Air preheater is not used as a waste heat recovery system in a____.
a) Boiler b) billet Reheating Furnace
c) Heat treatment furnace d) compressor

1 Answer

Answer :

compressor

Related questions

Description : Recuperated is used mainly as a waste heat recovery system in a ____. a) Boiler b) Billet Reheating Furnace c) Compressor d) None of the above

Last Answer : Billet Reheating Furnace

Description : Nellore to medium temperature waste heat recovery system the most suitable device is ------ a) Economizer b) Heat wheels c) Air preheater d) Recuperate d) Carbonate

Last Answer : Heat wheels

Description : In a low to medium temperature waste heat recovery system which of the device is most suitable a) Economiser b) Heat wheels c) air preheater d) Recuperator

Last Answer : Heat wheels

Description : Recovery of waste heat from hot fluid to fluid is called: a) thermo compressor b) waste heat recovery boiler c) heat Pump d) economizer

Last Answer : heat Pump

Description : Recovery of heat from dryer exhaust air is a typical application of: a) Waste heat recovery boiler b) Heat pump c) Heat wheel d) Economizer

Last Answer : Heat wheel

Description : Design of waste heat boiler for recovery of waste heat from furnace gases depends upon the (A) Quantity & temperature of waste gas (B) Dust concentration & nature of dust in waste gas (C) Corrosive nature of the waste gas (D) All (A), (B) and (C)

Last Answer : (B) Dust concentration & nature of dust in waste gas

Description : Which of the following is not a continuous waste heat recovery equipment from the flue gases going out of furnace? (A) Economiser (B) Regenerator (C) Ceramic recuperator (D) Waste heat boiler

Last Answer : (B) Regenerator

Description : Which of the following furnaces will have maximum thermal efficiency? (A) Soaking pits (B) Walking beam reheating furnace (C) Boiler furnace (D) Rotary kilns

Last Answer : (C) Boiler furnace

Description : Which is the most thermally efficient furnace? (A) Reheating furnace (B) Reverberatory furnace (C) Rotary kilns (D) Boiler furnace

Last Answer : (D) Boiler furnace

Description : Which of the following is not a recuperative furnace? (A) Soaking pit (B) Reheating furnace (C) Steam boiler (D) Coke oven

Last Answer : (D) Coke oven

Description : Waste heat from the outgoing flue gases in a thermal power plant is recovered by a/an (A) Economiser (B) Steam superheater (C) Air preheater (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : In which of the waste heat recovery equipment, the flow of flue gas and air is alternately reversed after a fixed interval of time? (A) Recuperator (B) Regenerator (C) Waste heat boiler (D) None of these

Last Answer : (B) Regenerator

Description : Which of the following is a heat treatment furnace? (A) Muffle furnace (B) Annealing furnace (C) Reheating furnace (D) Rotary kiln

Last Answer : (B) Annealing furnace

Description : Regenerator is widely used in: a) Reheating Furnaces b) heat treatment furnaces c) Baking Ovens d) glass melting furnaces

Last Answer : glass melting furnaces

Description : Which is an example of closed system? (A) Air compressor (B) Liquid cooling system of an automobile (C) Boiler (D) None of these

Last Answer : (B) Liquid cooling system of an automobile

Description : Thermal efficiency of furnaces can be improved by (A) Waste heat recovery from flue gas (B) Minimising heat losses from furnace walls (C) Maintaining proper draught (D) All (A), (B) and (C

Last Answer : (D) All (A), (B) and (C

Description : Regenerators are used for waste heat recovery in (A) By-product coke ovens (B) Beehive coke oven (C) Blast furnace stoves (D) Soaking pits

Last Answer : (A) By-product coke ovens

Description : Heat transfer rate to the stock/charge in the furnace does not depend upon the (A) Emissivity of the refractory walls (B) Size of the furnace (C) Use of waste heat recovery equipments (D) Thickness of the stock

Last Answer : (C) Use of waste heat recovery equipments

Description : Pitch creosote mixture (PCM) as compared to furnace oil is a better fuel, because its (A) Emissivity factor is higher (B) Sulphur content is lower (C) Flue gas has lower dew point thereby facilitating more waste heat recovery (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Thermo-compressor is commonly used for a) compressing hot air b) flash steam recovery c) distillation d) reverse compression of CO2

Last Answer : flash steam recovery

Description : A waste heat recovery system in industrial process has been key to reduce ....... Consumption. a) Coal b) Fuel c) Biogas d) Oil

Last Answer : Fuel

Description : In industrial operations fluids with temperature less than __________ are set as the limit for waste heat recovery because of the risk of condensation of corrosive liquids a. 80C b. 100C c. 120C d. 200C

Last Answer : 100C

Description : Calculate the recoverable waste heat (Q, in kCal/hour) from flue gases using the followingparameters: V (flow rate of the substance) 2000 m3/hr r (density of the flue gas): 0.9 kg/m3 Cp (specific heat ... (temperature difference): 120 oC h (recovery factor): 50% a. 21600 b. 43200 c. 25600 d. 34000

