Le-chatelier apparatus is used for
[ A ] Fineness test
[ B ] Consistency test
[ C ] Soundness test
[ D ] Compressive strength test

1 Answer

Answer :

[ C ] Soundness test

Related questions

Description : Soundness of cement is tested by (A) Vicat's apparatus (B) Le-chatelier apparatus (C) Compressive strength testing apparatus (D) None of these

Last Answer : Answer: Option B

Description : Le Chatelier apparatus is used to determine which of the following properties for cement A) Soundness* b) Initial setting time c) Compressive strength d) Tensile strength

Last Answer : A) Soundness*

Description : Vicat's apparatus is used for (A) Fineness test (B) Consistency test (C) Setting time test (D) Soundness test

Last Answer : (B) Consistency test

Description : Vicat apparatus is used for (A) Fineness test (B) Consistency test (C) Test for setting time (D) Test for tensile strength

Last Answer : Answer: Option B

Description : Le-Chatelier's device is used for determining the (A) Setting time of cement (B) Soundness of cement (C) Tensile strength of cement (D) Compressive strength of cement

Last Answer : Answer: Option B

Description : Pick up the incorrect statement from the following: (A) The degree of grinding of cement, is called fineness (B) The process of changing cement paste into hard mass, is known as setting of ... (D) The heat generated during chemical reaction of cement with water, is known as heat of hydration

Last Answer : Answer: Option C

Description : The degree of grinding of cement is called (a) Fineness (b) Soundness (c)Impact value (d) Bulking

Last Answer : (a) Fineness

Description : Slump test of concrete is a measure of its (A) Consistency (B) Compressive strength (C) Tensile strength (D) Impact value

Last Answer : (A) Consistency

Description : Slump test of concrete is a measure of its (A) Consistency (B) Compressive strength (C) Tensile strength (D) Impact value

Last Answer : (A) Consistency

Description : Pick up the incorrect statement from the following. For performing compressive strength test of cement (A) Cement and standard sand mortar are used in the ratio of 1 : 3 (B) Water is added at the ... cm 10 cm is used (D) The prepared moulds are kept in a atmosphere of 50% relative humidity

Last Answer : Answer: Option A

Description : For determining the compressive strength test on cement is, the percentage amount of water to be added as (Pa = Percentage of water for required consistency) [ A ] 0.25 Pa + 2.5 [ B ] 0.25 Pa + 3.5 [ C ] 0.35 Pa + 2.5 [ D ] 0.35 Pa + 3.5

Last Answer : [ B ] 0.25 Pa + 3.5

Description : Slump test of concrete is a measure of its [ A ] Consistency [ B ] Compressive strength [ C ] Tensile strength [ D ] Impact value

Last Answer : [ A ] Consistency

Description : Pick out the correct statement. (A) A catalyst does not change AH of the reaction (B) A catalyst changes the equilibrium point (C) Law of mass action was suggested by Le-Chatelier (D) The difference between the energy of reactants and that of the products is the activation energy

Last Answer : (A) A catalyst does not change AH of the reaction

Description : "When a system in equilibrium is subjected to a change in temperature, pressure or concentration, the equilibrium is displaced in a direction which tends to undo the effect of the change." This is ... Chatelier principle (B) Kopp's rule (C) Law of corresponding state (D) Arrhenius hypothesis

Last Answer : (A) Le-Chatelier principle

Description : The compressive strength of cement should not be less than about 110Kg/cm2 after three days & not less than 170Kg/cm2 after seven days. The fineness of an ordinary cement as determined by turbidimetric method should be about __________ cm2 /gm. (A) 800 (B) 1600 (C) 4000 (D) 8500

Last Answer : (B) 1600

Description : For an ordinary Portland cement (A) Residual does not exceed 10% when sieved through IS Sieve No. 9 (B) Soundness varies from 5 to 10 mm (C) Initial setting time is not less than 30 minutes (D) Compressive stress after 7 days, is not less than 175 kg/cm2

