For performing the compressive strength test of cement, the size of cube mould should be
(a) 7.06cm
(b)75mm
(c)80mm
(d)All the above

1 Answer

Answer :

(a) 7.06cm

Related questions

Description : Pick up the incorrect statement from the following. For performing compressive strength test of cement (A) Cement and standard sand mortar are used in the ratio of 1 : 3 (B) Water is added at the ... cm 10 cm is used (D) The prepared moulds are kept in a atmosphere of 50% relative humidity

Last Answer : Answer: Option A

Description : For testing compressive strength of cement, the size of cube used is (A) 50 mm (B) 70.6 mm (C) 100 mm (D) 150 mm

Last Answer : B

Description : The compressive strength an ordinary Portland cement (1:3) after 7 days test should not be less than. (a) 11N/mm2 (b) 17.5 N/mm2 (c) 22 N/mm2 (d) 27.5N/m2

Last Answer : (b) 17.5 N/mm2

Description : Specified compressive strength of concrete is obtained from cube tests at the end of (A) 3 days (B) 7 days (C) 21 days (D) 28 day

Last Answer : Answer: Option D

Description : For determining the compressive strength test on cement is, the percentage amount of water to be added as (Pa = Percentage of water for required consistency) [ A ] 0.25 Pa + 2.5 [ B ] 0.25 Pa + 3.5 [ C ] 0.35 Pa + 2.5 [ D ] 0.35 Pa + 3.5

Last Answer : [ B ] 0.25 Pa + 3.5

Description : According to IS specifications, the compressive strength of ordinary Portland cement after three days should not be less than (A) 7 MPa (B) 11.5 MPa (C) 16 MPa (D) 21 MPa

Last Answer : Answer: Option C

Description : The steel mould used for slump test is in the form of a (a) Cube (b) Cylinder (c) Frustrum of a cone (d) None of these

Last Answer : (c) Frustrum of a cone

Description : The compressive strength of 100 mm cube as compared to 150 mm cube is always (A) Less (B) More (C) Equal (D) None of the above

Last Answer : Answer: Option B

Description : A muff coupling is connecting two shafts. The torque involved is 650N-m. The shaft diameter is 45mm with length and height of the key being 14mm and 80mm respectively. Find the compressive stress induced in the key. a) 70.1 N/mm2 b) 51.6N/mm2 c) 45.5N/mm2 d) None of the listed

Last Answer : b) 51.6N/mm2

Description : Pick up the correct statement regarding low heat cement from the following: (A) It possesses less compressive strength (B) Its initial setting time is about one hour (C) Its final setting time is about 10 hours (D) All the above

Last Answer : Answer: Option D

Description : Le-Chatelier's device is used for determining the (A) Setting time of cement (B) Soundness of cement (C) Tensile strength of cement (D) Compressive strength of cement

Last Answer : Answer: Option B

Description : Soundness of cement is tested by (A) Vicat's apparatus (B) Le-chatelier apparatus (C) Compressive strength testing apparatus (D) None of these

Last Answer : Answer: Option B

Description : For testing compressive and tensile strength of cement, the cement mortar is made by mixing cement and standard sand in the proportions of (A) 1 : 2 (B) 1 : 3 (C) 1 : 4 (D) 1 : 6

Last Answer : Answer: Option B

Description : Which of the following cements is expected to have the highest compressive strength after 3 days (a) Ordinary Portland cement (b) Rapid hardening cement (c) High alumina cement (d) Sulphate resisting cement.

Last Answer : (c) High alumina cement

Description : Minimum compressive strength of cement required at the age of 3 days for ordinary Portland cement of grade 33 is [ A ] 1.15 N/mm2 [ B ] 11.5 N/mm2 [ C ] 2.10 N/mm2 [ D ] 21 N/mm2

Last Answer : [ B ] 11.5 N/mm2

Description : The minimum particle size of fine aggregate is (a) 0.0075mm (b) 0.075mm (c)0.75mm (d)0.95m

Last Answer : (b) 0.075mm

Description : For dam construction the size of aggregates are (a) 40mm (b) 50mm (c) 60mm (d) 75mm

