Why earth fault current of generator should not be reduced below 5A? 

1 Answer

Answer :

To limit over voltage due to neutral shift.  

Related questions

Description : How generator earth fault relay works? 

Last Answer : 100% earth fault relay works on the principle involving monitoring of neutral side and line side components of 3rd harmonic voltages produced by generator in service. Since the machine is grounded with ... be detected by VL3 neutral displacement module, which is tuned to find frequency.   

Description :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: -  a) 300A b) 200A c) 150A d) 37.5A

Last Answer :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: - 37.5A

Description : Find the magnetic field intensity due to an infinite sheet of current 5A and charge density of 12j units in the positive y direction and the z component is below the sheet. a) 6 b) 0 c) -6 d) 60k

Last Answer : c) -6

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : Where fault level is more, whether in generator bus duct or UT bus duct? Why?

Last Answer : Fault level is more in UT bus duct. Because the fault currents fed by the both generator and GT adds up within UT bus duct in case there is a fault in UT bus duct. 

Description : Purpose of Over current & earth fault relay; type- CAG  

Last Answer : This relays are designed for instantaneous phase or earth fault protection and instantaneous high set over current protection.; A standard hinged-armature unit forms the basic movement for this relay. It consists an ... to the end of the core while the other arm to operate a set of contacts.  

Description : Purpose of Directional inverse Over current & earth fault relay; type- CDD

Last Answer : Directional phase or earth fault protection of ring-mains, parallel transformers, transformer feeders, parallel feeders etc., employing the time graded principle.; This relay comprises an inductive ... induction disc unit. The directional unit is normally provided with voltage polarising coils. 

Description : The zero sequence current of a generator for line to ground fault is j 2.4 p.u. The current through the neutral during the fault is (a) j 0.8 p.u (b) j 2.4 p.u. (c) j 0.24 p.u. (d) j 7.2 p.u. 

Last Answer : j7.2

Description : The steady-state fault current during a 3 phase terminal fault on a generator is limited by: (1) Transient reactance of the generator (2) Sub-transient reactance of the generator (3) Synchronous reactance of the generator (4) DC off—set during the instant of the fault

Last Answer : 1

Description : For a fault at the terminals of a synchronous generator, the fault current is maximum for a  A) 3-phase fault B) 3-phase to ground fault C) Line to ground fault D) Line to line fault

Last Answer : C) Line to ground fault

Description : An open-circuit fault between the pressure switch and the 'annunciator module' shown in the illustration would cause the alarm circuit to react in the same manner as if ___________. EL-0094 A. 3.5 ... below switch setting C. 50 PSI were applied to the 'setpoint module' D. the pressure switch closed

Last Answer : Answer: B

Description : When earth fault occurs: a) voltage potential at the earth mat increases due to grounding b) voltage potential at the earth mat decreases due to grounding c) voltage potential at the earth mat remains zero irrespective of fault d) none of the above

Last Answer : Ans: A

Description : Why core balance CT is preferred over residual connected CT’s to sense earth fault in 6.6 kV feeders?

Last Answer : a) To avoid relay mal-operation due to CT saturation b) Better sensitivity is got. c) High pickup and TMS avoided in IDMT earth fault relay. 

Description : Why 2 types of earth fault relays in 6.6 kV side of transformers?

Last Answer : I – Trips 6.6 kV breakers only. It gives primary protection for 6.6 kV bus bars. I1 – Trips the both HT and LT breakers. It acts as a backup to ref and also acts as backup to bus bar earthfault relay. 

Description : Will rotor earth fault relay operate for earth fault in main exciter winding or RCU Diode Bridge also? 

Last Answer : Yes. 

Description : Why not high resistance for earth fault than using grounding transformer & resistor 0.45 ohms?

Last Answer : It is mechanically unwide. Difficult to manufacture.  

Description : Moisture absorbed in the windings or condensed on the surface of electrical machinery insulation ________. A. is good for long term preserving since most insulation is organic and contains some amount B. ... D. reduces the amount of current supplied or drawn by the machine so horsepower is limited

Last Answer : Answer: B

Description : A circular coil of `20turns` and radius `10cm` carries a current of `5A`. It is placed in a uniform magnetic field of `0*10T`. Find the torque acting

Last Answer : A circular coil of `20turns` and radius `10cm` carries a current of `5A`. It is placed in a uniform magnetic ... Nm B. 3.14 Nm C. 0.314 Nm D. zero

Description : Six resistance are connected as shown in figure. If total current flowing is `0.5A`, then the potrential difference `V_(A)-V_(B)` is

Last Answer : Six resistance are connected as shown in figure. If total current flowing is `0.5A`, then the potrential difference `V_(A) ... V B. 6 V C. 2 V D. 4 V

Description : In the circuit shown the cell is ideal. The codil has an inductance of 2H and will blow when the current through it reaches 5a. The switch is closed a

Last Answer : In the circuit shown the cell is ideal. The codil has an inductance of 2H and will blow when the ... Find the time (in second)n when fuse will blow.

