voltage relay and over current relay? Can we measure over voltage and over current by measuring current only?

Last Answer : No. We can't sense the over voltage by just measuring the current only because the current increases not only for over voltages but also for under voltage (As most of the loads are non-linear in ... So, for a better protection of the system. It should have both over voltage & over current relay.

Description : When voltage increases then current also increases then why we need of over voltage relay and over current relay? Can we measure over voltage and over current by measuring current only?

Last Answer : No. We cannot sense the over voltage by just measuring the current only because the current increases not only for over voltages but also for under voltage (As most of the loads are non-linear in ... , for a better protection of the system. It should have both over voltage & over current relay.

Description : The change in enthalpy per unit weight of adsorbed gas when adsorbed on gas free or "outgassed" adsorbent to from a definite concentration of adsorbate is called its (A) Integral heat of adsorption (B) Heat of wetting (C) Differential heat of adsorption (D) Heat of normal condensation

Last Answer : (A) Integral heat of adsorption

Description : Describe the operation of current differential relay with neat sketch.

Last Answer : Operation of Current Differential Relay: Figure shows an arrangement of an overcurrent relay connected to operate as a differential relay for alternator protection under fault conditon. ... current flows through relay coil, causing relay to operate for protection of alternator winding.

Description : The change in enthalpy, when a unit quantity of gas is absorbed by relatively large quantity of adsorbent (on which a definite concentration of the adsorbed gas already exists) is termed as the (A) ... (B) Heat of wetting (C) Integral heat of adsorption (D) None of these

Last Answer : (A) Differential heat of adsorption

Description : Mention some of the applications of Directional Over-Current relays?

Last Answer : 1. Double end fed power system 2. Single end fed system of parallel feeders 3. Ring main feeder system

Description : ECE Board Exam March 1996 The letter-number designation B8E is a form of modulation also known as ___________. A. pilot carrier system B. independent sideband emission C. lincomplex D. vestigial sideband transmission

Last Answer : B. independent sideband emission

Description : The relay with inverse time characteristic will operate within (a) 1.5 sec (b) 5 to 10 sec (c) 5 to 20 sec (d) 20 to 30 sec (e) none of the above

Last Answer : (b) 5 to 10 sec

Last Answer : The relay with inverse time characteristic will operate within 5 to 10 sec.

Description : Admittance relay is _______ relay. (a) impedance (b) directional (c) non-directional (d) none of the above

Last Answer : (b) directional

Description : The transmission line distance protection relay having the property of being inherently directional is (A) impedance relay (B) MHO relay (C) OHM relay (D) reactance relay

Last Answer : The transmission line distance protection relay having the property of being inherently directional is MHO relay

Description : 30°, 60° and 90° connections are made in a directional relay to render the relay (A) Sufficient torque under fault conditions (B) Zero torque under fault conditions (C) Current grading (D) Time grading

Last Answer : 30°, 60° and 90° connections are made in a directional relay to render the relay Sufficient torque under fault conditions

Description : If the phase -angle of the voltage coil of a directional relay is 50°, the maximum torque angle of the relay is: (A) 130° (B) 100° (C) 50° (D) 25°

Last Answer : If the phase -angle of the voltage coil of a directional relay is 50°, the maximum torque angle of the relay is: 50°

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : A circuit is protected from overheating by a/an ___________. A. pyrometer B. thermal overload relay C. magnetic contactor D. overload transformer

Last Answer : Answer: B

Description : To overcome the lag in the operating speeds of the I/O device and the processor we use ___________ a) BUffer spaces b) Status flags c) Interrupt signals d) Exceptions

Last Answer : Status flags

Description : What is the direction of current through the load resistor in the circuit shown in the illustration? EL-0085 A. Always from point 'Z' to the grounded end. B. Always from the grounded end to ... on the instantaneous polarity at point 'W'. D. It cannot be determined without a directional ammeter.

Last Answer : Answer: B

Description : Possible phase relationships between voltage and current in an alternating current circuit include which of the following conditions? A. Current and voltage may be in phase. B. Current may lead the voltage. C. Current may lag the voltage. D. All of the above.

Last Answer : Answer: D

Description : At dead short circuit at terminals of Alternator then the current I is a) ZPF Lag b) ZPF lead c) Unity power factor d) 0.8 Power factor lag

Last Answer : Ans: ZPF Lag

Description : A differential relay measures the vector difference between (a) two currents (b) two voltages (c) two or more similar electrical quantities (d) none of the above

Last Answer : (c) two or more similar electrical quantities

Description : In a biased differential relay, the bias is defined as the ratio of  A) Number of turns of restraining coil and operating coil B) Operating coil current and restraining coil current C) Faulteurrent and operating coil current D) Fault current and restraining coil current

Last Answer : In a biased differential relay, the bias is defined as the ratio of Number of turns of restraining coil and operating coil 

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Last Answer : d

Last Answer : A differential relay measures the vector difference between two or more similar electrical quantities.

Description : In accordance with Coast Guard Regulations (46 CFR), each battery operated relay-controlled lantern must _____________. A. be readily portable B. contain a dry cell battery having a minimum capacity of ... automatic battery charger to maintain the battery in a fully charged state D. all of the above

Last Answer : Answer: C

Description : What is a differential amplifier? Also, explain CMRR.

Last Answer : Differential Amplifier: The amplifier, which is used to amplify the voltage difference between two input-lines neither of which is grounded, is called differential amplifier. This reduces the amount of noise ... , CMRR would be infinite because in that case common mode voltage gain would be zero.

Description : What is the difference between over voltage relay and over current relay?

Last Answer : A:The current increases not only for over voltages but also for under voltage(As most of the loads are non-linear in nature). So,the over voltage protection & over current protection are completely ... , for a better protection of the system.It should have both over voltage & over current relay.