Last Answer : (a) 40mm

Description : Pick up the incorrect statement from the following. While performing preliminary test on concrete (A) Proportions of the material and water should be the same as to be used at the work site (B) ... in air-tight containers (D) Concrete ingredients should be kept at a temperature of 37° 2°C

Last Answer : Answer: Option D

Description : Pick up the incorrect statement from the following: (A) The bottom and top ends of slump mould are parallel to each other (B) The axis of the mould is perpendicular to the end faces (C) The ... clean and free from set cement (D) The mould is in the form of a frustum of hexagonal pyramid

Last Answer : Answer: Option D

Description : For an ordinary Portland cement (A) Residual does not exceed 10% when sieved through IS Sieve No. 9 (B) Soundness varies from 5 to 10 mm (C) Initial setting time is not less than 30 minutes (D) Compressive stress after 7 days, is not less than 175 kg/cm2

Last Answer : (C) Initial setting time is not less than 30 minutes

Description : The compressive strength of cement should not be less than about 110Kg/cm2 after three days & not less than 170Kg/cm2 after seven days. The fineness of an ordinary cement as determined by turbidimetric method should be about __________ cm2 /gm. (A) 800 (B) 1600 (C) 4000 (D) 8500

Last Answer : (B) 1600

Description : Le Chatelier apparatus is used to determine which of the following properties for cement A) Soundness* b) Initial setting time c) Compressive strength d) Tensile strength

Last Answer : A) Soundness*

Description : Explain the procedure for determination of compressive strength of cement in laboratory.

Last Answer : Procedure for determination of compressive strength of cement in laboratory: 1. Take 200 gm cement, 600 gm standard sand and add water ((p/4)+3) % to that of combined weight of cement and sand. ... area of cube in mm2 . 9. Calculate average compressive strength of three test cubes in N/mm2 . 

Description : Unconfmed compressive strength test is (A) Undrained test (B) Drained test (C) Consolidated undrained test (D) Consolidated drained test

Last Answer : (A) Undrained test

Description : Slump test of concrete is a measure of its (A) Consistency (B) Compressive strength (C) Tensile strength (D) Impact value

Last Answer : (A) Consistency

Description : Slump test of concrete is a measure of its (A) Consistency (B) Compressive strength (C) Tensile strength (D) Impact value

Last Answer : (A) Consistency

Description : The preliminary test is repeated if the difference of compressive strength of three test specimens, exceeds (A) 5 kg/cm2 (B) 8 kg/cm2 (C) 10 kg/cm2 (D) 15 kg/cm2

Last Answer : Answer: Option D

Description : Pick up the correct statement from the following: (A) Acid test is done to find out the weathering quality of stones (B) Attrition test is done to find out the rate of wear of stones which are used ... (C) Crushing test is done to find out the compressive strength of the stone (D) All the above

Last Answer : Answer: Option D

Description : Smith's test of stones is performed to find out (A) The presence of soluble matter of stone (B) The compressive strength of the stone (C) The hardness of the stone (D) The toughness of the stone

Last Answer : Answer: Option A

Description : Le-chatelier apparatus is used for [ A ] Fineness test [ B ] Consistency test [ C ] Soundness test [ D ] Compressive strength test

Last Answer : [ C ] Soundness test

Description : Slump test of concrete is a measure of its [ A ] Consistency [ B ] Compressive strength [ C ] Tensile strength [ D ] Impact value

Last Answer : [ A ] Consistency

Description : The aggregate which pass through 75mm IS sieve and entirely retain on 4.75 IS sieve is known as (a) Cyclopean aggregate (b) Coarse aggregate (c)Fine aggregate (d) Aall-in-aggregate

Last Answer : (b) Coarse aggregate

Description : The 28 days cube strength of mass concrete using aggregates of maximum size 5 cm for gravity dams should be (A) Between 150 to 300 kg/cm2 (B) Between 350 to 600 kg/cm2 (C) Between 150 to 500 kg/cm2 (D) Below 200 kg/cm2

Last Answer : Answer: Option D

Description : Generally the strength of concrete is represented by the crushing stress of concrete cube of size [ A ] 50 mm [ B ] 100 mm [ C ] 150 mm [ D ] 250 mm

Last Answer : [ C ] 150 mm

Description : Label size of foreign article is min & postage paid words should not be less than a) 70mm X 100mm & 300sq mm b) 50mm X 80mm & 200sq mm c) 25mm X 50 mm & 100 sq mm d) None of these

Last Answer : a) 70mm X 100mm & 300sq mm

Description : Plain cement concrete is strong in taking (a) Compressive stress. (b) Tensile stress (c) Shear stress (d) All of these

Last Answer : (a) Compressive stress.

