Even though heat transfer co-efficient in boiling liquids is large, use of
fins is advantageous, when the entire surface is exposed to __________
boiling.
(A) Film
(B) Nucleate
(C) Transition
(D) All modes of

1 Answer

Answer :

Option A

Related questions

Description : Pick out the wrong statement. (A) Superheated steam is preferably not used for process heating because of its low heat transfer film co-efficient (B) In a shell and tube heat exchanger ... surface heat exchangers, when the direction of fluid flow is parallel to the axis of the tube

Last Answer : (C) S.I. unit of fouling factor is Watt/m2 .°K

Description : Pick out the wrong statement. (A) 'Solvates' are chemical compounds formed by solute with their solvents. When water is the solvent, then it is called a 'hydrate' (B) In heat exchanger ... vertical evaporators, area of central downtake is about 50 to 100% of the total tube cross-sectional area

Last Answer : (C) Heat transfer co-efficient during nucleate boiling is not influenced by the agitation imparted

Description : Pick out the wrong statement about nucleate boiling. (A) Bubble generation is by expansion of entrapped gas/vapour at small cavities in the surface (B) Surface temperature is greater than the saturation ... less than that in film boiling (D) The temperature is less than that of film boiling

Last Answer : (D) The temperature is less than that of film boiling

Description : When vaporisation takes place through a blanketting film of gas, the phenomenon is termed as __________ boiling. (A) Pool (B) Nucleate (C) Transition (D) Film

Last Answer : (D) Film

Description : The main purpose of providing fins on heat transfer surface is to increase the (A) Temperature gradient (B) Mechanical strength of the equipment (C) Heat transfer area (D) Heat transfer co-efficient

Last Answer : (C) Heat transfer area

Description : Pick out the wrong statement. (A) In case of heat transfer by purely forced convection, GR /Re 2 ≤ 1 (B) The equivalent diameter of heat transfer for a duct of ... nucleate boiling depends basically on the ease with which the bubbles are formed and detached from the heating surface

Last Answer : (B) The equivalent diameter of heat transfer for a duct of square cross￾section (having each side as 'x') is equal to 4x

Description : When vaporisation takes place directly at the heating surface, it is called (A) Film boiling (B) Nucleate boiling (C) Vapour binding (D) None of these

Last Answer : (B) Nucleate boiling

Description : A thin, flat & square plate measuring 2 m 2 m is freely hanging in ambient air at 25°C. It is exposed to the solar radiation falling on one side of the plate at the rate of 500 W/m2. The plate temperature will ... heat transfer co-efficient is __________ W/m2 °C. (A) 50 (B) 100 (C) 150 (D) 200

Last Answer : (B) 100

Description : Boiling of milk in an open vessel is an example of __________ boiling. (A) Film (B) Sub-cooled (C) Saturated nucleate (D) None of these

Last Answer : (A) Film

Description : Convective heat transfer co-efficient in case of fluid flowing in tubes is not affected by the tube length/diameter ratio, if the flow is in the __________ zone. (A) Laminar (B) Transition (C) Both 'a' & 'b' (D) Highly turbulent

Last Answer : (D) Highly turbulent

Description : The left face of a one dimensional slab of thickness 0.2 m is maintained at 80°C and the right face is exposed to air at 30°C. The thermal conductivity of the slab is 1.2 W/m.K and the heat transfer co-efficient from the ... temperature of the right face in °C is (A) 77.2 (B) 71.2 (C) 63.8 (D) 48.7

Last Answer : (D) 48.7

Description : In case of __________ boiling, the bubbles formed on a submerged hot surface get absorbed in the mass of the liquid. (A) Nucleate (B) Pool (C) Low pressure (D) None of these

Last Answer : (B) Pool

Description : In case of __________ boiling, the liquid temperature is below the saturation temperature and the boiling takes place in the vicinity of the heated surface. (A) Nucleate (B) Local (C) Pool (D) Saturated

Last Answer : (B) Local

Description : Heat transfer co-efficient (h1 ) for liquids increases with (A) Increasing temperature (B) Decreasing temperature (C) Decreasing Reynolds number (D) None of these

Last Answer : (A) Increasing temperature

Description : Mass transfer co-efficient is directly proportional to DAB 0.5 , according to __________ theory. (A) Penetration (B) Surface renewal (C) Film (D) None of these

Last Answer : (A) Penetration

Description : Mass transfer co-efficient is directly proportional to DAB according to the __________ theory. (A) Film (B) Penetration (C) Surface-renewal (D) None of these

