Flow measurement in an open channel is done by a/an
(A) Venturimeter
(B) Orificemeter
(C) Weir
(D) Rotameter

1 Answer

Answer :

(C) Weir

Related questions

Description : Which of the following can be used for the direct measurement of volumetric flow rate of slurry? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Water flow rate in a pipe of 3.5 metres diameter can be most economically and conveniently measured by a/an (A) Pitot tube (B) Venturimeter (C) Orificemeter (D) Rotameter

Last Answer : (A) Pitot tube

Description : The pressure head of a flow meter remains constant for (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Pitot tube

Last Answer : (C) Rotameter

Description : Out of the following flow measuring devices, which one incurs themaximum installation cost as well as pressure loss? (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) Orificemeter

Last Answer : (B) Venturimeter

Description : Which of the following flow measuring devices is an area meter? (A) Venturimeter (B) Orificemeter (C) Anemometer (D) Rotameter

Last Answer : (D) Rotameter

Description : Which is the most efficient and best for measuring very small flow rate of gases? (A) Venturimeter (B) Orificemeter (C) Rotameter (D) Flow nozzle

Last Answer : (C) Rotameter

Description : Which of the following is used for very accurate measurement of flow of gas at low velocity? (A) Pitot tube (B) Rotameter (C) Segmental orificemeter (D) Hot wire anemometer

Last Answer : (D) Hot wire anemometer

Description : Select the wrong statement pertaining to flow of an incompressible fluid through a Venturimeter. (A) For frictionless flow, the fluid pressure entering the venturi meter will be exactly equal ... than an orificemeter (D) Venturimeter incurs less power loss compared to an equivalent orificemeter

Last Answer : (C) Venturimeter occupies less space than an orificemeter

Description : For the same flow rate of a fluid, the pressure drop is the least for (A) Venturimeter (B) Orificemeter (C) Flow-nozzle (D) Δp is same for all

Last Answer : (A) Venturimeter

Description : For a given fluid flow rate, which of the following incurs maximum head loss? (A) Orificemeter (B) Venturimeter (C) Flow nozzle (D) All of them incur the same head loss

Last Answer : (A) Orificemeter

Description : . It is possible to integrate an automatic flow controller to a (A) Flow nozzle (B) Venturimeter (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : In a/an __________, the flow rate of fluids is obtained by measuring the difference between the impact and the static pressure. (A) Rotameter (B) Pitot tube (C) Venturimeter (D) Flow nozzle

Last Answer : (B) Pitot tube

Description : Flow of water in a pipe about 3 metres in diameter can be measured by (A) Orifice plate (B) Venturimeter (C) Rotameter (D) Pitot tube

Last Answer : Answer: Option D

Description : Open channel liquid flow is most conveniently measured by a (A) Hot wire anemometer (B) Notch (C) Rotameter (D) Segmental orifice

Last Answer : (B) Notch

Description : __________ is used for measuring the static pressure exerted on the wall by a fluid flowing parallel to the wall in a pipeline. (A) Venturimeter (B) Pressure gauge (C) Pitot tube (D) Orificemeter

Last Answer : (C) Pitot tube

Description : Venturimeter and orificemeter measures the __________ of the fluid. (A) Pressure (B) Maximum velocity (C) Average velocity (D) Point velocity

Last Answer : (C) Average velocity

Description : Bernoulli’s equation does not apply to the functioning of a/an (A) Venturimeter (B) Orificemeter (C) pitot tube (D) None of these

Last Answer : (D) None of these

Description : Power loss in an orificemeter is __________ that in a Venturimeter. (A) Less than (B) Same as (C) More than (D) Data insufficient, cannot be predicted

Last Answer : (C) More than

Description : Which is not a variable head meter? (A) Venturimeter (B) Pitot tube (C) Rotameter (D) None of these

Last Answer : (C) Rotameter

Description : Which of the following instrument can be used for measuring speed of an aeroplane? (A) Venturimeter (B) Orifice plate (C) Pitot tube (D) Rotameter

Last Answer : Answer: Option C

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : A Venturimeter cannot be used for the direct measurement of (A) Datum difference in the stretch of pipe-flow (B) Pressure difference in the flow through pipeline (C) Friction loss in pipe flow (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : A weir is used to measure the large water discharge rate from a river or from an open channel. A weir is not of __________ shape. (A) Circular (B) Rectangular (C) Triangular (D) Trapezoidal

Last Answer : (A) Circular

Description : The flow of water after spilling over the weir crest in chute spillway and side channel spillway respectively are (A) At right angle and parallel to weir crest (B) Parallel and at right angle to weir crest (C) Parallel to weir crest in both (D) At right angle to weir crest in both

Last Answer : Answer: Option A

Description : The absolute percentage error in the computed discharge over a rectangular weir corresponding to an absolute error of 1.5 % in the measurement of head over the sill of the weir would be : (a) 1.5 (b) 2.25 (c) 2.5 (d) 3.75

Last Answer : (b) 2.25

Description : A mercury (specific gravity = 13.6) manometer connected across an orificemeter fitted in a pipe shows a manometer reading of 2 cms. If the manometer liquid is changed to carbon tetrachloride (specific gravity = 1.6), then ... new manometer reading will be __________ cms. (A) 17 (B) 42 (C) 84 (D) 1.8

