What type of flow measurement devices is best for slurries?

1 Answer

Answer :

Any device that restricts the flow to perform measurements is not recommended for slurries. These  devices include orifices and dampeners. These devices can lead to liquid/solid separation and they can  lead to excessive erosion. Instead, measuring devices that do not restrict the flow should be used. One  example of such a device is the magnetic flow meter.

Related questions

Description : Which of the following is the most suitable for handling fibrous and dense slurries? (A) Propeller agitator (B) Cone type agitator (C) Turbine agitator

Last Answer : (B) Cone type agitator

Description : Multistage centrifugal pumps are generally used for (A) High head (B) Low head but high discharge (C) Highly viscous liquid (D) Slurries of high solid concentration

Last Answer : (A) High head

Description : Reciprocating pumps compared to centrifugal pumps (A) Deliver liquid at uniform pressure (B) Can handle slurries more efficiently (C) Are not subject to air binding (D) Can be operated with delivery valve closed

Last Answer : (C) Are not subject to air binding

Description : Diaphragm pumps are used to transport (A) Solids (B) Liquids (C) Fluids (D) Slurries

Last Answer : (D) Slurries

Description : Plunger pumps are used for (A) Higher pressure (B) Slurries (C) Viscous mass (D) None of these

Last Answer : (A) Higher pressure

Description : Slurries can be most conveniently pumped by a __________ pump. (A) Screw (B) Reciprocating (C) Gear (D) Centrifuga

Last Answer : (D) Centrifuga

Description : What is some common piping materials used to transport slurries?

Last Answer : When selecting a piping material to transport slurries, corrosion and erosion considerations must be accounted for. Some of the most popular piping materials include: ► Carbon Steel ► Stainless ... polyvinyl chloride (uPVC) ► Fiberglass reinforced plastic (FRP) ► Elastomer-lined carbon steel

Description : Are there any general rules that should be considered when designing a slurry piping system? The following are items to consider when designing a piping system that will transport slurries:

Last Answer : 1) Whenever possible, piping should be designed to be self-draining 2) Manual draining should be installed to drain sections of the piping when self-draining is not possible 3) Blow-out or ... flanges should be provided every 20 feet of horizontal pipe or after every two changes in direction

Description : In hot wire anemometer used for gas flow measurement, the wire is normally made of (A) Copper (B) Platinum (C) Constantan (D) Chromium

Last Answer : (B) Platinum

Description : Flow measurement in an open channel is done by a/an (A) Venturimeter (B) Orificemeter (C) Weir (D) Rotameter

Last Answer : (C) Weir

Description : A Venturimeter cannot be used for the direct measurement of (A) Datum difference in the stretch of pipe-flow (B) Pressure difference in the flow through pipeline (C) Friction loss in pipe flow (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Which of the following is used for very accurate measurement of flow of gas at low velocity? (A) Pitot tube (B) Rotameter (C) Segmental orificemeter (D) Hot wire anemometer

Last Answer : (D) Hot wire anemometer

Description : A pycnometer is used for the measurement of (A) Flow rate of molten metal (B) Specific gravity of a liquid (C) Composition of alloys (D) Concentration of a solution

Last Answer : Option B

Description : Draw and explain Doppler type flow measurement.

Last Answer : Doppler type ultrasonic flow meter ➢ Explianation: The Doppler Effect Ultrasonic Flow meter use reflected ultrasonic waves to measure the fluid velocity. There is a change in ultrasonic ... , there will be a frequency shift at the receiver end which is protentional to the velocity

Description : Out of the following flow measuring devices, which one incurs themaximum installation cost as well as pressure loss? (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) Orificemeter

Last Answer : (B) Venturimeter

Description : Which of the following flow measuring devices is an area meter? (A) Venturimeter (B) Orificemeter (C) Anemometer (D) Rotameter

Last Answer : (D) Rotameter

Description : what are the top 10 Fluid Flow Measurement Application Questions?

Last Answer : Is the measured process media a liquid or a gas?Is the flow measurement occurring in a pipe or in an open channel?What is the the flow rate?How much does the flow vary?If ... flowmeter technologies can be accommodated in the location?What types of post installation service is available in area?