Last Answer : (A) Film

Description : Calculation of mass transfer co-efficient is mostly/normally done using __________ theory. (A) Surface renewal (B) Film (C) Penetration (D) None of these

Last Answer : (B) Film

Description : Controlling heat transfer film co-efficient is the one, which offers __________ resistance to heat transfer. (A) No (B) The least (C) The largest (D) Lower

Last Answer : (C) The largest

Description : The heat transfer co-efficient in film type condensation is __________ that for dropwise condensation. (A) Greater than (B) Lower than (C) Is same as (D) Half

Last Answer : (B) Lower than

Description : Which of the following situations can be approximated to a steady state heat transfer system? (A) A red hot steel slab (having outside surface temperature as 1300°C) exposed to the atmospheric air at ... flowing at the rate of 6 Kg/minute through a copper pipe exposed to atmospheric air at 35°C

Last Answer : (B) 10 kg of dry saturated steam at 8 kgf/cm2 flowing through a short length of stainless steel pipe exposed to atmospheric air at 35°C

Description : Leidenfrost point is a term concerned with the (A) Condensation of the saturated vapor on a cold surface (B) Concentration of a corrosive solution by evaporation (C) Heat transfer between two highly viscous liquids (D) Boiling of a liquid on a hot surface

Last Answer : (D) Boiling of a liquid on a hot surface

Description : Log mean temperature difference (LMTD) cannot be used, if (A) Heat transfer co-efficient over the entire heat exchanger is not constant (B) There exists an unsteady state (C) The heat capacity is not constant and there is a phase change (D) None of these

Last Answer : (D) None of these

Description : The average heat transfer co-efficient over the entire length of the plate (ha ) and the local heat transfer co-efficient (hL ), in case of heat transfer over a flat plate in laminar zone is related as (A) ha = 0.8hL (B) ha = 2hL (C) ha = hL (D) ha = 5hL

Last Answer : (B) ha = 2hL

Description : Heat exchangers operating, when the asymptotic range is reached, (A) Provide very large heat transfer co-efficient (B) Results in making part of the heating surface inactive (C) Results in abruptly increased velocity (D) None of these

Last Answer : (B) Results in making part of the heating surface inactive

Description : . A dilute aqueous solution is to be concentrated in an evaporator system. High pressure steam is available. Multiple effect evaporator system is employed, because (A) Total heat transfer area of ... in a single effect is much lower than that in any effect in a multi-effect system

Last Answer : (B) Total amount of vapor produced per Kg of feed steam in a multiple effect system is much higher than in a single effect

Description : As the difference between the wall temperature and bulk temperature increases, the boiling heat transfer co-efficient (A) Continues to increase (B) Continues to decrease (C) Goes through a minimum (D) Goes through a maximum

Last Answer : (C) Goes through a minimum

Description : The burnout heat flux in the nucleate boiling regime is not a function of the (A) Liquid density (B) Vapour density (C) Temperature difference (D) Heat of evaporation

Last Answer : (B) Vapour density

Description : Pick out the wrong statement. (A) The condensing film co-efficient is about 3 times lower for vertical condenser as compared to the equivalent horizontal condenser for identical situation ( ... in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Last Answer : (D) Overall heat transfer co-efficient in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Description : If h1 = inner film co-efficient and /h2 = outer film co-efficient, then the overall heat transfer co-efficient is (A) Always less than h1 (B) Always between h1 and h2 (C) Always higher than h2 (D) Dependent on metal resistance

Last Answer : (B) Always between h1 and h2

Description : Extended heat transfer surface like fins are used to increase the heat transfer rate. Fin efficiency is defined as the ratio of heat transferred across the fin surface to the theoretical heat transfer ... (C) Temperature of the fin end (D) Constant temperature equal to that of the base

Last Answer : (D) Constant temperature equal to that of the base

Description : Film boiling is usually not desired in commercial equipments, because (A) The heat transfer rate is low in view of the large temperature drop (B) It is difficult to maintain (C) It is not economic (D) None of these

Last Answer : (A) The heat transfer rate is low in view of the large temperature drop

Description : Pick out the wrong statement. (A) In a first order reaction, A → products; the reaction becomes slower as it proceeds, because the concentration of A decreases and the rate is proportional to the concentration ... irreversible reaction, A + B → 2C is k.CA .CB , then the reaction is always elementary

Last Answer : (C) According to the penetration theory, the mass transfer co-efficient decreases, if the exposure time of an eddy to the solute decreases

Description : Is it ever advantageous to use shells in series even though it may not be necessary?

Last Answer : Usually you design for the least number of shells for an item. However, there are times when it is more economical to add a shell in series to the minimum configuration. This will be when ... velocity and heat transfer because of the smaller flow area in the smaller exchangers that are required.