Last Answer : __________ cms. (A) 17

Description : Vena-contracta formed during flow of a liquid through an orificemeter has (A) Minimum liquid cross-section (B) More diameter compared to orifice diameter (C) Minimum velocity of fluid stream (D) None of these

Last Answer : (A) Minimum liquid cross-section

Description : The most serious disadvantage of an orificemeter is that (A) It is not very accurate (B) It is very costly (C) Most of the pressure drop is not recoverable (D) It is not suitable for measuring gas flow

Last Answer : (C) Most of the pressure drop is not recoverable

Description : A control meter is preferred to a weir because (A) It measures the discharge even in silt Leiden streams (B) The velocity of approach of the channel increases above the control, and thus removes the silt completely (C) It is not damaged by floating debris (D) All the above

Last Answer : Answer: Option D

Description : Which of the following may be termed as a variable orifice flow-meter? (A) Rotameter (B) Pitot tube (C) V-notch (D) All (A), (B) and (C)

Last Answer : (A) Rotameter

Description : A Rotameter through which air at room temperature and atmospheric pressure is flowing gives a certain reading for a flow rate of 100 cc/sec. If helium (molecular weight 4) is used and Rotameter shows the same reading, the flow rate (cc/sec) is (A) 26 (B) 42 (C) 269 (D) 325

Last Answer : (C) 269

Description : In area meter (e.g., Rotameter), with increase in the fluid flow rate, the (A) Pressure drop increases linearly (B) Pressure drop is almost constant (C) Area through which fluid flows does not vary (D) None of these

Last Answer : (B) Pressure drop is almost constant

Description : Flow rate of high velocity flue gas discharged through a stack to the atmosphere can be most conveniently measured by a (A) Pitot tube (B) Manometer (C) Rotameter (D) None of these

Last Answer : (A) Pitot tube

Description : Drag force on the float of a Rotameter is (where Q = flow rate of the) (A) ∝ Q (B) ∝ √Q (C) ∝ Q2 (D) Constant

Last Answer : (D) Constant

Description : the fluid flow rate increases, the float of the Rotameter (A) Rises in the tube (B) Rotates at higher speed (C) Rotates at lower speed (D) Drops down in the tube

Last Answer : Option A

Description : Sele(A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement. (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement

Description : Select the correct statement. (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter

Description : The energy loss in flow through Venturimeter is less than that through flow nozzle, because in case of a flow nozzle, the (A) Length is shorter (B) Throat diameter is more (C) Sudden expansion of flow in the downstream occurs (D) Distance between the throat and the inlet is more

Last Answer : (C) Sudden expansion of flow in the downstream occurs

Description : Pick out the correct statement pertaining to Venturimeter. (A) A Venturimeter with a fixed pressure drop discharges more, when the flow is vertically downward, than when the flow is vertically upward (B ... , when compressibility is taken into account, than when it is neglected (D) None of these

Last Answer : (D) None of these

Description : Venturimeter is used to measure the flow rate of fluids in pipes, when the pipe is in __________ position. (A) Horizontal (B) Vertical (C) Inclined (D) Any

Last Answer : (D) Any

Description : Rotameter is a device used to measure (A) Absolute pressure (B) Velocity of fluid (C) Flow (D) Rotation

Last Answer : Answer: Option C

Description : Related to ultrasonic flow meter: (i) Give any two types of it. (ii) Write any two specifications. (iii) Write two advantages over rotameter. 

Last Answer : (i) Two types of ultrasonic flow meter:  ➢ Transit time flow meters (time differences) ➢ Doppler type. (ii) Write any two specifications: - 1. Accuracy 2. Linearity 3. Repeatability 4. ... for bidirectional flow 8. Excellent dynamic response 9. Good accuracy +-2% 10. o/p is electrical

Description : The main function of a divide wall is to (A) Control the silt entry in the canal (B) Prevent river floods from entering the canal (C) Separate the under-sluices from weir proper (D) Provide smooth flow at sufficiently low velocity

Last Answer : Answer: Option C

Description : In order to measure the flow with a Venturimeter, it is installed in (A) Horizontal line (B) Inclined line with flow upwards (C) Inclined line with flow downwards (D) Any direction and in any location

Last Answer : Answer: Option D

Description : For measuring flow by a Venturimeter, if should be installed in (A) Vertical line (B) Horizontal line (C) Inclined line with flow downward (D) In any direction and in any location

Last Answer : Answer: Option D

Description : Which of the following statement is wrong? (A) A flow whose streamline is represented by a curve is called two dimensional flow. (B) The total energy of a liquid particle is the sum of potential energy, ... (D) A pitot tube is used to measure the velocity of flow at the required point in a pipe.

Last Answer : Answer: Option C

Description : Which of the following instruments is used to measure flow on the application of Bernoulli's theorem? (A) Venturimeter (B) Orifice plate (C) Nozzle (D) All of the above

Last Answer : Answer: Option D

Description : When the Venturimeter is inclined, then for a given flow it will show __________ reading. (A) Same (B) More (C) Less (D) None of these

Last Answer : Answer: Option A

Description : Venturimeter is used to measure: (1) rate of flow of liquids (2) liquid pressure (3) surface tension (4) liquid density

Last Answer : rate of flow of liquids

Description : Vena-contracta pressure tapping is at a distance __________ from the position of an orificemeter fitted in a pipe of internal diameter 'd' (A) d (B) 0.5 d (C) 2d (D) 4d

Last Answer : (B) 0.5 d