What maximum load would you place on a right angle coupler?

1 Answer

Answer :

630kg (or 630kgf or 6.25kN)

Related questions

Description : What is the height of the base lift (kicker lift) on a typical tube and coupler scaffold? a. 225mm (9 inches) b. 300mm (12 inches) c. 150mm (6 inches) d. 100mm (4 inches)

Last Answer : c. 150mm (6 inches

Description : What is the maximum load you would lift with a gin wheel?

Last Answer : 50kg

Description : At what angle must zig zag bracing be installed? a. 35-55 degree b. 35-60 degree c. 25-45 degree d. 35-70 degree

Last Answer : a. 35-55 degree

Description : What is the maximum height allowed between ladder landings?

Last Answer : 6m (or 3 lifts)

Description : What is the maximum distance that bracing can be installed from a node point on a scaffold? a. 200mm (8 inches) b. 300mm (12 inches) c. 150mm (6 inches) d. 250mm (10 inches)

Last Answer : b. 300mm (12 inches)

Description : What is the maximum number of open bays if transverse zig zag bracing is installed along the width of a birdcage scaffold? a. Four b. Three c. Five d. Six

Last Answer : b. Three

Description : The travel distance to an exit point on a working platform must be no more than? a. 7.4m b. 45m c. 15m d. 60m

Last Answer : c. 15m

Description : The vertical distance clearance between the bottoms of the toe board? a. 0mm (0 inch) b. 6mm ( ¼ inch) c. 3mm ( 1/8 inch)

Last Answer : b. 6mm ( ¼ inch)

Description : The width of a scaffold platform or walkways must be at least? a. 3 planks 675mm (27 inches) b. 2 planks 450mm (18 inches) c. 5 planks 1,125mm (45 inches) d. 4 planks 900mm (30 inches)

Last Answer : a. 3 planks 675mm (27 inches)

Description : A guardrail system must be fitted if the distance between a working platform a wall is more than? a. 100mm (4 inches) b. 360mm (14 inches) c. 200mm (8 inches) d. 460mm (18 inches)

Last Answer : b. 360mm (14 inches)

Description : The vertical spacing between ties must be no more than? a. 8m (26 feet) b. 10m (33 feet) c. 12m (39 feet) d. 6m (20 feet)

Last Answer : a. 8m (26 feet)

Description : hat is the horizontal spacing between tie? a. No more than 5m (16 feet) b. No more than 9m (30 feet) c. No more than 7m (23 feet) d. No more than 38m (125 feet)

Last Answer : b. No more than 9m (30 feet)

Description : What is the minimum overlap required when splicing bracing? a. 300mm (12 inches) b. 400mm (16 inches) c. 600mm (24 inches) d. 450mm (18 inches)

Last Answer : a. 300mm (12 inches)

Description : Screw jack can be adjusted no more than? a. 300mm (12 inches) of threaded length showing b. 2/3 of the total threaded length showing c. 150mm (6 inches) of threaded length showing d. 1/3 of the total threaded length showing

Last Answer : b. 2/3 of the total threaded length showing

Description : Planks must be overlapped a minimum of ------

Last Answer : 12 inches.

Description : The height of a toe board must be at least? a. 100mm (4 inches) b. 200mm (8 inches) c. 150mm (6 inches) d. 230mm (9 inches)

Last Answer : c. 150mm (6 inches)

Description : What is the main function of bracing? a. To correct any incorrect measurements b. To enable easy inspection of the scaffold c. To make the scaffold square d. To add rigidity to the scaffold

Last Answer : d. To add rigidity to the scaffold

Description : The headroom above a working platform must be at least? a. 1.6m b. 2.1m c. 2m d. 2.6m

Last Answer : c. 2m

Description : The gap between scaffold planks (boards) must be no more than? a. 150mm (6 inches) b. 50mm (2 inches) c. 75mm (3 inches) d. 25mm (1 inch)

Last Answer : d. 25mm (1 inch)

Description : At what height must top rails be fitted above working platform? a. Between 90 cm (35 inches) and 110 cm (43 inches) b. Between 100 cm (39 inches) and 120 cm (47 inches) c. Between 95 cm (38 inches) and 115 cm ( 45 inches) d. Between 105 cm (41 inches)and 125 cm (49 inches)

Last Answer : c. Between 95 cm (38 inches) and 115 cm ( 45 inches)

Description : What is the minimum height an access ladder must extend above the landing?

Last Answer : 1m

Description : Where must longitudinal (façade) bracing be installed on a length whose is greater than its height? a. Every Third post b. Every post c. Every Fifth post d. Every Second post

Last Answer : c. Every Fifth post

Description : What is the main function of bracing? a. To correct any incorrect measurements b. To enable easy inspection of the scaffold c. To make the scaffold square d. To add rigidity to the scaffold

Last Answer : d. To add rigidity to the scaffold

Description : What minimum width of timber would you use as a soleplate?