Description : Extremely large or small volumes of fluids are generally best routed through the shell side of a shell and tube heat exchanger, because of the (A) Less corrosion problems (B) Flexibility possible in the baffle arrangement (C) Low pressure drop (D) High heat transfer co-efficient

Last Answer : (B) Flexibility possible in the baffle arrangement

Description : In a shell and tube heat exchanger, floating head is used for (A) Large temperature differentials (B) High heat transfer co-efficient (C) Low pressure drop (D) Less corrosion of tubes

Last Answer : (A) Large temperature differentials

Description : __________ involves combining and co -ordinating two or more modes of transportation to take advantage of benefits offered by different types of carriers. A)Intermodal transportation B)Physical distribution C)Containerised movement D)Efficient and effective transportation E)Freight forwarding

Last Answer : A)Intermodal transportation

Description : Which of the following parameters is increased by use of finned tube in a multipass shell and tube heat exchanger? (A) Tube side pressure drop and the heat transfer rate (B) Convective heat transfer co-efficient (C) Effective tube surface area for convective heat transfer (D) All (A) (B) and (C)

Last Answer : (D) All (A) (B) and (C)

Description : . The inner wall of a furnace is at a temperature of 700°C. The composite wall is made of two substances, 10 and 20 cm thick with thermal conductivities of 0.05 and 0.1 W.m-1.°C-1 respectively. The ambient air is at 30°C ... from the outer surface in W.m-2 is (A) 165.4 (B) 167.5 (C) 172.5 (D) 175

Last Answer : (A) 165.4

Description : Fouling factor for a heat exchanger is given by (where, U1 = heat transfer co-efficient of dirty surface U2 = heat transfer co-efficient of clean surface). (A) U1 - U2 (B) 1/U1 - 1/U2 (C) 1/U2 - 1/U1 (D) U2 - U1

Last Answer : (B) 1/U1 - 1/U2

Description : Steam side heat transfer co-efficient in an evaporator is in the range of __________ kcal/hr.m2°C. (A) 10-50 (B) 100-500 (C) 1000-1500 (D) 5000-15000

Last Answer : (D) 5000-15000

Description : The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by __________ times, when the number of tube passes is increased to 8. (A) 2 0.8 (B) 4 0.8 (C) 4 0.4 (D) 2 0.4

Last Answer : (B) 4 0.8

Description : Nucleate boiling is promoted (A) On polished surfaces (B) On rough surfaces (C) In the absence of agitation (D) None of these

Last Answer : (B) On rough surfaces

Description : Pick out the wrong statement. (A) Bubble size increases with the dynamic viscosity of the liquid in case of nucleate pool boiling (B) Thermal conductivity of a dry material is more than ... in kg/hr in an evaporator (D) Vaporisation of organic substances in evaporator mostly causes foam formation

Last Answer : (B) Thermal conductivity of a dry material is more than that of the damp material

Description : Mass transfer co-efficient (K) and diffusivity (D) are related according to film theory as (A) K ∝ D (B) K ∝√D (C) K ∝ D1.5 (D) K ∝ D

Last Answer : (A) K ∝ D

Description : The overall mass transfer co-efficient for the absorption of SO2 in air with dilute NaOH solution can be increased substantially by (A) Increasing the gas film co-efficient (B) Increasing the liquid film co-efficient (C) Increasing the total pressure (D) Decreasing the total pressure

Last Answer : (A) Increasing the gas film co-efficient

Description : The Reynolds number of the liquid was increased 100 fold for a laminar falling film used for gas-liquid contacting. Assuming penetrating theory is applicable, the fold increase in the mass transfer co-efficient (Kc ) for the same system is. (A) 100 (B) 10 (C) 5 (D) 1

Last Answer : (B) 10

Description : Pick out the correct statement about the condensation. (A) Filmwise condensation gives a lower heat transfer rate than the dropwise condensation (B) Suitable coating or vapour additive is used to promote film ... place on it (D) Reynolds number of condensing liquid is based on its mass flow rate

Last Answer : (B) Suitable coating or vapour additive is used to promote film wise condensation

Description : Viscous & heat sensitive liquids are concentrated in __________ evaporators. (A) Open pan (B) Long tube (C) Agitated film (D) None of these

Last Answer : (C) Agitated film

Description : Finned tube heat exchangers (A) Give larger area per tube (B) Use metal fins of low thermal conductivity (C) Facilitate very large temperature drop through tube wall (D) Are used for smaller heat load

Last Answer : (A) Give larger area per tube