The frequency response of test equipment refers to what  aspect of ac voltage measurements?

1 Answer

Answer :

the range of frequencies that can accurately be measured.

Related questions

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : Why should you avoid using ac-powered test equipment when wearing a wrist strap?

Last Answer : For your own safety.

Description : How does the supply voltage affect the accuracy of Wheatstone bridge measurements?

Last Answer : As the supply voltage increases, bridge components may heat up and become less accurate.

Description : When making voltage measurements in a high-resistance circuit, you should always use a voltmeter with what relative value of resistance?

Last Answer : . High.

Description : Why is a dead-zone fiber placed between the test fiber and OTDR when conducting attenuation measurements?

Last Answer : To reduce the effect of the initial reflection at the OTDR

Description : Which of the following refers to a management tool for organizing personnel, facilities, equipment, and communication for any emergency situation? a) The Incident Command System The ... emergency preparedness required by the Joint Commission on Accreditation of Healthcare Organizations (JCAHO).

Last Answer : a) The Incident Command System The Incident Command System (ICS) is a management tool for organizing personnel, facilities, equipment and communication for any emergency situation. The federal government mandates ... are used at the level of an individual hospital's emergency response plan as well.

Description : Ships’ generators produce 450-volt, three-phase, ac power; however, most equipment uses 117-volt, single-phase power What transformers and connections are used to convert 450- volt, threephase power to 117-volt, single-phase power?

Last Answer : A method of generating oscillations, a method of turning the oscillations on and off (keying), and an antenna to radiate the energy.

Description : When using a multimeter for resistance measurements, it should be calibrated by clipping the loose ends of the leads together and _____________. A. setting the instrument pointer at 'zero' ohms B. ... the plus and minus terminals D. using a special purpose resistance measuring instrument (a bridge)

Last Answer : Answer: A

Description : What component in an amplifier circuit tends to limit the low-frequency response of the amplifier?

Last Answer : The coupling capacitor (C3).

Description : What compone What components What components can be used to increase the high frequency response of an amplifier?

Last Answer : Peaking coils.

Description : What is the major factor that limits the high-frequency response of an amplifier circuits?

Last Answer : The capacitance of the circuit.

Description : What are the factors that limit the frequency response of a transistor amplifier?

Last Answer : The capacitance and inductance of the circuit and the interelectrode capacitance of the transistor.

Description : List four factors that can degrade the frequency response of magnetic tape recorders.

Last Answer : a. A too-high or too-low bias signal level setting for the record head. b. An improper reproduce head gap. c. An improper tape transport speed. d. Poor tape-to-head contact.

Description : While measuring frequency response, as the signal generator approaches the lowest and highest frequency the recorder can effectively record, the VTVM reading drops to less than - 3 dB. What does this indicate?

Last Answer : The upper and lower limits of the frequency response specification for that tape recorder.

Description : The frequency-response specification of your tape recorder reads within +/ - 3 dB from 150 Hz to 150 kHz at 60 ips. What does this mean?

Last Answer : The recorder can record all frequencies between 150 Hz and 150 kHz at 60 ips without varying the output amplitude more than 3 dB.

Description : Which digital data encoding method helps overcome a tape recorder’s low-frequency response problems by recording two logic levels for each incoming data bit?

Last Answer : Bi-phase level encoding.

Description : Name the modulation system in which the frequency alternates between two discrete values in response to the opening and closing of a key?

Last Answer : . Frequency-shift keying.

Description : Two AC generators of the same capacity are operating in parallel. One with a zero speed droop setting and the other with a 5% speed droop. If its capacity is not exceeded, the unit whose ... B. maintain the frequency of the system C. have poor sensitivity characteristics D. have poor power response

Last Answer : Answer: B

Description : What equipment uses a calibrated resonant circuit to measure frequency?

Last Answer : Wavemeter.

Description : When checking a diode with an ohmmeter, what is indicated by two high resistance measurements?

Last Answer : The diode is open or has a high-forward resistance.

Description : Radar surface-angular measurements are referenced to true north and measured in what plane?

Last Answer : Horizontal plane.

Description : What are the three units of measure most commonly used when referring to af power measurements?

Last Answer : DB, dBm, and vu.

Description : Kelvin bridges are well suited for what type of measurements?

Last Answer : Small values of resistances

Description : When you are measuring a component using a bridge, what is the most common cause of inaccurate measurements?