Last Answer : 220mm (or 225mm, or the width of a scaffold plank)

Description : What is the minimum size of a square baseplate?

Last Answer : 150mm x 150mm (or 225cm2)

Description : Not a reason for the use of an antenna coupler. A. To make the antenna look resistive B. To provide the output amplifier with the correct load impedance C. To discriminate against harmonics D. To prevent re-radiation of the local oscillator

Last Answer : D. To prevent re-radiation of the local oscillator

Description : One ofthe followingis not a reason forthe use of anantenna coupler: a. To make the antenna look resistive b. To provide the output amplifier with the correct load impedance c. To discriminate against harmonics d. To prevent reradiation of the local oscillator

Last Answer : d. To prevent reradiation of the local oscillator

Description : What is a coupler signal ?

Last Answer : coupler signal K.

Description : Which one is an antenna coupling unit? A. Coupler B. Diplexer C. Lecher wire D. Duplexer

Last Answer : B. Diplexer

Description : A component that samples the microwave signal travelling in one direction down to the transmission line A. Isolator B. Combiner C. Directional coupler D. Attenuator

Last Answer : C. Directional coupler

Description : Best choice of transmission line component to couple a coaxial line to a parallel-wire line A. Shorting B. Balun C. Slotted line D. Directional coupler

Last Answer : B. Balun

Description : Referred to as a ferrite device that can be used in lieu of a duplexer to isolate a microwave transmitter and receiver when both are connected to the same antenna. A. Isolator B. Circulator C. Coupler D. Diode.

Last Answer : B. Circulator

Description : A device that connects two dissimilar networks and performs the protocol conversion. A. Gateway B. Coupler C. Transformer D. Converter

Last Answer : A. Gateway

Description : To couple a coaxial line to parallel line, it is better to use a ______. A. Slotted line B. Quarter-wave transformer C. Directional Coupler D. Balun

Last Answer : D. Balun

Description : To connect coaxial line to a parallel-wire _________ is the best to use. A. directional coupler B. quarter-wave transformer C. balun D. slotted line

Last Answer : C. balun

Description : What is an opto-coupler IC?

Last Answer : Opto-coupler IC is a combined package of a photo-emitting device and a photosensing device.Examples for opto-coupler circuit : LED and a photo diode, LED and photo transistor, LED and Darlington. Examples for opto-coupler IC : MCT 2F , MCT 2E .

Description : When a coupler nut is subjected to crushing stress, crushing failure can be avoided if _____ a. crushing stress induced is more than permissible crushing stress in the nut b. permissible crushing ... threads c. crushing stress induced is equal to permissible crushing stress d. all of the above

Last Answer : b. permissible crushing stress is more than crushing stress induced in the threads

Description : Curl cannot be employed in which one of the following? a) Directional coupler b) Magic Tee c) Isolator and Terminator d) Waveguides

Last Answer : d) Waveguides

Description : Bus coupler is very essential in arrangement (a) single bus (b) double bus, double breaker (c) main and transfer bus (d) all of the above

Last Answer : (c) main and transfer bus

Description : What happens to reflected energy that enters a directional coupler that is designed to sample incident energy?

Last Answer : . The reflected energy adds at the absorbent material and is absorbed.

Description : in a directional coupler that is designed to sample the incident energy, what happens to the two portions of the wavefront when they arrive at the pickup probe?

Last Answer : The wavefront portions add.

Description : What is the purpose of the absorbent material in a directional coupler?

Last Answer : Absorb the energy not directed at the pick-up probe and a portion of the overall energy

Description : How far apart are the two holes in a simple directional coupler?

Last Answer : 1/4 wavelength.

Description : What is the primary purpose of a directional coupler?

Last Answer : Sampling energy within a waveguide.

Description : Describe a directional coupler.

Last Answer : A fiber optic coupler that prevents the transfer of power between input fibers.

Description : Which type of optical splitter (Y-coupler or T-coupler) splits only a small amount of power from the input fiber to one of the output fibers?

Last Answer : T-coupler

Description : Which fiber optic component (splice, connector, or coupler) makes a permanent connection in a distributed system?

Last Answer : Splice.

Description : Why is the coupler pressurized with nitrogen?

Last Answer : To aid in heat transfer and prevent corona and arcing

Description : What is the purpose of an antenna coupler

Last Answer : It matches the impedance of an antenna to that of a transmission line at any desired frequency.

Description : What are the tuning modes for the coupler group discussed?

Last Answer : Automatic, semiautomatic, and manual.