Description : Calculate the flux density due to a circular conductor of radius 100nm and current 5A in air. a) 10 b) 100 c) 0.1 d) 1

Last Answer : a) 10

Description : Find the Lorentz force due to a conductor of length 2m carrying a current of 1.5A and magnetic flux density of 12 units. a) 24 b) 36 c) 32 d) 45

Last Answer : c) 32

Description : Find the power of an inductor of 5H and current 4.5A after 2 seconds. a) 25.31 b) 50.62 c) 102.4 d) 204.8

Last Answer : a) 25.31

Description : Find the magnetic field intensity due to a solenoid of length 12cm having 30 turns and current of 1.5A. a) 250 b) 325 c) 175 d) 375

Last Answer : d) 375

Description : Find the magnetic field intensity due to an infinite sheet of current 5A and charge density of 12j units in the positive y direction and the z component is above the sheet. a) -6 b) 12k c) 60 d) 6

Last Answer : d) 6

Description : Find the force due to a current element of length 2cm and flux density of 12 tesla. The current through the element will be 5A. a) 1 N b) 1.2 N c) 1.4 N d) 1.6 N

Last Answer : b) 1.2 N

Description : Find the magnetic flux density when a point from a finite current length element of current 0.5A and radius 100nm. a) 0 b) 0.5 c) 1 d) 2

Last Answer : c) 1

Description : Find the force on a conductor of length 12m and magnetic flux density 20 units when a current of 0.5A is flowing through it. a) 60 b) 120 c) 180 d) 200

Last Answer : b) 120

Description : The current in the circuit shown in figure - What will be the current in the circuit? a. 1/45A b. 1/10A c. 1/5A d. 5A

Last Answer : b. 1/10A

Description : A coil of 500 turns is linked with a flux of 25 mwb, when carries a current of 12.5A. Calculate the value of self-inductance.

Last Answer : Ans: Self-Inductance: L = NΦ /I = 500 × 25 × 10-3 / 12.5 = 1 H

Description : An ammeter has a current change of 0-5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of  A) 0.8 ohm in series with the meter B) ... series with the meter C) 0.04 ohm in parallel with the meter D) 0.05 ohm in parallel with the meter

Last Answer : An ammeter has a current change of 0—5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of 0.05 ohm in parallel with the meter

Description : A large transformer operating at no load draws an exciting current Io of 5A, when the primary is connected to a 120 V, 60 Hz source. From a wattmeter test, it is known that iron losses are equal to 180 W. Calculate ... power absorbed by the core.  (A) 600 var (B) 572 var (C) 180 var (D) 360 var 

Last Answer : 572var

Description : Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator:

Last Answer : Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator: inter turn fault protection

Description : The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above

Last Answer : (b) internal short-circuits

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Description : Will main generator differential relay pick up for generator earth faults? 

Last Answer : No earth fault current limited to 5A, while differential setting is 10%. 

Description : Damp armature windings in a D.C. motor may lead to ____________. A. reduced voltage B. reduced current C. increased resistance D. overheating

Last Answer : Answer: D

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : If many turns of an alternating current coil for a contactor become short circuited, the coil _____________. A. will continue to operate B. will probably burn out immediately C. will operate on reduced current D. temperature will drop

Last Answer : Answer: B

Description : If many turns of an alternating current coil for a contactor become short circuited, the coil _____________. A. temperature will drop B. will probably burn out immediately C. will continue to operate D. will operate on reduced current

Last Answer : Answer: B

Description : Reduced voltage applied to a motor during the starting period will _____________. A. result in decreased acceleration time only B. lower the starting current and increase accelerating time C. cause a greater starting torque D. increase the starting current and pump capacity

Last Answer : Answer: B

Description : Across-the-line starters are used with AC motors to provide _____________. A. reduced starting current B. regulated starting current C. high starting torque D. controlled starting acceleration

Last Answer : Answer: C

Description : An across-the-line starter is typically used for which of the following applications? A. Reduced-current starting of large motors B. Low torque starting of small motors C. Low resistance starting of DC motors D. Full-voltage starting of motors

Last Answer : Answer: D

Description : Why current reduced after gassing? 

Last Answer : Excessive gassing shortens the life of battery by scouring the active materials at the surface of the plates. 

Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip

Last Answer : Answer: D

Description : In the schematic diagram of the DC compound generator shown in the illustration, the positive ammeter reading is 500 amps and the negative ammeter reading is 475 amps. What is the current flow through the neutral bus? EL-0037 A. 0 amp B. 12.5 amp C. 25 amp D. 975 amp

Last Answer : Answer: C

Description : As shown in the illustration, the generator field is excited with DC current provided by ____________. EL-0016 A. conductors '1', '2' and '3' B. inductor 'L1' C. rectifier 'CR1' D. winding 'S-2'

Last Answer : Answer: C