Last Answer : (C) Initial setting time is not less than 30 minutes

Description : Soundness test of cement determines (A) Quality of free lime (B) Ultimate strength (C) Durability (D) Initial setting

Last Answer : Answer: Option A

Description : Pick up the correct statement from the following: (A) Plain cement concrete is equally strong in compression as well as in tension (B) Slump test is performed to check concrete strength (C ... D) Fineness modulus is the index number expressing the relative sizes of both coarse and fine aggregates

Last Answer : Option D

Description : For quality control of Portland cement, the test essentially done is (A) Setting time (B) Tensile strength (C) Consistency (D) All the above

Last Answer : D

Description : Strength of concrete increases with (A) Increase in water-cement ratio (B) Increase in fineness of cement (C) Decrease in curing time (D) Decrease in size of aggregate

Last Answer : (B) Increase in fineness of cement

Description : C.R.R.I. charts are used to obtain a relationship between strength of concrete and (A) Water cement ratio (B) Workability (C) Grading of aggregate (D) Fineness modulus

Last Answer : Answer: Option A

Description : Too much fineness of cement (a) Results cracks in concrete (b) Generates greater heat (c) Develops later strength (d) All the above

Last Answer : (d) All the above

Description : Slump cone test is used to determine [ A ] Shrinkage of concrete mix [ B ] Creep of concrete [ C ] Workability of concrete mix [ D ] Soundness of concrete

Last Answer : [ C ] Workability of concrete mix

Description : Unconfmed compressive strength test is (A) Undrained test (B) Drained test (C) Consolidated undrained test (D) Consolidated drained test

Last Answer : (A) Undrained test

Description : The preliminary test is repeated if the difference of compressive strength of three test specimens, exceeds (A) 5 kg/cm2 (B) 8 kg/cm2 (C) 10 kg/cm2 (D) 15 kg/cm2

Last Answer : Answer: Option D

Description : Pick up the correct statement from the following: (A) Acid test is done to find out the weathering quality of stones (B) Attrition test is done to find out the rate of wear of stones which are used ... (C) Crushing test is done to find out the compressive strength of the stone (D) All the above

Last Answer : Answer: Option D

Description : Smith's test of stones is performed to find out (A) The presence of soluble matter of stone (B) The compressive strength of the stone (C) The hardness of the stone (D) The toughness of the stone

Last Answer : Answer: Option A

Description : For performing the compressive strength test of cement, the size of cube mould should be (a) 7.06cm (b)75mm (c)80mm (d)All the above

Last Answer : (a) 7.06cm

Description : The compressive strength an ordinary Portland cement (1:3) after 7 days test should not be less than. (a) 11N/mm2 (b) 17.5 N/mm2 (c) 22 N/mm2 (d) 27.5N/m2

Last Answer : (b) 17.5 N/mm2

Description : In fineness test on cement, residue left on I.S. sieve no.9 shall not exceed __________ by weight of the sample of cement [ A ] 5% [ B ] 10% [ C ] 15% [ D ] 20%

Last Answer : [ B ] 10%

Description : Soundness test of cement is done to determine its a) Durability in seawater b) Free lime content* c) Iron oxide content d) Alumina content

Last Answer : b) Free lime content*

Description : Explain the rebound hammer test procedure and show the relationship between compressive strength and rebound number with hammer horizontal and vertical on dry and wet surface of concrete.

Last Answer : Rebound Hammer Test: i. Initially the plunger of rebound hammer is Kept touching to the target concrete surface ii. Then the tubular casing of hammer is pushed towards concrete, so that the spring gets ... of concrete will be less, But if it is more, then concrete possess sufficient strength.

Description : Explain the laboratory procedure to determine the compressive strength of concrete cubes as per IS-516-1959 with reference to following points: i. Preparation of test specimen ii. Procedure of testing iii. Interpretation of results

Last Answer : Preparation of test specimen: i. Take three cubes of 15 cm sides and apply oil to its inner surface. ii. Prepare the concrete mixture of required grade and fill it in each mould in 3 layers. ... say 23N/mm 2) than the specified grade M20, then that concrete is safe and good for construction.