Description : what is the 10 Fluid Flow Measurement Application Questions?

Last Answer : Is the measured process media a liquid or a gas?Is the flow measurement occurring in a pipe or in an open channel?What is the the flow rate?How much does the flow vary?If ... flowmeter technologies can be accommodated in the location?What types of post installation service is available in area?

Description : Why does the v notch give more accurate flow measurement than any other weirs?

Last Answer : Need answer

Description : Measurement of insulin clearance test is a measure of (A) Glomerular filtration rate (B) Filtration factor (C) Renal plasma flow (D) Tubular secretory mass

Last Answer : Answer : A

Description : Urea clearance test is used to determine the (A) Glomerular filtration rate (B) Renal plasma flow (C) Ability of kidney to concentrate the urine (D) Measurement of tubular mass

Last Answer : Answer : A

Description : Which of the following project baselines provides the basis for measurement of  the expected cash flow against requirements over time and is often displayed as an  S curve? Select one: a. Schedule baseline b. Cost performance baseline c. Scope baseline d. Plan baseline e. Initiation baseline

Last Answer : b. Cost performance baseline

Description : State some elements of flow measurement. 

Last Answer : Orifice, Venturi tubes, flowrator (rotameter) etc.  

Description : Pitot tube is used for measurement of (A) Pressure (B) Flow (C) Velocity (D) Discharge

Last Answer : Answer: Option C

Description : What Are The Primary Elements Usedfor Flow Measurement?

Last Answer : The primary elements used for flow measurement are: 1. Orifice Plate. 2. Venturi tube. 3. Pitot tube. 4. Annubars. 5. Flow Nozzle. 6. Weir & Flumes.

Description : The instrument for measurement of flow/ velocity is________. A. Bimetallic. C) Turbine meter. B. Manometer. D) Wattmeter

Last Answer : Turbine meter

Description : Measurement of inulin renal clearance is a measure for (A) Effective renal blood flow (B) Renal drug excretion rate (C) Active renal secretion (D) Glomerular filtration rate

Last Answer : (D) Glomerular filtration rate

Description : What are the primary elements used for flow measurement?

Last Answer : The primary elements used for flow measurement are: • Orifice Plate. • Venturi tube. • Pitot tube. • Annubars. • Flow Nozzle. • Weir & Flumes.

Description : The calibration of an HPLC detector can be evaluated by measurement of? A. Retention time B. Temperature C. Flow rate accuracy D. Intensity of the peak

Last Answer : D. Intensity of the peak

Description : Write the names of any four flow meters used for flow measurement.

Last Answer : Flow meters used for flow measurement : Rotating vane meter, ultrasonic flow meter, Piston type flow meter, thermal flow meter, electromagnetic flow meter.

Description : Explain with neat labelled diagram measurement of flow using venturi meter

Last Answer : Explanation: It is a primary element of differential pressure Flow meters. 1) It consists of a straight inlet section, a converging conical inlet section, a cylindrical throat and diverging recovery ... abruptly, so permanent pressure loss or energy loss is very low as compared to orifice plate.

Description : Describe with neat labeled diagram measurement of flow using turbine flow meter.

Last Answer : Explanation: - Turbine flow meter s are volumetric flow meters and are available in wide ranges. The output is usually in the form of a digital electrical signal whose frequency is directly ... totalized by a counter to give the value of total flow over a particular interval of time.

Description : Data flow between two devices canoccur in a _______ way. A) simplex B) half-duplex C) full-duplex D) all of theabove

Last Answer : all of theabove

Description : The functions of a Logical Link Layer (LLC) are a. Error control b. Flow control c. Creating and managing the communication link between two devices with the help of the Transport layer. d. All the above

Last Answer : d. All the above

Description : The functions of a Logical Link Layer (LLC) are ___. A. Error control B. Flow control C. Creating and managing the communication link between two devices with the help of the Transport layer. D. All the above

Last Answer : D. All the above

Description : For dynamic strain measurement, the Wheatstone bridge used is of __________ type. (A) Voltage sensitive null (B) Voltage sensitive deflected (C) Current sensitive deflected (D) None of these

Last Answer : (B) Voltage sensitive deflected