State some elements of flow measurement. 

1 Answer

Answer :

Orifice, Venturi tubes, flowrator (rotameter) etc.  

Related questions

Description : State some elements of pressure measurement. 

Last Answer : Manometer, Diaphragm gauges, Bellows, Strain gauges etc.  

Description : What Are The Primary Elements Usedfor Flow Measurement?

Last Answer : The primary elements used for flow measurement are: 1. Orifice Plate. 2. Venturi tube. 3. Pitot tube. 4. Annubars. 5. Flow Nozzle. 6. Weir & Flumes.

Description : What are the primary elements used for flow measurement?

Last Answer : The primary elements used for flow measurement are: • Orifice Plate. • Venturi tube. • Pitot tube. • Annubars. • Flow Nozzle. • Weir & Flumes.

Description : Pick up the correct statement from the following: (A) Topology describes the geometric characteristic of objects which do not change under transformations and are independent of any coordinate system ... The three elements of topology are adjacency, containment, and connectivity (D) All of these

Last Answer : Answer: Option D

Description : Electrostatic type instruments are mainly used for measurement of: a) Heavy currents b) Low currents c) Low voltages d) High voltages

Last Answer : Ans: D

Description : When a resistor is used as a shunt and is connected in parallel with a meter movement coil, it will provide _____________. A. a measurement of circuit resistance B. an increased accuracy of approximately 1.5 percent C. an extended meter range D. none of the above

Last Answer : Answer: C

Description : In order to increase its range of measurement, a resistance would be placed in series with which of the following instruments? A. DC voltmeter B. DC ammeter C. frequency meter D. power factor meter

Last Answer : Answer: A

Description : What is meant by tan-delta measurement?

Last Answer : It is the tan of the angle between the capacitive current and the total current.   As the value of tan delta increases the resistive component of the current in increasing. Hence it shows a weak insulation.  

Description : What is the equation for resistance measurement of PT 100 thermocouple? 

Last Answer : °C = (R-100) / 0.39  

Description : What is the purpose of rotor AC Impedance measurement?

Last Answer : Periodic measurement of rotor impedance using an AC power supply is another means of detecting the presence of shorted turns in a rotor winding. Impedance measurement is more sensitive than the ... single shorted turn opposes the MMF of the entire coil, thus greatly reducing the reactance. 

Description : What is the purpose of tan-delta measurement? 

Last Answer : Insulation in electrical system has parameters such as Capacitance, Die-electric loss, and Power factor. By detecting the changes in these parameters failures can be revealed. In this tan-delta ... insulation. This detects moisture and void in the insulation. This indicates amount of ionization. 

Description : What is the necessity of shaft voltage measurement?

Last Answer : It is to observe insulation of bearing 6 & 7 and hydrogen seal assembly. It requires minimum leakage current (<100mA) through bearings and shaft seals to avoid pitting of bearings. ... >100mA, clean the insulation provided between bearing pedestal and seal housing with earth. 

Description : What should be the frequency of measurement of earth resistivity?

Last Answer : As per IS: 3043, 1987, measurement of earth resistivity should be carried out annually or biannually and value should be recorded. 

Description : What is the instrument name used for accurate measurement of IP? 

Last Answer : Infra red spectro photometer.  

Description : Draw a neat sketch and explain the use of CT and PT for measurement of power in a single-phase circuit?

Last Answer : If wattmeter of proper range is not available or if voltage and current ranges are high we can usr CT and PT of suitable ratio. Connect the CT and PT as shown in figure. The reading of wattmeter can be multiplied by the ratio to get the actual power.   

Description : What are the limits of vibration measurement for motors?

Last Answer : 50 microns for displacement and 5 mm/second for velocity.

Description : In dielectric measurement, the dielectric loss is proportional to a) F b) V c) I d) Vsqr

Last Answer : Ans: Vsqr

Description : The two watt meters measurement the ratio of two meter readings is –(1-sqrt3):( 1+sqrt3) then the power factor is a) 1 b) 0.866 c) 0.707 d) 0

Last Answer : Ans: 0.707

Description : what are the top 10 Fluid Flow Measurement Application Questions?

Last Answer : Is the measured process media a liquid or a gas?Is the flow measurement occurring in a pipe or in an open channel?What is the the flow rate?How much does the flow vary?If ... flowmeter technologies can be accommodated in the location?What types of post installation service is available in area?