Description : The slump test of concrete is used to measure its (a) Consistency (b) Mobility (c) Homogeneity (d) All the above

Last Answer : (a) Consistency

Description : Pick up the incorrect definition from the following: (A) Ratio of the compressive strength of unconfined undisturbed soil to that of remoulded soil, is known as the sensitivity of the soil sample (B) The ... content at which a soil flows, is known plastic limit of the soil (D) None of these

Last Answer : Answer: Option D

Description : Sensitivity of a soil can be defined as (A) Percentage of volume change of soil under saturated condition (B) Ratio of compressive strength of unconfined undisturbed soil to that of soil in a remoulded state (C) Ratio of volume of voids to volume of solids (D) None of the above

Last Answer : Answer: Option B

Description : Permissible compressive strength of M 200 concrete grade is (A) 100 kg/cm2 (B) 150 kg/cm2 (C) 200 kg/cm2 (D) 250 kg/cm2

Last Answer : (C) 200 kg/cm2

Description : Permissible compressive strength of M 300 concrete grade is (A) 100 kg/cm2 (B) 150 kg/cm2 (C) 200 kg/cm2 (D) 300 kg/cm2

Last Answer : (D) 300 kg/cm2

Description : The compressive strength of 100 mm cube as compared to 150 mm cube is always (A) Less (B) More (C) Equal (D) None of the above

Last Answer : Answer: Option B

Description : A higher modular ratio shows (A) Higher compressive strength of concrete (B) Lower compressive strength of concrete (C) Higher tensile strength of steel (D) Lower tensile strength of steel

Last Answer : Answer: Option B

Description : Modulus of rupture of concrete is a measure of (A) Flexural tensile strength (B) Direct tensile strength (C) Compressive strength (D) Split tensile strength

Last Answer : Answer: Option A

Description : Permissible compressive strength of M 200 concrete grade is (A) 100 kg/cm2 (B) 150 kg/cm2 (C) 200 kg/cm2 (D) 250 kg/cm2

Last Answer : Answer: Option C

Description : Specified compressive strength of concrete is obtained from cube tests at the end of (A) 3 days (B) 7 days (C) 21 days (D) 28 day

Last Answer : Answer: Option D

Description : According to IS: 4561978, the flexural strength of concrete is (A) Directly proportional to compressive strength (B) Inversely proportional to compressive strength (C) Directly proportional to square root of compressive strength (D) Inversely proportional to square root of compressive strength

Last Answer : Answer: Option C

Description : Permissible compressive strength of M 150 concrete grade is (A) 100 kg/cm2 (B) 150 kg/cm2 (C) 200 kg/cm2 (D) 250 kg/cm2

Last Answer : Answer: Option C

Description : If the average compressive strength is 4000 kg/cm2 and standard deviation is 500, the co-efficient of variation is (A) 10 % (B) 12.5 % (C) 15 % (D) 18.5%

Last Answer : Answer: Option B

Description : Allowable shear strength of concrete, depends upon (A) Shear strength (B) Tensile strength (C) Compressive strength (D) None of these

Last Answer : Answer: Option A

Description : For lime concrete, (A) Slump is 50 to 75 mm (B) Flexural strength at 90 days is 0.2 N/mm2 (C) Compressive strength at 90 days is 1.5 N/mm2 (D) All the above

Last Answer : Answer: Option D

Description : The minimum compressive strength of 1st class bricks should be (A) 75 kg/cm2 (B) 90 kg/cm2 (C) 100 kg/cm2 (D) 120 kg/cm2

Last Answer : Answer: Option C

Description : Pick up the correct statement regarding low heat cement from the following: (A) It possesses less compressive strength (B) Its initial setting time is about one hour (C) Its final setting time is about 10 hours (D) All the above

Last Answer : Answer: Option D