Last Answer : 21600

Description : A high temperature waste heat recovery unit consists of recovering waste heat at temperaturesgreater than _______. a) 200 °C b) 500 °C c) 300 °C d) 400 °C

Last Answer : 400 °C

Description : What are the benefits or the advantages of waste heat recovery units (WHRU)? a) Reduced Pollution b) Reduced equipment sizes c) Reduced auxiliary energy consumption. d) All of the above

Last Answer : All of the above

Description : The waste heat recovery unit (WHRU) is a tool involved in _______. a) Regeneration b) Cogeneration c) Both ‘a’ and ‘b’ d) None of the above

Last Answer : Cogeneration

Description : A waste heat recovery unit (WHRU) is an_________ that transfers heat from process outputs at high temperature to another part of the process for some purpose, usually increased efficiency. a) Energy recovery heat exchanger b) Energy recovery heat diffuser c) Both ‘a’ and ‘b’ d) None of the above

Last Answer : Energy recovery heat exchanger

Description : A waste heat recovery unit is an energy recovery heat exchanger that transfers heat from process outputs at ........ a) High temperature b) Medium temperature c) Low temperature d) Both a & b

Last Answer : High temperature

Description : One of the key areas for ....... energy saving in existing systems is waste heat recovery. a) Potential b) Kinetic c) Thermal d) Electrical

Last Answer : Potential

Description : Techniques of waste heat recovery ....... a) Direct contact condensation b) Indirect contact condensation c) Transport membrane condensation d) All of the above

Last Answer : All of the above

Description : A major advantage of waste heat recovery in industry is a) Reduction in pollution c) Increase efficiency d) None of the above

Last Answer : Reduction in pollution

Description : Major advantage of waste heat recovery in industry is: a) Reduction in pollution b) increase in efficiency c) Both a & b d) none of the above

Last Answer : Both a & b

Description : In regenerative air preheater (as practised in heating of coke ovens), the heat is transferred (A) Through a metallic wall (B) By direct contact of hot flue gas with air (C) By ... material (like chequor bricks) and then heating the air from this hot material (D) None of these

Last Answer : (C) By heating an intermediate material (like chequor bricks) and then heating the air from this hot material

Description : Low water in boiler drum is unsafe because it may result in overheating of water tubes in furnace. Why it is unsafe to have high water condition in boiler drum ?

Last Answer : High drum level does not allow steam separation to be effective and some water can be carried over with steam which is not desirable for steam turbine.

Description : An example of indirectly heated furnace is the (A) Soaking pit (B) Muffle furnace (C) Reheating furnace (D) None of these

Last Answer : (B) Muffle furnace

Description : Neutral atmosphere is maintained in a/an __________ furnace. (A) Cold rolled steel coil annealing (B) Open hearth (C) Soaking pit (D) Walking beam reheating

Last Answer : (A) Cold rolled steel coil annealing

Description : The thermal efficiency of a steel slab reheating furnace (walking beam type) may be about __________ percent. (A) 15 (B) 40 (C) 70 (D) 85

Last Answer : (B) 40

Description : Which furnace employs preheating, heating and soaking zones? (A) Soaking pit (B) Reheating furnace (C) Open hearth furnace (D) Cupola

Last Answer : (B) Reheating furnace

Description : __________ is an indirectly heated furnace. (A) Open hearth furnace (B) Muffle furnace (C) Soaking pit (D) Reheating furnace

Last Answer : (B) Muffle furnace

Description : Reheating furnace (pusher type) is used for heating (A) Ingots (B) Slabs (C) Steel coils (D) Steel sheets

Last Answer : (B) Slabs

Description : Which of the following is a periodic furnace? (A) Tunnel kiln (B) Rotary kiln (C) Soaking pit (D) Reheating furnace

Last Answer : (C) Soaking pit

Description : Which of the following is a directly fired intermittent furnace? (A) Walking beam reheating furnace (B) Reverberatory furnace (C) Tower furnace (D) Tunnel kiln

Last Answer : (B) Reverberatory furnace

Description : Which of the following is a batch furnace? (A) Cupola (B) Reheating furnace (C) Glass tank furnace (D) None of these

Last Answer : (A) Cupola

Description : An improved and fuel efficient version of the pusher type reheating furnace is the __________ furnace. (A) Walking beam (B) Shaft (C) Tunnel (D) Rotary hearth

Last Answer : (A) Walking beam

Description : The heating capacity of continuous reheating furnace depends upon the (A) Hearth area and furnace temperature (B) Emissivity of the stock (C) Ratio of wall surface to stock surface (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Economizer is provided to utilize the flue gas heat for ___ a) preheating the boiler feed water b) preheating the stock c) preheating the combustion air d) preheating fuel

Last Answer : preheating the boiler feed water

Description : Heat transfer takes place through a liquid medium surrounding the submerged material under heating, in case of a/an (A) Blast furnace (B) Steam boiler (C) Salt bath furnace (D) Annealing furnace

Last Answer : (C) Salt bath furnace

Description : Heat transfer to the water wall in a high pressure water wall type boiler furnace is mainly by (A) Conduction (B) Convection (C) Radiation (D) Both 'a' & 'b'

Last Answer : Option C