Description : Reinforced cement concrete is equally strong in taking (a) Tensile and compressive stress (b) Compressive and shear stresses. (c) Tensile, compressive and shear stresses. (d) Tensile and shear stresses.

Last Answer : (c) Tensile, compressive and shear stresses.

Description : For high degree of workability, the slump value should vary between (a) 0 to 25mm (b) 25 to 50mm (c) 50 to 80mm (d) 80 to 100mm

Last Answer : (d) 80 to 100mm

Description : Strength of concrete increases with (A) Increase in water-cement ratio (B) Increase in fineness of cement (C) Decrease in curing time (D) Decrease in size of aggregate

Last Answer : (B) Increase in fineness of cement

Description : The condition not applicable to water cement ratio law, is (A) Internal moisture conditions on hydration continue till complete strength is gained (B) Concrete specimens may be tested at any temperature (C) Concrete specimens need be of same age (D) Concrete specimens need be of same size

Last Answer : Answer: Option B

Description : For quality control of Portland cement, the test essentially done is (A) Setting time (B) Tensile strength (C) Consistency (D) All the above

Last Answer : D

Description : Workability of concrete mix with low water cement ratio is determined by (A) Tensile strength test (B) Slump test (C) Compaction factor test (D) Flexural strength test

Last Answer : Answer: Option C

Description : Soundness test of cement determines (A) Quality of free lime (B) Ultimate strength (C) Durability (D) Initial setting

Last Answer : Answer: Option A

Description : Pick up the correct statement from the following: (A) Plain cement concrete is equally strong in compression as well as in tension (B) Slump test is performed to check concrete strength (C ... D) Fineness modulus is the index number expressing the relative sizes of both coarse and fine aggregates

Last Answer : Option D

Description : Workability of concrete mix with low water cement ratio is determined by [ A ] Tensile strength test [ B ] Slump cone test [ C ] Compaction factor test [ D ] Flexural strength test

Last Answer : [ C ] Compaction factor test

Description : The size of mould for bricks, is generally kept (A) A little large to specified size (B) A little small to specified size (C) Equal to specified size (D) 10% larger than specified size

Last Answer : Answer: Option A

Description : The internal size of mould used in brick preparation is (A) Equal to the size of a fully burnt brick (B) Smaller than the size of a fully burnt brick (C) Greater than the size of a fully burnt brick (D) None of the above

Last Answer : Answer: Option C

Description : The top diameter, bottom diameter and height of the mould used for slump test are (a) 100mm, 200mm, 300mm (b) 200mm,100mm,300mm (c) 200mm,300mm,100mm (d) 100mm,300mm,200mm

Last Answer : (a) 100mm, 200mm, 300mm

Description : Explain the rebound hammer test procedure and show the relationship between compressive strength and rebound number with hammer horizontal and vertical on dry and wet surface of concrete.

Last Answer : Rebound Hammer Test: i. Initially the plunger of rebound hammer is Kept touching to the target concrete surface ii. Then the tubular casing of hammer is pushed towards concrete, so that the spring gets ... of concrete will be less, But if it is more, then concrete possess sufficient strength.

Description : Explain the laboratory procedure to determine the compressive strength of concrete cubes as per IS-516-1959 with reference to following points: i. Preparation of test specimen ii. Procedure of testing iii. Interpretation of results

Last Answer : Preparation of test specimen: i. Take three cubes of 15 cm sides and apply oil to its inner surface. ii. Prepare the concrete mixture of required grade and fill it in each mould in 3 layers. ... say 23N/mm 2) than the specified grade M20, then that concrete is safe and good for construction.