Description : what is the 10 Fluid Flow Measurement Application Questions?

Last Answer : Is the measured process media a liquid or a gas?Is the flow measurement occurring in a pipe or in an open channel?What is the the flow rate?How much does the flow vary?If ... flowmeter technologies can be accommodated in the location?What types of post installation service is available in area?

Description : Why does the v notch give more accurate flow measurement than any other weirs?

Last Answer : Need answer

Description : Measurement of insulin clearance test is a measure of (A) Glomerular filtration rate (B) Filtration factor (C) Renal plasma flow (D) Tubular secretory mass

Last Answer : Answer : A

Description : Urea clearance test is used to determine the (A) Glomerular filtration rate (B) Renal plasma flow (C) Ability of kidney to concentrate the urine (D) Measurement of tubular mass

Last Answer : Answer : A

Description : In hot wire anemometer used for gas flow measurement, the wire is normally made of (A) Copper (B) Platinum (C) Constantan (D) Chromium

Last Answer : (B) Platinum

Description : Which of the following project baselines provides the basis for measurement of  the expected cash flow against requirements over time and is often displayed as an  S curve? Select one: a. Schedule baseline b. Cost performance baseline c. Scope baseline d. Plan baseline e. Initiation baseline

Last Answer : b. Cost performance baseline

Description : Flow measurement in an open channel is done by a/an (A) Venturimeter (B) Orificemeter (C) Weir (D) Rotameter

Last Answer : (C) Weir

Description : A Venturimeter cannot be used for the direct measurement of (A) Datum difference in the stretch of pipe-flow (B) Pressure difference in the flow through pipeline (C) Friction loss in pipe flow (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Which of the following is used for very accurate measurement of flow of gas at low velocity? (A) Pitot tube (B) Rotameter (C) Segmental orificemeter (D) Hot wire anemometer

Last Answer : (D) Hot wire anemometer

Description : A pycnometer is used for the measurement of (A) Flow rate of molten metal (B) Specific gravity of a liquid (C) Composition of alloys (D) Concentration of a solution

Last Answer : Option B

Description : Pitot tube is used for measurement of (A) Pressure (B) Flow (C) Velocity (D) Discharge

Last Answer : Answer: Option C

Description : The instrument for measurement of flow/ velocity is________. A. Bimetallic. C) Turbine meter. B. Manometer. D) Wattmeter

Last Answer : Turbine meter

Description : Measurement of inulin renal clearance is a measure for (A) Effective renal blood flow (B) Renal drug excretion rate (C) Active renal secretion (D) Glomerular filtration rate

Last Answer : (D) Glomerular filtration rate

Description : What type of flow measurement devices is best for slurries?

Last Answer : Any device that restricts the flow to perform measurements is not recommended for slurries. These devices include orifices and dampeners. These devices can lead to liquid/solid separation and they can lead to ... the flow should be used. One example of such a device is the magnetic flow meter.

Description : The calibration of an HPLC detector can be evaluated by measurement of? A. Retention time B. Temperature C. Flow rate accuracy D. Intensity of the peak

Last Answer : D. Intensity of the peak

Description : Write the names of any four flow meters used for flow measurement.

Last Answer : Flow meters used for flow measurement : Rotating vane meter, ultrasonic flow meter, Piston type flow meter, thermal flow meter, electromagnetic flow meter.

Description : Explain with neat labelled diagram measurement of flow using venturi meter

Last Answer : Explanation: It is a primary element of differential pressure Flow meters. 1) It consists of a straight inlet section, a converging conical inlet section, a cylindrical throat and diverging recovery ... abruptly, so permanent pressure loss or energy loss is very low as compared to orifice plate.

Description : Draw and explain Doppler type flow measurement.

Last Answer : Doppler type ultrasonic flow meter ➢ Explianation: The Doppler Effect Ultrasonic Flow meter use reflected ultrasonic waves to measure the fluid velocity. There is a change in ultrasonic ... , there will be a frequency shift at the receiver end which is protentional to the velocity

Description : Describe with neat labeled diagram measurement of flow using turbine flow meter.

Last Answer : Explanation: - Turbine flow meter s are volumetric flow meters and are available in wide ranges. The output is usually in the form of a digital electrical signal whose frequency is directly ... totalized by a counter to give the value of total flow over a particular interval of time.