Last Answer : The capacitive and inductive characteristics of the test leads.

Description : Power measurements performed with calorimeters are based on what three variables?

Last Answer : Temperature, mass, and time.

Description : For power measurements, what advantage does an electronic wattmeter have over an electrodynamic wattmeter?

Last Answer : Electronic wattmeters are capable of measuring high-fequency signals.

Description : When is an optical power meter measurement recommended for conducting field measurements on installed optical fiber cables or cable plants?

Last Answer : When an installed optical fiber cable or cable plant is less than 50 meters in length.

Description : Why do end users perform fiber geometry measurements in the laboratory?

Last Answer : To reduce system attenuation and coupling loss resulting from poor fiber fabrication.

Description : What two properties of the launch condition may affect multimode fiber attenuation measurements?

Last Answer : . Launch spot size and angular distribution.

Description : List the fiber geometrical measurements performed in the laboratory.

Last Answer : Cladding diameter, core diameter, numerical aperture, and mode field diameter.

Description : Prior to substituting a diode, what measurements should you take to determine its condition?

Last Answer : Voltages and resistances.

Description : What are the advantages of connecting ammeters in parallel when performing current measurements?

Last Answer : Decreased internal meter resistance, greater accuracy, and greater current range.

Description : If an ac voltmeter is connected between the S2 and S3 windings on a TX, at what two rotor positions should the voltmeter read maximum voltage?

Last Answer : . 150º and 330º

Description : Why does using ac vice dc bias voltage result in a stronger output signal?

Last Answer : Because an ac bias voltage of the proper frequency and level places the input signal away from both steps in the magnetism curve. The result is two undistorted output signals that are combined into one strong output.

Description : What are three advantages of adding an ac bias voltage to the input signal instead of adding a fixed dc bias voltage?

Last Answer : a. Reproduces a stronger output signal. b. Greatly improves the SNR. c. Greatly reduces the natural tape hiss.

Description : Why does adding dc vice ac bias voltage to the input signal result in a poor signal-to-noise ratio (SNR)?

Last Answer : With dc bias, the SNR is poor because only a small portion of the magnetism curve is straight enough to use, thus the output signal is weak compared with the natural tape hiss.

Description : If the mu of a tube is 85 and the signal at the control grid is 4 volts ac, the plate voltage will vary by what amount?

Last Answer : 340 volts.

Description : The plate voltage of a tube will vary 126 volts when a 3-volt ac signal is applied to the control grid. What is the gain of this tube?

Last Answer : 42.

Description : An ac voltage is applied across a diode. The tube will conduct when

Last Answer : Positive.

Description : What component causes a generator to produce dc voltage rather than ac voltage at its output terminals?

Last Answer : A commutator

Description : Air gap readings should be periodicly taken for electrical generation equipment. The best tool to use to take these measurements is a ___________. A. cloth (non-metalic) tape measure B. dial indicator C. inside micrometer D. tapered, long blade, feeler gage

Last Answer : Answer: D

Description : Which of the following refers to the degree to which a transportation mode can provide equipment and conditions appropriate for moving specific kinds of goods? A)Reliability. B)Capability C)Capacity D)Accessibility E)Frequency

Last Answer : B)Capability

Description : Why PM-MC meters can't be used for AC measurements?

Last Answer : It wont work for AC measurements. Not designed for ACapplication

Description : Refers to an ac bridge for measuring the inductance and Q of an inductor in terms of resistance, frequency and a standard capacitance.

Last Answer : hay bridge

Description : Which of the following would least quality as an essential aspect of the process of learning? Options: A) Adequate readiness B) Response to stimulation C) Insight into means-end relationship D) The reinforcement of response

Last Answer : C) Insight into means-end relationship 

Description : The Doppler effect causes a change in what aspect of rf energy that strikes a moving object?

Last Answer : Frequency.

Description : What calibration label is used when actual measurement values must be known to use the test equipment?

Last Answer : CALIBRATED—REFER TO REPORT.

Description : What test equipment is designed to generate, modify, or measure a range of parameters of electronic functions of a specific nature required to test a single system or equipment?

Last Answer : Special-purpose electronic test equipment.

Description : Name the two classes of test equipment.

Last Answer : General-purpose electronic test equipment (GPETE) and special-purpose electronic test equipment (SPETE).

Description : What system is currently used by all branches of the military to identify test equipment?

Last Answer : Joint Electronics Type Designation System (JETDS).